09:00

Power on DX.

Ocam OK

Power on SX

Ocam OK

-rw-rw-r--. 1 AOeng AOeng 7731 Feb 21 11:30 table_LUCIFER_ACE-AO_20230221_500m_TESTING01.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 21 11:53 table_LUCIFER_ACE-AO_20230221_500m_TESTING02.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 22 08:38 table_LUCIFER_ACE-AO_20230222_500m_TESTING01.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 22 09:35 table_LUCIFER_ACE-AO_20230222_500m_TESTING02.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 23 08:10 table_LUCIFER_ACE-AO_20230223_500m_TESTING01.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 23 10:21 table_LUCIFER_ACE-AO_20230223_500m_v01.txt
lrwxrwxrwx. 1 AOeng AOeng 42 Feb 23 10:29 table_LUCIFER_ACE-AO.txt~ -> table_LUCIFER_ACE-AO_20230223_500m_v01.txt
-rw-rw-r--. 1 AOeng AOeng 7731 Feb 23 12:12 table_LUCIFER_ACE-AO_20230223_500m_TESTING02.txt
-rw-rw-r--. 1 AOeng AOeng 7324 Feb 23 12:31 table_LUCIFER_ACE-AO_20230223_500m_v02.txt
-rw-r--r--. 1 AOeng AOeng 5558 Mar 6 03:07 table_LUCIFER_TTM-AO.txt.esm.20230201
-rw-rw-r--. 1 AOeng AOeng 7403 Apr 3 08:54 table_LUCIFER_ACE-AO_20230403_500m_v01.txt
lrwxrwxrwx. 1 AOeng AOeng 42 Apr 3 08:56 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO_20230403_500m_v01.txt
-rw-rw-r--. 1 AOeng AOeng 7403 Apr 3 12:01 table_LUCIFER_ACE-AO_20230403_500m_v02.txt

Working AO table:table_LUCIFER_ACE-AO_20230403_500m_v02.txt

change link.

test preset DX

e Apr 25 16:36:39.132 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2698] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 16:36:39.183 2023 aos.info - WFS source set to: FLAOWFS

Tue Apr 25 16:39:23.071 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2699] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 16:39:23.089 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 16:39:23.126 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

center pupil.

processes running ok, pupils flat and when loop open shell ripped.

adsc_stop/start

Xinayu and Guido wants to check the adsec.

Not clue why the shell ripped, further investigaion on oging..

09:50am

Fabio connected Zoom. there is not changes for the deploy of sw. deployed version in the WFS:

Currently running: master-and-fwFix (soul)
Available versions in /home/AOeng/soul:
master-and-fwFix
stable

10:10 Pause DX

10:38am

Tue Apr 25 17:38:20.266 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2701] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 17:38:20.283 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 17:38:20.322 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1700.00_sd3892.fits

TN+Luci:20230425_174801,_175105,_175138,_

dark: luci2.20230425.0113,0114.fits

TN+luci:_175344,_175409

ncpaON

TN+luci:_175441,_175505,_175530

stopAO

ocam not live.

not error WFs master

sent preset OK.

bin2

Tue Apr 25 17:59:31.105 2023 aos.PresetAO{FLAO}.complete - PresetAO{FLAO}[2707] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:999 mag:0 nBins:2 nModes:251 r0:nan snMode:0 strehl:0 ttMod:0
Tue Apr 25 18:02:10.434 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2708] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:13,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 18:02:10.454 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 18:02:10.500 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

shutter 120 mag 11.5

shutter 100 mag 13

shutter 90 14.8

shutter 80 mag 16.6

optimize:20230425_180628

TN+luci:_180839,_181034,_181103

ncpaon

TN+luci:_181214,_181412,_181500

IFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:13,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 18:16:24.578 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 18:16:24.627 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq900.00_sd3892.fits
Tue Apr 25 18:16:25.203 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize:_181956

TN+luci:_182127,_182535,_182610

ncpaon

TN+luci:_182649,_182857,_182940

bin3


Tue Apr 25 18:33:04.488 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 18:33:04.609 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits
Tue Apr 25 18:33:05.191 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

shutter 90 mag 14.8

optimize:_183702

change luci exp5 iter 3 filter J

TN+luci:_184718,_184757,_184832

ncpaon

TN+luci:_184832,_185042,_185119

dark:uci2.20230425.0142,0143.fits

bin4

Tue Apr 25 18:54:07.206 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[2721]
Tue Apr 25 18:56:08.286 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2722] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 18:56:08.302 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 18:56:08.418 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits

optimze:_185941,

TN+luci:_190311,_190423,_190549,_191323,

modalSr:18

dark:luci2.20230426.0007.fits0008

shutter 74 magt 17.8

Tue Apr 25 19:16:14.330 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[2729] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:17.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 19:16:14.346 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 19:16:14.395 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits

optimize:_192100

skip frame open loop.

_192225

second pass failed.

manual tt and ho1:

_192504

optimize:192614,_

change mag to 16.8

optimize:_192827

3.24,1.41,0.10

gopt.

1 |DEB| 1635|2023-04-25 19:31:04.798666| MAIN > arbFunc startGoptInternal (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_1651 |INF| 1636|2023-04-25 19:31:04.799011| MAIN > Waiting for stable gopt (relative threshold is 30%)

19:32:43.493720| MAIN > RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR

639|2023-04-25 19:33:10.028898| MAIN > Waiting for stable gopt (relative threshold is 30%)
WfsArbitrator_1651 |INF| 1640|2023-04-25 19:33:43.808321| MAIN > Gopt is stable, renormalizing gains
WfsArbitrator_1651 |INF| 1641|2023-04-25 19:33:43.808633| MAIN > Waiting again for a few iterations
WfsArbitrator_1651 |INF| 1642|2023-04-25 19:34:09.552237| MAIN > Closing gopt tracking loop
WfsArbitrator_1651 |DEB| 1643|2023-04-25 19:34:09.552932| MAIN > arbFunc startGoptInternal done.

reduce flux from 16.8 to 17.0

TN:_193502,_

MAIN > Waiting for stable gopt (relative threshold is 30%)
WfsArbitrator_1650 |WAR| 451|2023-04-25 19:00:53.671758| MAIN > OCAM Bad Frames/Slopes Warning, code 128
WfsArbitrator_1650 |WAR| 452|2023-04-25 19:00:53.671801| MAIN > OCAM Warning Description: Code 128 - Noisy Octants: Pixel RMS in external octants is high
WfsArbitrator_1650 |WAR| 453|2023-04-25 19:00:53.671814| MAIN > OCAM Suggested action to recover: No action required; no impact on performance is expected
20232504 19:00:53.6721 Warning: Warning state caused by Bad Frames or Slopes, CODE:128 - No Action required
WfsArbitrator_1651 |INF| 1340|2023-04-25 19:01:08.383425| MAIN > Gopt is stable, renormalizing gains
WfsArbitrator_1651 |INF| 1341|2023-04-25 19:01:08.384044| MAIN > Waiting again for a few iterations
WfsArbitrator_1651 |INF| 1342|2023-04-25 19:01:26.863819| MAIN > Closing gopt tracking loop

12:39pm

stop.

ocam safe

luci filters; blind/blind

2:16PM

resume

IFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Apr 25 21:15:50.694 2023 aos.info - WFS source set to: FLAOWFS
Tue Apr 25 21:15:50.740 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1700.00_sd3892.fits

optimize:_214425

TN+luci:_214615,_214821,_3sec_10iter:_214937,_215022,_215106

dark.luci2.20230426.0018,0019.fits

resume: _215323,_215413

03:00PM

stop

IDL log

dl_ctrl_112989 |INF| 11233|2023-04-25 16:41:58.147771| MAIN > min/max/mean of the filt_dcomm: 1.46301E-05 4.94243E-05 2.52991E-05
idl_ctrl_112989 |INF| 11234|2023-04-25 16:41:58.148017| MAIN > Piston requested to be applied is too apply too big returning
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > % At LOG_MESSAGE 10 /home/aoeng/live/aoroot/idl/adsec_lib/adsec_utilitie
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . s/log_message.pro
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . % FSM_LOAD_SHAPE 286 /home/aoeng/live/aoroot/idl/adsec_lib/adsec_scripts/
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . fsm_load_shape.pro
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . % FSM_SKIP_RECOVERY 175 /home/aoeng/live/aoroot/idl/adsec_lib/adsec_scripts
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . /fsm_skip_recovery.pro
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . % FSM_STOP_AO 10 /home/aoeng/live/aoroot/idl/adsec_lib/adsec_scripts/
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . fsm_stop_ao.pro
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > . % $MAIN$
idl_ctrl_112989 |INF| 11235|2023-04-25 16:41:58.148083| MAIN > .
idl_ctrl_112989 |INF| 11236|2023-04-25 16:41:58.172726| MAIN > IDL Safe params (current absolute or rms or delta, position absolute o delta o rms) out of bounds
idl_ctrl_112989 |INF| 11237|2023-04-25 16:41:58.172897| MAIN > FSM_LOAD_SHAPE: -----------> Piston requested to be applied is too apply
idl_ctrl_112989 |INF| 11237|2023-04-25 16:41:58.172897| MAIN > . too big returning -10046
idl_ctrl_112989 |INF| 11238|2023-04-25 16:41:58.173032| MAIN > -10046
idl_ctrl_112989 |INF| 11239|2023-04-25 16:41:58.173080| MAIN > EndCmd
idl_ctrl_112989 |INF| 11240|2023-04-25 16:42:37.203943| MAIN > Executing command: print,test_demo_mode()
idl_ctrl_112989 |INF| 11241|2023-04-25 16:42:37.204072| MAIN > StartCmd
idl_ctrl_112989 |INF| 11242|2023-04-25 16:42:37.204100| MAIN > IDL license file is running.
idl_ctrl_112989 |INF| 11243|2023-04-25 16:42:37.204114| MAIN > 0

.....

housekeeper.R.202304250000.log:housekeeper_113068 |ERR| 119683|2023-04-25 16:41:55.849702| FUNCTEMERGENCYSTOP > BCUCURRENTVSSP-0001 = -17.7769 [Funct.cpp:95]
housekeeper.R.202304250000.log:housekeeper_113068 |INF| 119684|2023-04-25 16:41:55.849736| ADAM-MODBUS > AdamModbus: disabling coils...
housekeeper.R.202304250000.log:housekeeper_113068 |INF| 119685|2023-04-25 16:41:55.866854| FUNCTEMERGENCYSTOP > [FunctEmergencyStop] try to send Alert to AdSec Arbitrator [Funct.cpp:124]
housekeeper.R.202304250000.log:housekeeper_113068 |INF| 119686|2023-04-25 16:41:55.899462| FUNCTEMERGENCYSTOP > [FunctEmergencyStop] Alert to AdSec Arbitrator succesfully s

-- JuanCarlosGuerra - 25 Apr 2023
Topic revision: r2 - 25 Apr 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.