Staff:

LBTO: Juan Carlos,Greg, David

Observer: SHARK-NIR (LBTO control room), Forerunner (remote)

forecast.

forecast0_20230308.png

forecast1_20230308.png

Details.

Power bump during the morning of today.

Checking the PDU showed many outlet off.

pdu_sx_20230308_before.png

5:30
  • pwer on
  • ocam
  • ok
6:23
  • Ocam not live.
  • saved a dump
BCUread_28631.202303090000.log dumpBCU2KDSP_20230309_012449.txt ocam2.L.202303090000.log
BCUread_28764.202303090000.log dumpBCU2KDSPext_20230309_012449.txt ocam2.L_TELEMETRY.202303090000.tel
BCUread_28881.202303090000.log dumpBCU2KSDRAM_20230309_012449.txt
BCUread_29012.202303090000.log dumpBCU2KSRAM_20230309_012449.txt

  • change bin from HW gui
  • masterdiagnostic process down/
  • start goes down again.
  • not recorable.
  • telescope at 30 degrees for opening.
adsec masterdiagnotic log:

_67588|INF| 234|2023-03-09 01:36:05.729797| MAIN > OFramesHistory::dumpToFile: output file /local/aolog/2023/03/09/ADAPTIVE-SECONDARY_00001678325765_20230309_013605.bin
MasterDiagnostic_67588|INF| 235|2023-03-09 01:36:05.730056| MAIN > Dumping 1st part of size 745732...
MasterDiagnostic_67588|INF| 236|2023-03-09 01:36:05.730730| MAIN > Dumping 2nd part of size 56618268...
MasterDiagnostic_67588|INF| 237|2023-03-09 01:36:05.781718| ALERT-NOTIFIER > ArbitratorInterface to adsecarb.L succesfully created!
MasterDiagnostic_67588|INF| 238|2023-03-09 01:36:05.781895| MAIN > Alert for dump to adsec arbitrator successfully sent
MasterDiagnostic_67588|ERR| 239|2023-03-09 01:36:05.781993|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_67588|ERR| 239|2023-03-09 01:36:05.781993|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 240|2023-03-09 01:36:05.782062|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 41c0 32870f
MasterDiagnostic_67588|ERR| 240|2023-03-09 01:36:05.782062|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 241|2023-03-09 01:36:05.782112|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_67588|WAR| 242|2023-03-09 01:36:05.782143|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_67588|ERR| 243|2023-03-09 01:36:05.782250|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_67588|ERR| 243|2023-03-09 01:36:05.782250|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 244|2023-03-09 01:36:05.782285|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 41c0 328710
MasterDiagnostic_67588|ERR| 244|2023-03-09 01:36:05.782285|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 245|2023-03-09 01:36:05.782341|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_67588|WAR| 246|2023-03-09 01:36:05.782361|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_67588|ERR| 247|2023-03-09 01:36:05.782448|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_67588|ERR| 247|2023-03-09 01:36:05.782448|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 248|2023-03-09 01:36:05.782484|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 41c0 328711
MasterDiagnostic_67588|ERR| 248|2023-03-09 01:36:05.782484|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 249|2023-03-09 01:36:05.782515|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_67588|WAR| 250|2023-03-09 01:36:05.782538|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_67588|ERR| 251|2023-03-09 01:36:05.782573|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_67588|ERR| 251|2023-03-09 01:36:05.782573|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 252|2023-03-09 01:36:05.782602|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 41c0 328712
MasterDiagnostic_67588|ERR| 252|2023-03-09 01:36:05.782602|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 253|2023-03-09 01:36:05.782623|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_67588|WAR| 254|2023-03-09 01:36:05.782645|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_67588|ERR| 255|2023-03-09 01:36:05.782696|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_67588|ERR| 255|2023-03-09 01:36:05.782696|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 256|2023-03-09 01:36:05.782739|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 41c0 328713
MasterDiagnostic_67588|ERR| 256|2023-03-09 01:36:05.782739|ADAPTIVE-SECONDARY > .
MasterDiagnostic_67588|ERR| 257|2023-03-09 01:36:05.782774|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_67588|WAR| 258|2023-03-09 01:36:05.782795|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_67588|WAR| 259|2023-03-09 01:36:05.783053| BCUSWITCH > FramesDownloader BCUSWITCH: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 806 (instead of packetId 2 for frameId 790)

  • power cycle #16
  • set bin from ocam hw gui
  • ok.
  • live
  • set bin CCD47 from HW Gui
  • ok
  • masterdiagnostic ok
  • telescope at 90
  • grep in the log for the events to start wfs masterdiagnotic process: ------------------- STARTING MASTER DIAGNOSTIC SYSTEM --------------------

6:46
  • Open.
  • wind restrictions.
06:54
  • test preset.
  • seeing: 1.5
  • David recomendation ot select different target NE
7:13

AO preset.

Thu Mar 9 02:13:06.043 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[186] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:0.00554964[0.00554964],roy:0.0417102,mag:6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 9 02:13:06.055 2023 aos.info - WFS source set to: LBTIWFS

loop closed.

center pupil ocam not live

saved dump.

07:22
  • adsc_stop/start
  • fastdiagnostic not up after the start
  • wfs stop/start
  • masterdiagnotic process down/start.
  • Ocam live.
  • Preset AO
  • OK
  • ccd47 went not live.
  • ocam went not live.
  • Ocam set safe, ambient.
  • Power cycle #5,8,15,16
  • w-stop/start_all
  • ocam ,ccd47
  • live.
7:38 presetAO

Thu Mar 9 02:13:06.043 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[186] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:0.00554964[0.00554964],roy:0.0417102,mag:6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Mar 9 02:13:06.055 2023 aos.info - WFS source set to: LBTIWFS
  • OK.
  • centering in shark-nir
  • field rotation run for almost one hour.
  • optimized.
  • gopt.
  • TN:20230309_030238,_030313,_030329,_030421
  • offset x 0.1 x->66.547
  • TN:_030558,_030654,_030713
  • TN:_031148,_031215,_021330
08:16
  • loop open
  • moved horizontal back and forward. x=119 to 30 approx
  • AdSecArbitrator _118570|WAR| 302|2023-03-09 03:15:39.218775| MAIN > Skip frame detected! (63.59% of frames skipped.)
    AdSecArbitrator_118570|WAR| 303|2023-03-09 03:15:40.267265| MAIN > Skip frame detected! (108.24% of frames skipped.)
  • 03:15:41.274304| MAIN > Loop fault detected. Opening loop.
    03:15:44.733184| MAIN > ... 2 equal lines suppressed
    03:15:44.733222| MAIN > Alert from AdSec [177] - SkipFrame
  • reclosed
  • optimized
  • gopt
  • TN:_031951,_032008,_032037,_032056,_032109,_032319,_032933
  • TN:_033129,_033156,_033219
  • TN:_033408,_033438,_
08:35
  • seeing variable 1.5 to 1.2
  • TN:_033523,_033559,_033622
  • TN:_034056,_034119,_034141,_034202,_034230
  • TN:_034525,_034602,_034735,_034915
ovsm

ovms_20230308_0846.png
  • loop open \same chopping effect.
03:49:46.396640| MAIN > Skip frame detected! (2.47% of frames skipped.)
03:49:47.403841| MAIN > Skip frame detected! (56.47% of frames skipped.)
03:49:48.413616| MAIN > Skip frame detected! (108.35% of frames skipped.)
03:49:48.413733| MAIN > Maximum skip frames reached: 108.35% of frames skipped. Will alert ICE clients.
03:49:49.423066| MAIN > Skip frame detected! (113.71% of frames skipped.)
03:49:49.423174| MAIN > Maximum skip frames reached: 113.71% of frames skipped. Will alert ICE clients.
03:49:49.428267| MAIN > Received cmd: StopAo(1)
  • reclosed from flao gui
  • optimize
  • gopt
  • TN:_034915,_035710,_035740
  • seeing blow up
9 03:58:18.956986| MAIN > Skip frame detected! (6.71% of frames skipped.)
AdSecArbitrator_118570|WAR| 634|2023-03-09 03:58:20.748273| MAIN > Skip frame detected! (77.12% of frames skipped.)
AdSecArbitrator_118570|WAR| 635|2023-03-09 03:58:21.825721| MAIN > Skip frame detected! (87.06% of frames skipped.)
AdSecArbitrator_118570|WAR| 636|2023-03-09 03:58:22.844562| MAIN > Skip frame detected! (110.12% of frames skipped.)
AdSecArbitrator_118570|WAR| 637|2023-03-09 03:58:22.844710| MAIN > Maximum skip frames reached: 110.12% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 638|2023-03-09 03:58:23.895999| MAIN > Skip frame detected! (107.65% of frames skipped.)
AdSecArbitrator_118570|WAR| 639|2023-03-09 03:58:23.896111| MAIN > Maximum skip frames reached: 107.65% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 640|2023-03-09 03:58:23.901141| MAIN > Received cmd: StopAo (1)
  • loop open
  • 2arcsec.
  • optimize
  • gopt
  • TN:_040147,_040204,_040225
  • TN:_040438,_
09:05
  • seeing goes up
  • _040525,
  • seeing blowup.
AdSecArbitrator _118570|WAR| 928|2023-03-09 04:07:19.335731| MAIN > Skip frame detected! (17.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 929|2023-03-09 04:07:20.348126| MAIN > Skip frame detected! (18.18% of frames skipped.)
AdSecArbitrator_118570|WAR| 930|2023-03-09 04:07:21.483151| MAIN > Skip frame detected! (22.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 931|2023-03-09 04:07:22.520829| MAIN > Skip frame detected! (21.41% of frames skipped.)
AdSecArbitrator_118570|WAR| 932|2023-03-09 04:07:23.574232| MAIN > Skip frame detected! (47.94% of frames skipped.)
AdSecArbitrator_118570|WAR| 933|2023-03-09 04:07:24.652756| MAIN > Skip frame detected! (109.82% of frames skipped.)
AdSecArbitrator_118570|WAR| 934|2023-03-09 04:07:24.652950| MAIN > Maximum skip frames reached: 109.82% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 935|2023-03-09 04:07:25.659094| MAIN > Skip frame detected! (89.71% of frames skipped.)
AdSecArbitrator_118570|WAR| 936|2023-03-09 04:07:26.666786| MAIN > Skip frame detected! (103.88% of frames skipped.)
AdSecArbitrator_118570|WAR| 937|2023-03-09 04:07:26.666908| MAIN > Maximum skip frames reached: 103.88% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 938|2023-03-09 04:07:27.804254| MAIN > Skip frame detected! (106.00% of frames skipped.)
AdSecArbitrator_118570|WAR| 939|2023-03-09 04:07:27.804349| MAIN > Maximum skip frames reached: 106.00%
  • loop open
  • loop closed
  • optimize
  • gopt
  • TN:041113,_041142,_041158,_041247
09:13
  • high variable seeing, the PSF in the ccd47 blows
  • TN:_041408,_041426,_041452
  • seeing variable 1.6-1.2
  • TN:_041752,_041821,_variability_seeing_20230308_0919.png

09:22
  • PresetAO
  • optimize
  • gopt
  • TN:_042808,_042938,_043006
  • skipping frames,
  • dimm not available
  • seeing jumping.
  • skipping frames up to 70%
  • reduce ho2 two clicks
  • more stable
  • seeing getting stable
  • back ho2 two clicks
  • TN:_043548,_043629,_
  • seeing jumping...
  • skipping frames up to 50%
  • TN:_043228,_043410
  • loop open skipping frames.
AdSecArbitrator _118570|WAR| 1644|2023-03-09 04:39:03.802087| MAIN > Skip frame detected! (79.35% of frames skipped.)
AdSecArbitrator_118570|WAR| 1645|2023-03-09 04:39:04.873535| MAIN > Skip frame detected! (116.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 1646|2023-03-09 04:39:04.873723| MAIN > Maximum skip frames reached: 116.76% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 1647|2023-03-09 04:39:04.966203| MAIN > Received cmd: StopAo (1)
  • optimize
  • failed first, good second
  • gopt.
  • TN:_044151,_044221,_044326
  • skipping frames, seeing variable, gopt oscillating, modalSr from 80 to 60
  • loop open
AdSecArbitrator _118570|WAR| 1799|2023-03-09 04:47:41.593924| MAIN > Skip frame detected! (96.29% of frames skipped.)
AdSecArbitrator_118570|WAR| 1800|2023-03-09 04:47:42.599724| MAIN > Skip frame detected! (108.18% of frames skipped.)
AdSecArbitrator_118570|WAR| 1801|2023-03-09 04:47:42.599879| MAIN > Maximum skip frames reached: 108.18% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 1802|2023-03-09 04:47:43.679256| MAIN > Skip frame detected! (108.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 1803|2023-03-09 04:47:43.679449| MAIN > Maximum skip frames reached: 108.53% of fra
  • optimize
  • gopt
09 04:50:16.099734| MAIN > RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR
WfsArbitrator_27414|DEB| 965|2023-03-09 04:50:36.094269| MAIN > arbFunc startGoptInternal (, 'LBTIWFS', 'SHARK')
WfsArbitrator_27414|INF| 966|2023-03-09 04:50:36.094552| MAIN > Waiting for stable gopt (relative threshold is 15%)
WfsArbitrator_27414|ERR| 967|2023-03-09 04:51:18.387874| MAIN > RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR
WfsArbitrator_27414|DEB| 968|2023-03-09 04:52:09.792915| MAIN > arbFunc startGoptInternal (, 'LBTIWFS', 'SHARK')
WfsArbitrator_27414|INF| 969|2023-03-09 04:52:09.793222| MAIN > Waiting for stable gopt (relative threshold is 15%)
WfsArbitrator_27414|ERR| 970|2023-03-09 04:52:53.245926| MAIN > RETRY: Gopt did not stabilize within 10 iterations (-5001) TIMEOUT_ERROR
  • gopt probe signal low.
  • try two more times.
  • TN:_045543,_045635,_045658

09:58

Apply Fourier mode.

  • command: python run-ncpa.py --modes 118 --coefficients 0e-9 --kl=KL_v20
5nm
  • TN:_045846,_045918
0
  • TN:_050142
10
  • TN:_050445,_050552
  • The mode is applied, but it is reseated even when the ncpa tracking is turned off.
The modal plot shows once.

modalplot_applied_peak.png

10:29
  • Xianyu debugging
  • TN:_052904,_053010,_053023
  • dimm measuring.
  • seeing 1.2"
  • PSF more stable in the CCD47, gopt stable
  • TN:_053105,_053125,_053159
10:32
  • loop open due to skip frames.
  • TN:_053433,_053452,_
10:45
  • Doug connected.
  • looking into the application or not of the mode.
  • it seems that it is reseated.
apply 10nm to 119

TN:_060435
  • loop open
  • skip frames
dSecArbitrator_118570|INF| 2515|2023-03-09 06:05:57.891877| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_118570|INF| 2516|2023-03-09 06:05:57.989501| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|WAR| 2517|2023-03-09 06:06:12.963458| MAIN > Skip frame detected! (0.24% of frames skipped.)
AdSecArbitrator_118570|WAR| 2518|2023-03-09 06:06:19.161976| MAIN > Skip frame detected! (60.12% of frames skipped.)
AdSecArbitrator_118570|WAR| 2519|2023-03-09 06:06:20.167427| MAIN > Skip frame detected! (108.18% of frames skipped.)
AdSecArbitrator_118570|WAR| 2520|2023-03-09 06:06:20.167594| MAIN > Maximum skip frames reached: 108.18% of frames skipped. Will alert ICE clients.
idl_118385 |INF| 1181|2023-03-09 06:06:21.184928| MAIN > fsm_stop_ao start
  • reclosed
  • optimize
  • gopton
20nm on
  • TN:_060926,_060956,_061015
11:11
  • seeing 1"
  • TN:_061410,_061604,_061659,_061719
  • seeing variable 0.9 to 1.3
  • Tn:_062253,_062325,_062959
  • measuring transition from 20 to 0
  • TN_063228
0 to 20
  • TN:_063715
11:40 loop open

skip frames.

AdSecArbitrator _118570|INF| 2607|2023-03-09 06:37:16.059732| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|WAR| 2608|2023-03-09 06:40:28.416520| MAIN > Skip frame detected! (199.47% of frames skipped.)
AdSecArbitrator_118570|WAR| 2609|2023-03-09 06:40:28.417592| MAIN > Maximum skip frames reached: 199.47% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 2610|2023-03-09 06:40:30.435743| MAIN > Skip frame detected! (107.65% of frames skipped.)
AdSecArbitrator_118570|WAR| 2611|2023-03-09 06:40:30.435916| MAIN > Maximum skip frames reached: 107.65% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 2612|2023-03-09 06:40:31.769866| MAIN > Skip frame detected! (215.06% of frames skipped.)
AdSecArbitrator_118570|WAR| 2613|2023-03-09 06:40:31.770072| MAIN > Maximum skip frames reached: 215.06% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 2614|2023-03-09 06:40:31.775498| MAIN > Received cmd: StopAo (1)
  • reclosed
  • optimize
  • gopt
20nm
  • TN:_064406,_064557,_
  • seeing 2
0nm
  • TN:_064714,_064743,_
sky-variability_20230309_1148.png

20nm

TN:_064933,_064949

Screen Shot 2023-03-08 at 11.50.25 PM.png

0nm

TN:_065225,_065253,_065320

sky-variability_20230309_1153.png

20nm

TN:_065425,_065445,_065500

0nm

_065609,_065631,_065655

seeing improved.

sky-variability_20230309_1157.png

12:00

seeing variable up to 1.5

sky-variability_20230309_1200.png

12:04

15nm

TN:_070414,_070450,_

0nm
  • python run-ncpa.py --modes 118 --coefficients 0e-9 --kl=KL_v20
  • TN:_070548,_070635
15nm
  • TN:_070719,_070735,_
0nm
  • TN:_070845,_070910,_070932
  • Tn:_071327,_
  • loop open
  • skip frames,
  • th psf in the ccd47 moved diagonal about 3 arcsec.
AdSecArbitrator _118570|WAR| 2702|2023-03-09 07:14:34.785575| MAIN > Skip frame detected! (4.41% of frames skipped.)
AdSecArbitrator_118570|WAR| 2703|2023-03-09 07:14:35.896030| MAIN > Skip frame detected! (106.88% of frames skipped.)
AdSecArbitrator_118570|WAR| 2704|2023-03-09 07:14:35.896211| MAIN > Maximum skip frames reached: 106.88% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 2705|2023-03-09 07:14:36.902461| MAIN > Skip frame detected! (106.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 2706|2023-03-09 07:14:36.902630| MAIN > Maximum skip frames reached: 106.53% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 2707|2023-03-09 07:14:36.907900| MAIN > Received cmd: StopAo (1)
AdSecArbitrator_118570|INF| 2708|2023-03-09 07:14:36.908015| COMMANDHANDLER > FSM (status: AORunning) has received

20nm
  • TN:_071828
0nm
  • TN:_072012,_072125,_072149
  • 12:26
  • skip frames.
  • seeing blows
skip_frames_20230309_1227.png
  • TN:_072149
12:30
  • Fourier dismissed.
12:32
  • optimize loop
  • skipping frames up to 15% and gopt not stabilize
  • EL 59

Test ADC

  • dimm not available
  • TN,_073530,_073609,_073653
12:41
  • PSF in CCD47 blown
  • loop open
07:41:02.598400| MAIN > Skip frame detected! (99.12% of frames skipped.)
AdSecArbitrator_118570|WAR| 3194|2023-03-09 07:41:02.598516| MAIN > Maximum skip frames reached: 99.12% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3195|2023-03-09 07:41:04.751172| MAIN > Skip frame detected! (118.47% of frames skipped.)
AdSecArbitrator_118570|WAR| 3196|2023-03-09 07:41:04.751296| MAIN > Maximum skip frames reached: 118.47% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3197|2023-03-09 07:41:05.806802| MAIN > Skip frame detected! (108.29% of frames skipped.)
AdSecArbitrator_118570|WAR| 3198|2023-03-09 07:41:05.806927| MAIN > Maximum skip frames reached: 108.29

negative counts.

saved dump (two sets)

-rw-rw-r--. 1 sxwunit sxwunit 19344863 Mar 9 07:41 dumpBCU2KDSP_20230309_074145.txt
-rw-rw-r--. 1 sxwunit sxwunit 48531439 Mar 9 07:41 dumpBCU2KDSPext_20230309_074145.txt
-rw-rw-r--. 1 sxwunit sxwunit 19113879 Mar 9 07:41 dumpBCU2KSRAM_20230309_074145.txt
-rw-rw-r--. 1 sxwunit sxwunit 16835674 Mar 9 07:41 dumpBCU2KSDRAM_20230309_074145.txt
-rw-rw-r--. 1 sxwunit sxwunit 74 Mar 9 07:42 dumpBCU2KDSP_20230309_074213.txt
-rw-rw-r--. 1 sxwunit sxwunit 78 Mar 9 07:42 dumpBCU2KDSPext_20230309_074213.txt
-rw-rw-r--. 1 sxwunit sxwunit 19113841 Mar 9 07:42 dumpBCU2KSRAM_20230309_074213.txt
-rw-rw-r--. 1 sxwunit sxwunit 16835674 Mar 9 07:42 dumpBCU2KSDRAM_20230309_074213.txt

-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:41 BCUread_30740.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:41 BCUread_30967.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:41 BCUread_31118.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:41 BCUread_31310.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:42 BCUread_698.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:42 BCUread_710.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:42 BCUread_723.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 07:42 BCUread_917.202303090000.log

  • reconfigure
  • it didn;t work
  • restart wfs masterdiagnotic
  • reconfigure ocam from hw gui.
  • OK
  • optimize
  • gopt.
  • TN:_075310,_075328,_075347
12:56
  • seeing 2"
  • TN:_075631,_075650
1:09
  • ;loop opne
  • ocam negative counts
  • saved dump
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 08:09 BCUread_13672.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 08:09 BCUread_13908.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 08:09 BCUread_14054.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 08:09 BCUread_14301.202303090000.log

-rw-rw-r--. 1 sxwunit sxwunit 19354157 Mar 9 08:09 dumpBCU2KDSP_20230309_080930.txt
-rw-rw-r--. 1 sxwunit sxwunit 48411279 Mar 9 08:09 dumpBCU2KDSPext_20230309_080930.txt
-rw-rw-r--. 1 sxwunit sxwunit 19103879 Mar 9 08:09 dumpBCU2KSRAM_20230309_080930.txt
-rw-rw-r--. 1 sxwunit sxwunit 16893649 Mar 9 08:09 dumpBCU2KSDRAM_20230309_080930.txt
  • reconfigure ocam
  • not luck
  • optimcal buffer
  • power cycle bcu2k
  • restart masterdiagnotic process.
  • reconfigure ocam
  • OK
  • TN:_081852,_081918,_081932
  • TN:_082128
1:23
  • el 46
  • loop open skip frames.
  • ator_118570|INF| 3385|2023-03-09 08:21:28.481150| COMMANDHANDLER > Command Save status (code 2024) successfully completed
    AdSecArbitrator_118570|WAR| 3386|2023-03-09 08:22:50.921694| MAIN > Skip frame detected! (22.24% of frames skipped.)
    AdSecArbitrator_118570|WAR| 3387|2023-03-09 08:22:51.930282| MAIN > Skip frame detected! (107.41% of frames skipped.)
    AdSecArbitrator_118570|WAR| 3388|2023-03-09 08:22:51.930444| MAIN > Maximum skip frames reached: 107.41% of frames skipped. Will alert ICE clients.
    AdSecArbitrator_118570|WAR| 3389|2023-03-09 08:22:52.938592| MAIN > Skip frame detected! (108.35% of frames skipped.)
    AdSecArbitrator_118570|WAR| 3390|2023-03-09 08:22:52.938724| MAIN > Maximum skip frames reached: 108.35% of frames skipped. Will alert ICE clients.
    AdSecArbitrator_118570|INF| 3391|2023-03-09 08:22:52.944094| MAIN > Received cmd: StopAo (1)
  • optimize
  • gopt
  • Tn:_082539,_082604
1:32
  • seeing going bad.TN:_083239
  • no dimm available
sky-variability_20230309_0133.png

01:38

sky-variability_20230309_0139.png
  • seeing improved.gopt stable, sr high
  • TN:_083759,_083833

1:41
  • Open loop
  • cancel preset
hu Mar 9 08:43:54.715 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[207] (aomode:ACE-AO,focst:bentGregorianCenter,instr:SHARK,wfs:LBTIWFS,sox:0[0],soy:0,rox:0.0125274[0.0125274],roy:-0.0352762,mag:5.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • optmize
  • gopt
  • TN:085243,_085306,_085346
01:57
  • el 86
  • psf moved away and back
9 08:56:59.505546| MAIN > Skip frame detected! (24.06% of frames skipped.)
AdSecArbitrator_118570|WAR| 3523|2023-03-09 08:57:00.584004| MAIN > Skip frame detected! (107.47% of frames skipped.)
AdSecArbitrator_118570|WAR| 3524|2023-03-09 08:57:00.584181| MAIN > Maximum skip frames reached: 107.47% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3525|2023-03-09 08:57:01.608043| MAIN > Skip frame detected! (108.41% of frames skipped.)
AdSecArbitrator_118570|WAR| 3526|2023-03-09 08:57:01.609041| MAIN > Maximum skip frames reached: 108.41% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 3527|2023-03-09 08:57:01.614136| MAIN > Received cmd: StopAo (1)
  • reclose
  • optimize
  • gopt:
  • Tn:_090103,_090133,_090257
  • shark reports that the psf is astigmatic
  • skipping frames reduce one click ho2 reduced the skip frames.
  • 090618,_090829,_090849
  • observed in the pupils some jumps
el 87

tn:_091046,_091132
  • shark check with internal fiber for PSF.
  • It looks like that the aberration tracking didn;t went well
  • high peak frequencies at 200Hz
vibraion_200Hz.png

  • pupils jumping around. Where is coming the extra vibrations.....?
  • TN_091843,_091946

OVSm plots

ovms_2.18.39.png

ovms_021749.png

ovms_2.17.51.png

  • oscillation at 200Hz.
oscillation-200Hz_0220.png
  • TN:092121,_092804,_092834,_
2:30
  • seeing jumps.
AdSecArbitrator _118570|WAR| 3805|2023-03-09 09:31:12.896213| MAIN > Skip frame detected! (5.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 3806|2023-03-09 09:31:13.902052| MAIN > Skip frame detected! (44.65% of frames skipped.)
AdSecArbitrator_118570|WAR| 3807|2023-03-09 09:31:14.909064| MAIN > Skip frame detected! (118.06% of frames skipped.)
AdSecArbitrator_118570|WAR| 3808|2023-03-09 09:31:14.909224| MAIN > Maximum skip frames reached: 118.06% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3809|2023-03-09 09:31:15.932923| MAIN > Skip frame detected! (106.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 3810|2023-03-09 09:31:15.933106| MAIN > Maximum skip frames reached: 106.76% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 3811|2023-03-09 09:31:15.938297| MAIN > Received cmd: StopAo (1)

2:31 open loop
  • optimize
  • gopt
  • TN:_093415,_093434,_093453
2:41
  • pupil jumping
  • TN:_094109,_094330,_094353
vibrations_20230309_0244.png

02:50
  • dimm 1"
  • Tn:_095008,_095031
  • loop open
  • jump and it return not to the same spot
AdSecArbitrator _118570|INF| 3910|2023-03-09 09:52:01.639887| COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_118570|INF| 3911|2023-03-09 09:52:01.645477| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_118570|WAR| 3912|2023-03-09 09:52:04.681606| MAIN > Skip frame detected! (19.00% of frames skipped.)
AdSecArbitrator_118570|WAR| 3913|2023-03-09 09:52:05.690979| MAIN > Skip frame detected! (33.71% of frames skipped.)
AdSecArbitrator_118570|WAR| 3914|2023-03-09 09:52:06.889739| MAIN > Skip frame detected! (28.59% of frames skipped.)
AdSecArbitrator_118570|WAR| 3915|2023-03-09 09:52:07.896189| MAIN > Skip frame detected! (107.65% of frames skipped.)
AdSecArbitrator_118570|WAR| 3916|2023-03-09 09:52:07.896316| MAIN > Maximum skip frames reached: 107.65% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3917|2023-03-09 09:52:08.902865| MAIN > Skip frame detected! (14.29% of frames skipped.)
AdSecArbitrator_118570|INF| 3918|2023-03-09 09:52:29.512952| MAIN > Received cmd: LoadGainTag ("/local/aomeas/adsec_calib/M2C/KL_v20/gain/gain0.1_10modi.fits", 0)
AdSecArbitrator_118570|INF| 3919|2023-03-09 09:52:29.513033| COMMANDHANDLER > FSM (status: AORunning) has received command 2018 (SetGain)
AdSecArbitrator_118570|INF| 3920|2023-03-09 09:52:29.535303| COMMANDHANDLER > Command SetGain (code 2018) successfully completed
AdSecArbitrator_118570|WAR| 3921|2023-03-09 09:52:30.812002| MAIN > Skip frame detected! (8.24% of frames skipped.)
AdSecArbitrator_118570|WAR| 3922|2023-03-09 09:52:31.817921| MAIN > Skip frame detected! (108.18% of frames skipped.)
AdSecArbitrator_118570|WAR| 3923|2023-03-09 09:52:31.818067| MAIN > Maximum skip frames reached: 108.18% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3924|2023-03-09 09:52:32.873162| MAIN > Skip frame detected! (79.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 3925|2023-03-09 09:52:33.889418| MAIN > Skip frame detected! (34.12% of frames skipped.)
AdSecArbitrator_118570|WAR| 3926|2023-03-09 09:52:34.896212| MAIN > Skip frame detected! (7.88% of frames skipped.)
AdSecArbitrator_118570|WAR| 3927|2023-03-09 09:52:35.902023| MAIN > Skip frame detected! (92.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 3928|2023-03-09 09:52:36.999716| MAIN > Skip frame detected! (108.00% of frames skipped.)
AdSecArbitrator_118570|WAR| 3929|2023-03-09 09:52:36.999904| MAIN > Maximum skip frames reached: 108.00% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3930|2023-03-09 09:52:38.007294| MAIN > Skip frame detected! (108.24% of frames skipped.)
AdSecArbitrator_118570|WAR| 3931|2023-03-09 09:52:38.007480| MAIN > Maximum skip frames reached: 108.24% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 3932|2023-03-09 09:52:38.012401| MAIN > Received cmd: StopAo (1)
  • recentered.
  • recosed.
  • optimize
  • gopt.
  • TN:_095637,_095656,_095714,_095902,_

2:59

negative counts.

loop opens.

AdSecArbitrator _118570|WAR| 3972|2023-03-09 09:56:33.896365| MAIN > Skip frame detected! (2.24% of frames skipped.)
AdSecArbitrator_118570|INF| 3973|2023-03-09 09:56:37.498897| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_118570|INF| 3974|2023-03-09 09:56:37.582640| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|INF| 3975|2023-03-09 09:56:56.181245| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_118570|INF| 3976|2023-03-09 09:56:56.290096| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|INF| 3977|2023-03-09 09:57:14.414563| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_118570|INF| 3978|2023-03-09 09:57:14.498426| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|INF| 3979|2023-03-09 09:59:02.114243| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_118570|INF| 3980|2023-03-09 09:59:02.201966| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|WAR| 3981|2023-03-09 09:59:28.427907| MAIN > Skip frame detected! (66.59% of frames skipped.)
AdSecArbitrator_118570|WAR| 3982|2023-03-09 09:59:29.484696| MAIN > Skip frame detected! (107.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 3983|2023-03-09 09:59:29.484928| MAIN > Maximum skip frames reached: 107.76% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 3984|2023-03-09 09:59:30.522718| MAIN > Skip frame detected! (107.76% of frames skipped.)
AdSecArbitrator_118570|WAR| 3985|2023-03-09 09:59:30.522751| MAIN > Maximum skip frames reached: 107.76% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 3986|2023-03-09 09:59:30.527812| MAIN > Received cmd: StopAo (1)

bcu dumps

-rw-rw-r--. 1 sxwunit sxwunit 19360181 Mar 9 10:00 dumpBCU2KDSP_20230309_100029.txt
-rw-rw-r--. 1 sxwunit sxwunit 48531727 Mar 9 10:00 dumpBCU2KDSPext_20230309_100029.txt
-rw-rw-r--. 1 sxwunit sxwunit 19112826 Mar 9 10:00 dumpBCU2KSRAM_20230309_100029.txt
-rw-rw-r--. 1 sxwunit sxwunit 16835995 Mar 9 10:00 dumpBCU2KSDRAM_20230309_100029.txt

-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 10:00 BCUread_12922.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 10:00 BCUread_13168.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 10:00 BCUread_13285.202303090000.log
-rw-rw-r--. 1 sxwunit sxwunit 0 Mar 9 10:00 BCUread_13556.202303090000.log

  • skip frames.
  • one clock down ho2
  • TN:_101250,_101412
  • dimm 1.5"
  • TN:_101550
3:17
  • center the PSF
  • offset -0.3mm x and Y
  • x=65.973, y=21.17
seeing-20230309_0320.png
  • TN:_102039,_102124,_102232
  • offset y -0.1
  • TN:_102641
03:27

seeing 1.5

seeing_20230309_0327.png

tn:_102857,_
  • 3:30
  • loop closed but not sending commands. (?)
  • force open flao
  • reclosed.
  • optimize
  • gopt
  • tn:_103302,_103423
seeing-20230309334.png

03:40
  • loop open
AdSecArbitrator _118570|WAR| 4201|2023-03-09 10:39:23.869127| MAIN > Skip frame detected! (60.71% of frames skipped.)
AdSecArbitrator_118570|WAR| 4202|2023-03-09 10:39:24.876168| MAIN > Skip frame detected! (117.29% of frames skipped.)
AdSecArbitrator_118570|WAR| 4203|2023-03-09 10:39:24.876306| MAIN > Maximum skip frames reached: 117.29% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 4204|2023-03-09 10:39:25.884190| MAIN > Skip frame detected! (108.35% of frames skipped.)
AdSecArbitrator_118570|WAR| 4205|2023-03-09 10:39:25.884343| MAIN > Maximum skip frames reached: 108.35% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 4206|2023-03-09 10:39:25.889403| MAIN > Received cmd: StopAo (1)
  • reclosed.
  • optimize
  • gopt.
  • TN:_104141,_104201,_104418
seeing-20230309_0344.png

inside wind speed.4.7m/s

Tn:_104622

03:51
  • seeing bubble up to 2" skip frames up to 15, reduce ho2 one click, skip frames reduced, but seeing goes down to 1 restore one click ho2
seeing-0352.png

_105309,_105430

03:57
  • seeing looks stable. ~1 arcsec.
seeing-20230309_0357.png

TN:_105737,_105813

loop open, but status closed: TN_110017 for analysis
  • force open from flao gui
  • reclosed.
  • optimize
  • gopt.
  • TN:_110235,_110257,_110321
  • TN:_110433,_110525,_110601
seeing-20230309_0406.png

04:07

wind speed 6m/s

TN:_110800,_110835,_110904

4:14
  • loop open
  • jump in the seeing, CCD47 blowup
AdSecArbitrator _118570|WAR| 4369|2023-03-09 11:11:52.795995| MAIN > Skip frame detected! (1.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 4370|2023-03-09 11:13:31.597217| MAIN > Skip frame detected! (83.29% of frames skipped.)
AdSecArbitrator_118570|WAR| 4371|2023-03-09 11:13:32.621054| MAIN > Skip frame detected! (107.35% of frames skipped.)
AdSecArbitrator_118570|WAR| 4372|2023-03-09 11:13:32.621180| MAIN > Maximum skip frames reached: 107.35% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 4373|2023-03-09 11:13:33.674566| MAIN > Skip frame detected! (107.24% of frames skipped.)
AdSecArbitrator_118570|WAR| 4374|2023-03-09 11:13:33.674739| MAIN > Maximum skip frames reached: 107.24% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 4375|2023-03-09 11:13:33.679610| MAIN > Received cmd: StopAo (1)
  • reclose
  • optimize
  • gopt
  • TN:_111726,_111746,_111824
4:19

seeing ~1

seeing-20230309_0419.png

  • TN:_112121,_112200,_112221
4:32
  • presetAO
  • ocam not live
  • Tn:_114536,_114737
  • skipping frames up to 40%
  • reduce one click ho2
  • Tn:_114907,_115037
4:51
  • el 85
  • skip frames
  • no seeing avalable
04:53
  • skipping
  • loop open
  • reclose
  • optimize
  • gopt
  • Tn:_115620,_115658,_115730
05:02
  • skipping frames, seeing visible blowup, reduce ho2 one cliock for stability
05:04
  • seeing improved.
  • no dimm available
  • TN:_120449,_120526,_120602
  • TN:_120741,_120823,_120933
  • TN:_121134,_121210,_121258
  • saved dimm images.
  • David note; star in the dimm is about 1 magnitude but it is not doing anything.
  • seeing getting stable.
  • no dimm availbale
  • TN:_121639,_121757,_121827
seeing-20230309_0519.png

TN:_120243,_120343,_

05:22
  • loop open
  • skip frames,
  • reclosed,
  • optimized
  • gopt
  • TN:_122505,_122524,_122543
05:28
  • very stable set
  • TN:_122803,_122945,_123011
seeing-20230309_0528.png

05:34
  • stable seeing ~1"
  • TN:_123447,_123617,_123659,_123724
seeing-20230309_0538.png
  • TN:_124130,_124149,_124234
05:47
  • TN:124719,_124741,
  • TN:_125150,_125213,_125246
seeing-20230309_0553.png

05:54
  • seeing stable
  • TN:_125438,_125525,_125552
  • loop opne
AdSecArbitrator _118570|INF| 5498|2023-03-09 12:55:52.707669| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_118570|WAR| 5499|2023-03-09 12:55:55.361405| MAIN > Skip frame detected! (74.53% of frames skipped.)
AdSecArbitrator_118570|WAR| 5500|2023-03-09 12:55:56.434733| MAIN > Skip frame detected! (107.82% of frames skipped.)
AdSecArbitrator_118570|WAR| 5501|2023-03-09 12:55:56.434924| MAIN > Maximum skip frames reached: 107.82% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|WAR| 5502|2023-03-09 12:55:57.444055| MAIN > Skip frame detected! (108.18% of frames skipped.)
AdSecArbitrator_118570|WAR| 5503|2023-03-09 12:55:57.444168| MAIN > Maximum skip frames reached: 108.18% of frames skipped. Will alert ICE clients.
AdSecArbitrator_118570|INF| 5504|2023-03-09 12:55:57.448871| MAIN > Received cmd: StopAo (1)
  • reclose
  • optimize
  • gopt
  • TN:_125811,_125852,_125936

seeing stable.

seeing-20230309_0602.png

TN:_130306,_130431,_130511,_130657,_130735,_130935,_131037,_131222,_131420

06:14

open loop

cancel preset.

ocam safe.

-- JuanCarlosGuerra - 09 Mar 2023
I Attachment Action Size Date Who Comment
Screen Shot 2023-03-08 at 11.50.25 PM.pngpng Screen Shot 2023-03-08 at 11.50.25 PM.png manage 612 K 09 Mar 2023 - 06:51 JuanCarlosGuerra  
forecast0_20230308.pngpng forecast0_20230308.png manage 736 K 09 Mar 2023 - 00:40 JuanCarlosGuerra  
forecast1_20230308.pngpng forecast1_20230308.png manage 87 K 09 Mar 2023 - 00:40 JuanCarlosGuerra  
modalplot_applied_peak.pngpng modalplot_applied_peak.png manage 170 K 09 Mar 2023 - 13:48 JuanCarlosGuerra  
oscillation-200Hz_0220.pngpng oscillation-200Hz_0220.png manage 1 MB 09 Mar 2023 - 09:20 JuanCarlosGuerra  
ovms_021749.pngpng ovms_021749.png manage 1023 K 09 Mar 2023 - 09:23 JuanCarlosGuerra  
ovms_2.17.51.pngpng ovms_2.17.51.png manage 1013 K 09 Mar 2023 - 09:23 JuanCarlosGuerra  
ovms_2.18.28.pngpng ovms_2.18.28.png manage 1 MB 09 Mar 2023 - 09:23 JuanCarlosGuerra  
ovms_2.18.39.pngpng ovms_2.18.39.png manage 1017 K 09 Mar 2023 - 09:23 JuanCarlosGuerra  
ovms_20230308_0846.pngpng ovms_20230308_0846.png manage 346 K 09 Mar 2023 - 03:47 JuanCarlosGuerra  
pdu_sx_20230308_before.pngpng pdu_sx_20230308_before.png manage 79 K 09 Mar 2023 - 00:40 JuanCarlosGuerra  
seeing-0352.pngpng seeing-0352.png manage 524 K 09 Mar 2023 - 10:54 JuanCarlosGuerra  
seeing-20230309334.pngpng seeing-20230309334.png manage 706 K 09 Mar 2023 - 10:35 JuanCarlosGuerra  
seeing-20230309_0320.pngpng seeing-20230309_0320.png manage 510 K 09 Mar 2023 - 10:22 JuanCarlosGuerra  
seeing-20230309_0344.pngpng seeing-20230309_0344.png manage 470 K 09 Mar 2023 - 10:45 JuanCarlosGuerra  
seeing-20230309_0357.pngpng seeing-20230309_0357.png manage 520 K 09 Mar 2023 - 10:58 JuanCarlosGuerra  
seeing-20230309_0406.pngpng seeing-20230309_0406.png manage 535 K 09 Mar 2023 - 11:07 JuanCarlosGuerra  
seeing-20230309_0419.pngpng seeing-20230309_0419.png manage 413 K 09 Mar 2023 - 11:20 JuanCarlosGuerra  
seeing-20230309_0502.pngpng seeing-20230309_0502.png manage 1 MB 09 Mar 2023 - 12:04 JuanCarlosGuerra  
seeing-20230309_0519.pngpng seeing-20230309_0519.png manage 1 MB 09 Mar 2023 - 12:19 JuanCarlosGuerra  
seeing-20230309_0528.pngpng seeing-20230309_0528.png manage 1 MB 09 Mar 2023 - 12:29 JuanCarlosGuerra  
seeing-20230309_0538.pngpng seeing-20230309_0538.png manage 492 K 09 Mar 2023 - 12:38 JuanCarlosGuerra  
seeing-20230309_0553.pngpng seeing-20230309_0553.png manage 1 MB 09 Mar 2023 - 12:53 JuanCarlosGuerra  
seeing-20230309_0602.pngpng seeing-20230309_0602.png manage 485 K 09 Mar 2023 - 13:04 JuanCarlosGuerra  
seeing_20230309_0327.pngpng seeing_20230309_0327.png manage 526 K 09 Mar 2023 - 10:27 JuanCarlosGuerra  
skip_frames_20230309_1227.pngpng skip_frames_20230309_1227.png manage 1 MB 09 Mar 2023 - 07:27 JuanCarlosGuerra  
sky-variability_20230309_0133.pngpng sky-variability_20230309_0133.png manage 548 K 09 Mar 2023 - 08:34 JuanCarlosGuerra  
sky-variability_20230309_0139.pngpng sky-variability_20230309_0139.png manage 516 K 09 Mar 2023 - 08:39 JuanCarlosGuerra  
sky-variability_20230309_1148.pngpng sky-variability_20230309_1148.png manage 723 K 09 Mar 2023 - 06:49 JuanCarlosGuerra  
sky-variability_20230309_1153.pngpng sky-variability_20230309_1153.png manage 690 K 09 Mar 2023 - 06:55 JuanCarlosGuerra  
sky-variability_20230309_1157.pngpng sky-variability_20230309_1157.png manage 681 K 09 Mar 2023 - 06:58 JuanCarlosGuerra  
sky-variability_20230309_1200.pngpng sky-variability_20230309_1200.png manage 691 K 09 Mar 2023 - 07:01 JuanCarlosGuerra  
variability_seeing_20230308_0919.pngpng variability_seeing_20230308_0919.png manage 265 K 09 Mar 2023 - 04:19 JuanCarlosGuerra  
vibraion_200Hz.pngpng vibraion_200Hz.png manage 339 K 09 Mar 2023 - 09:14 JuanCarlosGuerra  