DX NCPA

17:03
  • Found the source, doing a preset.
  • -2.7, -1.6, 1.29, -169, -232, 0
17:46
  • About to start "psf_collect.py"
  • ~/doug/ncpa_collect/
  • ./psf_collect.py -rot=[360,0,-30] -modes[5.6.7] -zern[2,15] -set=20230505_ncpa
  • Moving to rotator angle 360
    0.32 0.0 0.0
    irc RotServicePosition 360.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_175635 LuciName luci2.20230505.0012.fits

    Moving to rotator angle 330
    0.32 0.0 0.0
    irc RotServicePosition 330.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_175751 LuciName luci2.20230505.0013.fits

    Moving to rotator angle 300
    0.32 0.0 0.0
    irc RotServicePosition 300.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_175904 LuciName luci2.20230505.0014.fits

    Moving to rotator angle 270
    0.32 0.0 0.0
    irc RotServicePosition 270.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180022 LuciName luci2.20230505.0015.fits

    Moving to rotator angle 240
    0.32 0.0 0.0
    irc RotServicePosition 240.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180134 LuciName luci2.20230505.0016.fits

    Moving to rotator angle 210
    0.32 0.0 0.0
    irc RotServicePosition 210.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180249 LuciName luci2.20230505.0017.fits

    Moving to rotator angle 180
    0.32 0.0 0.0
    irc RotServicePosition 180.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
  • Moving to rotator angle 150
    0.32 0.0 0.0
    irc RotServicePosition 150.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180515 LuciName luci2.20230505.0019.fits

    Moving to rotator angle 120
    0.32 0.0 0.0
    irc RotServicePosition 120.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180628 LuciName luci2.20230505.0020.fits

    Moving to rotator angle 90
    0.32 0.0 0.0
    irc RotServicePosition 90.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180744 LuciName luci2.20230505.0021.fits

    Moving to rotator angle 60
    0.32 0.0 0.0
    irc RotServicePosition 60.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_180854 LuciName luci2.20230505.0022.fits

    Moving to rotator angle 30
    0.32 0.0 0.0
    irc RotServicePosition 30.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_181009 LuciName luci2.20230505.0023.fits

    Moving to rotator angle 0
    0.32 0.0 0.0
    irc RotServicePosition 0.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_181122 LuciName luci2.20230505.0024.fits

    List of log names written to 20230505_ncpa/check.log
  • Dark Frame MAIN > saveCalibFile(): saved as 20230505_181514
  • It's also luci image #5
  • [AOeng@soul-dxwfs ncpa_collect]$ ./psf_collect.py -rot=[0,360,30] -set=20230505_ncpa_2
    parts ['-rot', '[0,360,30]']
    parts ['-set', '20230505_ncpa_2']

    => Command line arguements processed

    => NCPA Check Parameters:
    Rotation Parmeters: Angles 0 -> 360 steps of 30
    Zernike Data to Collect: Modes [5, 6], 2 steps (+-) of 15
    Test Mode: False
    Set Name: 20230505_ncpa_2
    Log List: 20230505_ncpa_2/check.log

    => Are these Check parameters correct?
    Yes: press carriage return
    No: press any character and carriage return
    =>
    => Yes

    Moving to rotator angle 0
    0.32 0.0 0.0
    irc RotServicePosition 0.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_181944 LuciName luci2.20230505.0026.fits

    Moving to rotator angle 30
    0.32 0.0 0.0
    irc RotServicePosition 30.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182055 LuciName luci2.20230505.0027.fits

    Moving to rotator angle 60
    0.32 0.0 0.0
    irc RotServicePosition 60.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182206 LuciName luci2.20230505.0028.fits

    Moving to rotator angle 90
    0.32 0.0 0.0
    irc RotServicePosition 90.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182322 LuciName luci2.20230505.0029.fits

    Moving to rotator angle 120
    0.32 0.0 0.0
    irc RotServicePosition 120.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182432 LuciName luci2.20230505.0030.fits

    Moving to rotator angle 150
    0.32 0.0 0.0
    irc RotServicePosition 150.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182547 LuciName luci2.20230505.0031.fits

    Moving to rotator angle 180
    0.32 0.0 0.0
    irc RotServicePosition 180.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182659 LuciName luci2.20230505.0032.fits

    Moving to rotator angle 210
    0.32 0.0 0.0
  • irc RotServicePosition 210.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182816 LuciName luci2.20230505.0033.fits

    Moving to rotator angle 240
    0.32 0.0 0.0
    irc RotServicePosition 240.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_182928 LuciName luci2.20230505.0034.fits

    Moving to rotator angle 270
    0.32 0.0 0.0
    irc RotServicePosition 270.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_183047 LuciName luci2.20230505.0035.fits

    Moving to rotator angle 300
    0.32 0.0 0.0
    irc RotServicePosition 300.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_183158 LuciName luci2.20230505.0036.fits

    Moving to rotator angle 330
    0.32 0.0 0.0
    irc RotServicePosition 330.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_183315 LuciName luci2.20230505.0037.fits

    Moving to rotator angle 360
    0.32 0.0 0.0
    irc RotServicePosition 360.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.64 0.15 0.194372
    Set 0 Tracknum 20230505_183425 LuciName luci2.20230505.0038.fits

    List of log names written to 20230505_ncpa_2/check.log
  • Moving to rotator angle 360
    0.462848 0.0 0.0
    irc RotServicePosition 360.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191039 LuciName luci2.20230506.0001.fits

    Moving to rotator angle 330
    0.462848 0.0 0.0
    irc RotServicePosition 330.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191149 LuciName luci2.20230506.0002.fits

    Moving to rotator angle 300
    0.462848 0.0 0.0
    irc RotServicePosition 300.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191300 LuciName luci2.20230506.0003.fits

    Moving to rotator angle 270
    0.462848 0.0 0.0
    irc RotServicePosition 270.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191417 LuciName luci2.20230506.0004.fits

    Moving to rotator angle 240
    0.462848 0.0 0.0
    irc RotServicePosition 240.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191527 LuciName luci2.20230506.0005.fits

    Moving to rotator angle 210
    0.462848 0.0 0.0
    irc RotServicePosition 210.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191653 LuciName luci2.20230506.0006.fits

    Moving to rotator angle 180
    0.462848 0.0 0.0
    irc RotServicePosition 180.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191804 LuciName luci2.20230506.0007.fits

    Moving to rotator angle 150
    0.462848 0.0 0.0
    irc RotServicePosition 150.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
  • 0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_191920 LuciName luci2.20230506.0008.fits

    Moving to rotator angle 120
    0.462848 0.0 0.0
    irc RotServicePosition 120.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_192030 LuciName luci2.20230506.0009.fits

    Moving to rotator angle 90
    0.462848 0.0 0.0
    irc RotServicePosition 90.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_192145 LuciName luci2.20230506.0010.fits

    Moving to rotator angle 60
    0.462848 0.0 0.0
    irc RotServicePosition 60.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_192255 LuciName luci2.20230506.0011.fits

    Moving to rotator angle 30
    0.462848 0.0 0.0
    irc RotServicePosition 30.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_192410 LuciName luci2.20230506.0012.fits

    Moving to rotator angle 0
    0.462848 0.0 0.0
    irc RotServicePosition 0.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.925696 0.122447 0.157763
    Set 0 Tracknum 20230505_192520 LuciName luci2.20230506.0013.fits

    List of log names written to 20230505_ncpa_3/check.log

It looks like w had the wrong filter in place for elab to work. I took a new dark with the H band filter and restarted.
  • Dark is #24
  • [AOeng@soul-dxwfs ncpa_collect]$ ./psf_collect.py -rot=[0,360,30] -set=20230505_ncpa_4
    parts ['-rot', '[0,360,30]']
    parts ['-set', '20230505_ncpa_4']

    => Command line arguements processed

    => NCPA Check Parameters:
    Rotation Parmeters: Angles 0 -> 360 steps of 30
    Zernike Data to Collect: Modes [5, 6], 2 steps (+-) of 15
    Test Mode: False
    Set Name: 20230505_ncpa_4
    Log List: 20230505_ncpa_4/check.log

    => Are these Check parameters correct?
    Yes: press carriage return
    No: press any character and carriage return
    =>
    => Yes

    Moving to rotator angle 0
    0.271526 0.0 0.0
    irc RotServicePosition 0.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_195859 LuciName luci2.20230506.0025.fits

    Moving to rotator angle 30
    0.271526 0.0 0.0
    irc RotServicePosition 30.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200016 LuciName luci2.20230506.0026.fits

    Moving to rotator angle 60
    0.271526 0.0 0.0
    irc RotServicePosition 60.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200129 LuciName luci2.20230506.0027.fits

    Moving to rotator angle 90
    0.271526 0.0 0.0
    irc RotServicePosition 90.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200246 LuciName luci2.20230506.0028.fits

    Moving to rotator angle 120
    0.271526 0.0 0.0
    irc RotServicePosition 120.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200359 LuciName luci2.20230506.0029.fits

    Moving to rotator angle 150
    0.271526 0.0 0.0
    irc RotServicePosition 150.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
  • 0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200516 LuciName luci2.20230506.0030.fits

    Moving to rotator angle 180
    0.271526 0.0 0.0
    irc RotServicePosition 180.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200630 LuciName luci2.20230506.0031.fits

    Moving to rotator angle 210
    0.271526 0.0 0.0
    irc RotServicePosition 210.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200746 LuciName luci2.20230506.0032.fits

    Moving to rotator angle 240
    0.271526 0.0 0.0
    irc RotServicePosition 240.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_200900 LuciName luci2.20230506.0033.fits

    Moving to rotator angle 270
    0.271526 0.0 0.0
    irc RotServicePosition 270.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_201018 LuciName luci2.20230506.0034.fits

    Moving to rotator angle 300
    0.271526 0.0 0.0
    irc RotServicePosition 300.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_201129 LuciName luci2.20230506.0035.fits

    Moving to rotator angle 330
    0.271526 0.0 0.0
    irc RotServicePosition 330.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_201248 LuciName luci2.20230506.0036.fits

    Moving to rotator angle 360
    0.271526 0.0 0.0
    irc RotServicePosition 360.000000 right
    Resmsg[0] = RotServicePosition result status: OK
    Resmsg[1] = OK
    ----------------------------------------------
    0.543053 0.0543053 0.0271528
    Set 0 Tracknum 20230505_201400 LuciName luci2.20230506.0037.fits

    List of log names written to 20230505_ncpa_4/check.log
TrackNo RefStar Mag El Wind DIMM/Corrected/OL/Disturb Rec bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM [max,min] (mas) filter exp #frames disturb SN skip notes
20230505_195859 ??? 10.8 90 9 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.5 0.57 OFF 38.7 -NaN (1646 nm) [130, 54] clear H 20000 1 ON NO 0  
20230505_200016 ??? 10.8 90 12 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.7 0.60 OFF 48.8 -NaN (1646 nm) [59, 42] clear H 20000 1 ON NO 0  
20230505_200129 ??? 10.8 90 11 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.7 0.59 OFF 72.9 -NaN (1646 nm) [42, 35] clear H 20000 1 ON NO 0  
20230505_200246 ??? 10.8 90 10 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.60 OFF 71.9 -NaN (1646 nm) [42, 37] clear H 20000 1 ON NO 0  
20230505_200359 ??? 10.8 90 10 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.60 OFF 51.6 -NaN (1646 nm) [61, 41] clear H 20000 1 ON NO 0  
20230505_200516 ??? 10.8 90 5 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.59 OFF 62.4 -NaN (1646 nm) [47, 37] clear H 20000 1 ON NO 0 - Background correction failed
20230505_200630 ??? 10.8 90 10 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.60 OFF 60.0 -NaN (1646 nm) [42, 39] clear H 20000 1 ON NO 0  
20230505_200746 ??? 10.8 90 6 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.59 OFF 66.1 -NaN (1646 nm) [40, 37] clear H 20000 1 ON NO 0 - SR may be in error
20230505_200900 ??? 10.8 90 8 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.58 OFF 59.2 -NaN (1646 nm) [44, 43] clear H 20000 1 ON NO 0 - Background correction failed
20230505_201018 ??? 10.8 90 5 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.6 0.59 OFF 74.4 -NaN (1646 nm) [40, 37] clear H 20000 1 ON NO 0 - Background correction failed   20230505_201129 ??? 10.8 90 7 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.5 0.59 OFF 79.8 -NaN (1646 nm) [39, 37] clear H 20000 1 ON NO 0 - SR may be in error
20230505_201248 ??? 10.8 90 9 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.5 0.56 OFF 75.6 -NaN (1646 nm) [40, 37] clear H 20000 1 ON NO 0  
20230505_201400 ??? 10.8 90 5 NaN NaN -1.00 0.00 000501 1 501 1571 600 0.5 0.1 0.0 3 7.5 0.58 OFF 43.4 -NaN (1646 nm) [58, 50] clear H 20000 1 ON NO 0 - SR may be in error
-- GregoryTaylor - 05 May 2023
Topic revision: r1 - 05 May 2023, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback