08:20

Telescope release for testing.

08:30

Power on WFS

ocam OK

bcu47 temperature -2C
  • waiting warming up .
  • 09:10 temp >7
FLAT.

16:30:33.541622| MAIN > Maximum mode index used to apply flat -> # 639

TEST PRESET.

Mon Mar 13 16:28:30.546 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[902] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Mar 13 16:28:30.789 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits

OPTIMIZE

GOPT

TN+luci:20230313_164513,_164658

auxloop error/war.

python_121885 |DEB| 2994|2023-03-13 16:29:08.004021| MAIN > Traceback (most recent call last):
python_121885 |DEB| 2995|2023-03-13 16:29:08.004035| MAIN > File "/home/AOeng/live/aoroot/lib/python/auxloops/auxProducer.py", line 60, in step
python_121885 |DEB| 2996|2023-03-13 16:29:08.004059| MAIN > self.read()
python_121885 |DEB| 2997|2023-03-13 16:29:08.004073| MAIN > File "/home/AOeng/live/aoroot/lib/python/auxloops/auxProducer.py", line 43, in read
python_121885 |DEB| 2998|2023-03-13 16:29:08.004086| MAIN > self.shmRecord = self.adapter.readTelemetry( self.flaoBufName, timeout=1.0, simulateSpeed=True)
python_121885 |DEB| 2999|2023-03-13 16:29:08.004104| MAIN > File "/usr/lib/python2.6/site-packages/oaalib/msgdAdapter.py", line 148, in readTelemetry
python_121885 |DEB| 3000|2023-03-13 16:29:08.004117| MAIN > return self.aoapp.BufRead( streamName, timeout=timeout*1000)['data']
python_121885 |DEB| 3001|2023-03-13 16:29:08.004130| MAIN > File "/home/AOeng/live/aoroot/lib/python/AdOpt/thAOApp.py", line 747, in BufRead
python_121885 |DEB| 3002|2023-03-13 16:29:08.004143| MAIN > raise AdOptError ( code=data['errcode'], errstr='Reading shared buffer '+bufname)
python_121885 |DEB| 3003|2023-03-13 16:29:08.004155| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR

3003|2023-03-13 16:29:08.004155| MAIN > AdOptError: Reading shared buffer masterdiagnostic.L:OPTLOOPBUF - TIMEOUT_ERROR
python_121885 |DEB| 70|2023-03-13 16:43:08.322364| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322365| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322363| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322395| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322424| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322404| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322397| MAIN > SIGINT received... cleaning-up application...
python_121885 |DEB| 70|2023-03-13 16:43:08.322410| MAIN > SIGINT received... cleaning-up application...

09:46

Check for DMS is getting the WFS telemetry; camera lens pos and error, also the rot angle.

ok

bin1 rotation

chamber temp:-0.5

09:56 backward

Ok

froward

ok

10:15

bin2 rotation.

shutter 70

mag:11

backward/forward.

cancel preset ttofload not active

recover

it triggers an overillumination. (?)

recover

shutter 60

mag 12.4

10:40 start

ok

11:00

Bin3 rotation.

shutter 55

mag 14.3

ok

made a pupil shift of x=-1.

>>> makePupils.movePupils('20220901_070135',1,0,240,4)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230313_181708/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230313_181708/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 148
out_of_pupil_slopes 2552
lines_to_add 11
residual_pixels_to_add 38
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230313_181708
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20230313_181708"
'20230313_181708

test close loop, the pupils are not flat when applying gains.

TN:_182846

11:42

bin4 rotation

ok.

PSF check

Bin1

dist s1.6@1700Hz.

TN:_192017

fringes at the edge of the pupil.

second optimize.

skip frames.

rotator 341.

rerot pos 180

rerot trak off

move the rerotator 10 degrees

rerot trak on

rertoa pos 180.1

less fringing.

TN:_192959

moving the rerotator and reaches 178 with a better reduction of the HO2 oscillation, not fringing.

optimize gain:much better. 209230313_193556

TN:_193459

gopt:

TN:_194019

stop tracking

gain zero

home rerot.

track on

gain low.

optimize: _194533

not fringins.

rerot:180.1

gopt

TN:_194751,_194941,_195113.

12:54

handover to Doug

-- Main.Ju

anCarlosGuerra - 13 Mar 2023
Topic revision: r1 - 13 Mar 2023, JuanCarlosGuerra