Staff:

LBTO: Juan Carlos

Observer: Shark-Nir team (remote Italy)

Summary.

Remote work with SHARK-NIR team. Main task test the coronograph more sentive.

Telescope had a power bump yesterday.

Details.

08:00am

WFS power on

There is a problem with the shutter door that it requires to have access to the dome. The dome is setup with the low lights on.

it is observed vibrations, so for the Test of the coro requires a quite telescope.

In meantime Shark-Nir s performing alignment and some process tests.

domelights_20230419.png

12:00

Done with the shutter doors.

Lights off.

01:44 PM

Loop open.

AdSecArbitrator_103627|WAR| 781|2023-04-19 20:18:44.529267| MAIN > Skip frame detected! (22.94% of frames skipped.)
AdSecArbitrator_103627|WAR| 782|2023-04-19 20:18:45.589197| MAIN > Skip frame detected! (108.29% of frames skipped.)
AdSecArbitrator_103627|WAR| 783|2023-04-19 20:18:45.589312| MAIN > Maximum skip frames reached: 108.29% of frames skipped. Will alert ICE clients.
AdSecArbitrator_103627|WAR| 784|2023-04-19 20:18:46.621136| MAIN > Skip frame detected! (108.65% of frames skipped.)
AdSecArbitrator_103627|WAR| 785|2023-04-19 20:18:46.621243| MAIN > Maximum skip frames reached: 108.65% of frames skipped. Will alert ICE clients.
AdSecArbitrator_103627|INF| 786|2023-04-19 20:18:46.626619| MAIN > Received cmd: StopAo(1)
  • negative counts in the ocam.
MAG:

BFiller_31816 |INF| 628804|2023-04-19 20:18:41.266807| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),11.3862)
DBFiller_31816 |INF| 628854|2023-04-19 20:18:43.720351| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),11.3862)
DBFiller_31816 |INF| 628925|2023-04-19 20:18:45.764051| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),12.0491)
DBFiller_31816 |INF| 628982|2023-04-19 20:18:47.812595| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),12.0491)
DBFiller_31816 |INF| 629050|2023-04-19 20:18:49.833800| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),14.0273)
DBFiller_31816 |INF| 629136|2023-04-19 20:18:51.742721| MAIN > insert into auxloops_L_modalplotTask_MAG (date_t,time_t,auxloops_L_modalplotTask_MAG1) values (CURRENT_DATE(),CURRENT_TIME(),14.0273)

COUNTS:

DBFiller_31816 |INF| 628780|2023-04-19 20:18:40.662339| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15574)
DBFiller_31816 |INF| 628842|2023-04-19 20:18:42.718553| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15574)
DBFiller_31816 |INF| 628899|2023-04-19 20:18:44.729708| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),15049)
DBFiller_31816 |INF| 628973|2023-04-19 20:18:46.811181| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),-1.31266e+06)
DBFiller_31816 |INF| 629038|2023-04-19 20:18:48.831405| MAIN > insert into optloopdiag_L_COUNTS (date_t,time_t,optloopdiag_L_COUNTS1) values (CURRENT_DATE(),CURRENT_TIME(),-1.3237e+06)

OCAM VIEW:

CDVIEWocam200.202304190000.log:python_32401 |INF| 181789|2023-04-19 20:18:43.248394| MAIN > Total counts/subap: 86.173800 - framerate: 1700.0 - Flux: 7398
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181790|2023-04-19 20:18:43.568792| MAIN > Total counts/subap: 86.198400 - framerate: 1700.0 - Flux: 7400
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181791|2023-04-19 20:18:43.573765| MAIN > Total counts/subap: 66.444600 - framerate: 1700.0 - Flux: 5704
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181792|2023-04-19 20:18:43.626204| MAIN > Total counts/subap: 46.703100 - framerate: 1700.0 - Flux: 4009
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181793|2023-04-19 20:18:43.713380| MAIN > Total counts/subap: 27.047700 - framerate: 1700.0 - Flux: 2322
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181794|2023-04-19 20:18:43.730861| MAIN > Total counts/subap: 7.552200 - framerate: 1700.0 - Flux: 648
CCDVIEWocam200.202304190000.log:python_32401 |INF| 181795|2023-04-19 20:18:43.776288| MAIN > Total counts/subap: 0.000000 - framerate: 1700.0 - Flux: 0

  • open loop and change bin and reclose.
2:37PM

SET SAFE

WRAP UP.

-- JuanCarlosGuerra - 19 Apr 2023
Topic revision: r3 - 19 Apr 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.