Staff.

LBTO: Steve, Jenny, Alex and Juan Carlos

Observer. Enrico (remote Italy)

Forecast.

forecast-20230506_0.png

forecast_20230506_1.png

forecast_20230506_2.png

Details.

05:15PM

WFS power on.

OCAM ok

It was a power bump in the afternoon.

Checking the adsec in rest there is one actuator#263 that shows the large position of 30um at the edge.

act-20230506.png

act-263-20230506.png

Nudge forecast.

[lbto@obs1 ObserverSupport ]$ ./nudgepredict.py -d 20230507 -e 12 -b 12
./nudgepredict.py script version of 28-Mar-2022
5190220799.0 end MJD sec for the end of this UT day
60071 end MJD day
5190177600.0 end MJD sec corrected for endhour 12.0
5190134400.0 start MJD sec using backhour 12.0
20230507 is the day to be plotted.
0.0 start hour using backhour 12.0 end hour 12.0
These UT start times will have a nudge if the telescope is tracking.
00:22:50
00:56:58
01:31:06
02:05:14
02:39:22
03:13:30
03:47:38
04:21:46
04:55:54
05:30:02
06:04:10
06:38:18
07:12:26
07:46:34
08:20:42
08:54:50
09:28:58
10:03:06
10:37:14
11:11:22
11:45:30


Wind high at South. restricted pointing in South.

07:34PM

First preset.

Sun May 7 02:34:27.622 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3347] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0114369[0.0114369],roy:0.0195629,mag:8.32,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun May 7 02:34:27.635 2023 aos.info - WFS source set to: FLAOWFS
  • luci filter#2 error.
  • preset canceled due to luci issue.
Seeing looks good stable below 1arcsec.

20230506_collstart1.png

next nudge 03:13:30.

windspeed_adsec.png

07:48PM
  • Still working on to fix Luci issue.
03:55.690 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3351] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.032156[0.032156],roy:0.0188753,mag:8.32,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize: 20230507_025704

code error#2

codeerror_2_20230506.png

TN:_030051,030302

l;uci: subframe 256,256

50 frames

_030339,_030540(no dimm),_030649(no dimm),_030749,_030822,_030857,_030929,_031022(nodimm),_031127

WfsArbitrator _74817|INF| 502|2023-05-07 03:10:24.022508| MAIN > saveIrtcInternal(): starting measure, 50 frames
WfsArbitrator_74816|WAR| 1192|2023-05-07 03:10:24.607072| MAIN > OCAM Bad Frames/Slopes Warning, code 128
WfsArbitrator_74816|WAR| 1193|2023-05-07 03:10:24.607133| MAIN > OCAM Warning Description: Code 128 - Noisy Octants: Pixel RMS in external octants is high
WfsArbitrator_74816|WAR| 1194|2023-05-07 03:10:24.607157| MAIN > OCAM Suggested action to recover: No action required; no impact on performance is expected
20230705 03:10:24.6076 Warning: Warning state caused by Bad Frames or Slopes, CODE:128 - No Action required
WfsArbitrator_74817|DEB| 503|2023-05-07 03:10:50.997095| MAIN > getSetupFits(): fits header create

loop pause.

nudge happening.

next nudge: 03:47:38

luci dark: 20230507.0019,0020.

TN+luci:_031618,_031658,_031733,_031831,_031916

08:19

seeing :1.5 going up.

ncpaon

WfsArbitrator _74817|DEB| 594|2023-05-07 03:20:07.126790| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 67.335300000000004, 0)
WfsArbitrator_74817|DEB| 595|2023-05-07 03:20:07.175076| MAIN > arbFunc updateNcpaInternal done

TN+luci:_032012,_32048,_032141

offset to recenter PSF in center of subframe.

08:24

seeing 1"

TN+luci: _032717,_032756(no dimm),_032833,_032914

ncpa off.

TN+luci:_033006,_033052,_033130,_033210

03:33

seeing stable ~1"

Sun May 7 03:34:22.452 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[3368]
Sun May 7 03:34:27.111 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3369] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0938793[-0.0938793],roy:-0.0866928,mag:9.52,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize:_034036

1.94,0.4,0.55

seeing going up from 1 to 1.5"

double star.

TN:_034304,_034431,_034453,_034531,_

TN+Luci:_034756,_034842,_034923,_

sky.

luci sky:0049,0050

next nudge:04:21:46

Sun May 7 03:53:13.984 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3378] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0239259[0.0239259],roy:-0.141405,mag:9.48,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • Optimize:_035757
  • 2.06,0.38,0.58
08:59
  • seeing 1.3
  • recenter PSF.
WfsArbitrator _74817|DEB| 1246|2023-05-07 04:01:56.378776| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', -0.061537599999999998, 0.26881500000000003, True)
WfsArbitrator_74817|INF| 1247|2023-05-07 04:01:56.379040| MAIN > offsetXY(): starting offset of -0.063, 0.269 mm
  • tn:_040324,_040342,_040358,_
  • luci 1 sec , frames 50, 256,256
  • TN+luci:_040530,_040653,_040805,_040956,_041104,_041220
  • rot 188 good PSF
969954D4-1B93-4A5E-B550-F8731778E6CA.png

ncpa on

ator_74817|DEB| 1311|2023-05-07 04:13:51.275083| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 183.34899999999999, 0)
WfsArbitrator_74817|DEB| 1312|2023-05-07 04:13:51.323620| MAIN > arbFunc updateNcpaInternal done.
  • TN+luci:_041403,_041511,_041652,_041801,_041917,_042035,_042212
  • offset
  • sky
  • luci sky :0067,0068

next nudge: 04:55:54

Sun May 7 04:27:23.735 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3390] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.00514149[0.00514149],roy:-0.0918671,mag:10.68,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

1548|2023-05-07 04:29:29.928175| MAIN > arbFunc doCloseLoop done.
WfsArbitrator_74816|WAR| 3247|2023-05-07 04:29:32.998176| MAIN > OCAM Bad Frames/Slopes Warning, code 128
WfsArbitrator_74816|WAR| 3248|2023-05-07 04:29:32.998228| MAIN > OCAM Warning Description: Code 128 - Noisy Octants: Pixel RMS in external octants is high
WfsArbitrator_74816|WAR| 3249|2023-05-07 04:29:32.998261| MAIN > OCAM Suggested action to recover: No action required; no impact on performance is expected
20230705 04:29:32.9985 Warning: Warning state caused by Bad Frames or Slopes, CODE:128 - No Action require
  • Optimize:_043046,
  • TN:_043650,_043711,_043724,_043737,_043750,_043830
  • seeing 1"
  • luci H, exp 0 frames 50
  • TN+luci:043928,_044006,_044109,_044146,_044240,_044316
ncpaon

fsArbitrator_74817|DEB| 1708|2023-05-07 04:44:17.409604| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 191.89599999999999, 0)
WfsArbitrator_74817|DEB| 1709|2023-05-07 04:44:17.423151| MAIN > arbFunc updateNcpaInternal done.

TN+luci:_044424,_044500,_044546,_044620,_044654,_044729,

Doug connected, there is a new file for ncpa limited to 40nmrms wavefront.

sky

0084,0085

gl;itch in Gopt, plot looks flat.

TN:_045131

continous dumping.

fastdiagn_136638 |WAR| 4082005|2023-05-07 05:23:05.395801| FUNCTWARNING > FunctWarning CHDISTRMS-0070 0.00917155
fastdiagn_136638 |ERR| 4082006|2023-05-07 05:23:05.396680| FUNCTALARM > FunctAlarm CHCURRRMS-0184 -5.6833e-14
fastdiagn_136638 |INF| 4082007|2023-05-07 05:23:05.397241| SWITCH > /home/aoeng/soul/aolog/2023/05/07/fastdiagn.R.202305070002.log

gopt to zero.

took screenshot.

297|2023-05-07 04:50:58.926602| MAIN > Tracknum: 20230507_250000 demodDelta/demodCmd: 1.08e-08/1.22e-08 gopt: 0.392
python_79904 |INF| 298|2023-05-07 04:51:58.538105| MAIN > TERMINATE received. Its TimeToDie.
python_49980 |DEB| 1|2023-05-07 04:52:16.130519| MAIN > Connected as gopt.R
python_49980 |INF| 2|2023-05-07 04:53:16.593578| MAIN > TERMINATE received. Its TimeToDie.
python_56312 |DEB| 1|2023-05-07 04:53:32.893388| MAIN > Connected as gopt.R
python_56312 |INF| 2|2023-05-07 04:53:38.896916| MAIN > Closed loop iterations=1, waiting for the next one
python_56312 |INF| 3|2023-05-07 04:53:43.003632| MAIN > Tracknum: 20230507_250000 demodDelta/demodCmd: 1.21e-08/1.23e-08 gopt: 0.390

restablished by iteself.

Sun May 7 04:55:48.291 2023 aos.info - HO offload command end
Sun May 7 04:55:51.918 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3400] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0699066[-0.0699066],roy:-0.0408267,mag:12.11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optmize:_050035

next nudge:05:30:02

  • TN:_050211,_050229,_050241,_050314(afteroffset),_050334,_050459
  • TN+Luci:_050559,_050752,_050910,_051037,_051201,_051316
ncpaon

3-05-07 05:14:30.128913| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 249.47900000000001, 0)
WfsArbitrator_74817|DEB| 2140|2023-05-07 05:14:30.170012| MAIN > arbFunc updateNcpaInternal done.
  • tn+luci:_051447,_051602,_051720,_051835,_052004,_052128
  • offset
  • sky:0102,0103
Sun May 7 05:26:01.695 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3410] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0839461[-0.0839461],roy:-0.115117,mag:12.06,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize:053019

continous dumping again.

84B1A503-0B41-424A-A746-0074B487E23F.png

next nudge:06:04:10

TN:_053305,_053320,_053356,_053412,_

luci exp 0 frames 50

TN+luci:_053553,_053641,_053735,_053810,_055849,_053929.

offset

luci:0114,0115

TSS activated. wind speed 5m/s

ncpa on

Arbitrator_74817|DEB| 2548|2023-05-07 05:43:28.056224| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 225.19399999999999, 0)
WfsArbitrator_74817|DEB| 2549|2023-05-07 05:43:28.129222| MAIN > arbFunc updateNcpaInternal done.

TN+luci:_054342,_054437,_054517,_054558(tss activate),_054635,_054719,_

seeing 1"

Sun May 7 05:49:47.367 2023 aos.info - HO offload command end
Sun May 7 05:49:50.742 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3425] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0372183[0.0372183],roy:-0.154456,mag:13.49,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize:_055320

TN:_055501,_055520,_055542,055623

TN+luci:_055639,_055726,_055759,_055846,_055923,_060003

offset

sky:0131,0132

ncpaon

loop pause wating for the nudge

TN+Luci:_060439,_060517,_060552,_060633,_060706,_060747

next nudge: 06:38:18


Sun May 7 06:10:51.122 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[3440] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.125735[-0.125735],roy:-0.0667899,mag:14.26,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

mag14.6

optmize:_061518

5.28,0.72,0.10

11:16

seeing 1.1

TN:_061730,_061743,_061743,_061825,_061840,_061941

luci h, exp10 frames 15

TN+luci:_062028,_062321

stop dumping continously.

11:24 no star in the pyramid.

????

force to open the loop using the variable nspector.

Shell was still set...

resend the preset again.

opimize:_063212

TN:063407

TN+luci:_063441

pause for nudge

next nudge:07:12:26



TN+luci:_063840,_064148,_064437,064728,,_065025

11:44

seeing 1"

11:48

seeing up to 1.5"coming down again.

TT jitter 0.015arcsec

offset

sky:0153,0154

wind gust above limit.

11:57PM

closing dome... due to high wind.

stop for soul-luciDX and hand over to LBTI seconds hal

-- JuanCarlosGuerra - 07 May 2023
Topic revision: r3 - 08 May 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.