Staff.

LBTO: Josh, Olga, Alex ,Juan Carlos

Observer:

Forecast.

forecast_20230604_0.png

forecast_20230604_1.png

forecast_20230604_2.png

Summary.

ECD Night. AO scheduled from 09 to 10 PM (local time).

Night log

https://docs.google.com/document/d/12EHuf9fZKcKRC_w3WwaU-lT09QIJDZQ4m3cNMLDoPuY/edit

Details.

PSF morphology.

LUCI_AO_PSFmorphology_May.xml

Targets:

target_visibility_20230604.png

Targets:

#1

RA dms 11:03:40.9551715959
DEC hms +32:53:14.846403816
Proper motions mas/yr : 13.421 52.872

#2

The AO star is
Gaia DR3 1255480105251005568
14 19 02.1560802966 +24 06 12.233466122
Proper motions mas/yr : 13.318 -9.521

#3

Gaia DR3 1328059413265271680
16 41 46.6346814603 +36 28 20.200750347
Proper motions mas/yr : -2.868 -2.69

05:50PM

Power on WFS.

baysde stageX timeout.

  • Power cycle the 24v.
OK

OCAM not live.
  • reconfgure ocam2k from the wfs control gui.
  • reported an error with the masterdiagnostic.
error1_20230605.png
  • the ccd47 came not live.
  • power cycle bcu2k
  • reconfigure ocam 1x1cropped from HW gui
  • ocam live.
ccd47 not live.
  • reconfigure ccd4 from HW gui
  • ccd47 live.
saved ocam frames.

TN:2023060_5012911

07:40PM

OPen telescope.

clouds.

allsky_20230605_0.png

07:52pm

telescope closed

cloudy

waiting.....

08:40pm

open

still clouds.

allsky-2_20230605.png

Starting with collimation,field aberrations.

nudge predictor.

[lbto@obs2 ObserverSupport ]$ ./nudgepredict.py -d 20230605 -e 13 -b 12
./nudgepredict.py script version of 31-May-2023
5192726399.0 end MJD sec for the end of this UT day
60100 end MJD day
5192686800.0 end MJD sec corrected for endhour 13.0
5192643600.0 start MJD sec using backhour 12.0
20230605 is the day to be plotted.
1.0 start hour using backhour 12.0 end hour 13.0
These UT start times will have a nudge if the telescope is tracking.
01:16:10
01:50:18
02:24:26
02:58:34
03:32:42
04:06:50
04:40:58
05:15:06
05:49:14
06:23:22
06:57:30
07:31:38
08:05:46
08:39:54
09:14:02
09:48:10
10:22:18
10:56:26
11:30:34
12:04:42
12:38:50

10:11PM

switch to Luci DX.

Dimm not running, it is not connected.

on Jun 5 05:25:14.008 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[8283]
Mon Jun 5 05:25:17.970 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[8284] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0494586[-0.0494586],roy:0.0349557,mag:10.66,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Jun 5 05:25:17.988 2023 aos.info - WFS source set to: FLAOWFS
Mon Jun 5 05:25:18.685 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

not star in the cd47 or GCS.

getting cloudy.

pointing Arthur and the extinsion is too high, the star is visible in the guider and disappear, this is not quite good for the AO....

waiting....IDLE..

Stop AO

warm OCAM.

try again after midnight.....

01:50 switch to luci

Try....AO.

sky much better. some scarce clouds passing.

Mon Jun 5 08:54:04.460 2023 aos.Stop{FLAO}.started - Stop{FLAO}[8304] (msg:Starting Preset)
Mon Jun 5 08:54:04.473 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[8304]
Mon Jun 5 08:54:08.053 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[8305] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.114193[-0.114193],roy:-0.00406932,mag:11.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

sArbitrator_133248|DEB| 393|2023-06-05 08:58:45.698937| MAIN > Estimated magnitude from camera: 12.66
WfsArbitrator_133248|INF| 394|2023-06-05 08:58:45.698977| MAIN > Actual magnitude 12.7 - Recomputing AO params

optimizegn

TN:20230605091148,_091222

n30 mask alignment , luci script in pause

loop open./reclose

optimize

luci setup in integrated..

luci2.20230605.0013.fits

_092008,_092025

_092124,_092146,_092205,_092227(pause)

_092255,_092311,_092326 luci.0016

_092418,_092442,_092459 luci.0017

-092543,_092604,_092623 luci.0018

_092701,_092718,_092736 luci.0019

_092831,_092852,_092913 luci.0020

_092950,_093005,_093022 luci.0021

_093112,_093129,_093145 luci.0022

_093529,_luci.0024

guider seeing 1.1-1.07"

-093636 luci.0023

_093832,_093848 luci.0025

-093922,_093938,_093953.luci0026

_094044,_094109,_094217,luci.0027

_094208,_094225,_094240 luci0028

-094325,_094355,_094411.luci0029

_094450,_094516,_094535 luci0030

_094618,_094642,_094656 luci0031

_094741,_094908 luci0032 (nudge........)

loop open nudge relocse

optimize:_094945

_095248,_095312,(pausae) luci0033

_095338,_095354,_095417 luci0034

Stop.

02:58am

Change to MODS

Field aberration data acq.

OCAM safe.

-- JuanCarlosGuerra - 04 Jun 2023
Topic revision: r4 - 05 Jun 2023, JuanCarlosGuerra