Forecast.

forecast0_20230305.png

forecast1_20230305.png

Details.

Power bump around Noon.

4:38PM/23:48(UT)

Power on WFS.

  • OCAm not live.
  • masterdiagnostic process down.
  • tryed power cycle bcu2k
  • not luck
  • set OCASm from HW gui
  • not luck
  • Stop/start adsec masterdiagnostic process
  • ocam live.
At this point it requires a restart the adsec software.
  • adsc-stoip/start
  • wfs stop/start.
  • ocam ok
  • flat.
  • 05 00:40:49.688630| MAIN > Maximum mode index used to apply flat -> # 639
Configured to MODS

If seeing improve, it will be triggered the AO. prediction is not too good from ALTA.

No AO Observations