Staff.

LBTO: Josh,Andrew,Alex,Juan Carlos

Observer: Enrico, Guido @Arcetri (remote)

Forecast.

forecast0_20230222.png

Details.

Some minor Software changes in the SoulWFS and it is good to test a close loop.

Test close loop on SX.

7:00PM

power on soulSX WFS
  • Ocam OK.
ARGOS Swing arm controller and light source in error.
  • Reset the Swing arm controller using the button in the Argos GUI.
  • OK.
  • For the light source
  • From state UNKNOWN select Turn off
  • OK.
  • Set shutter full OPen.
  • OK

TEST PRESET.

Thu Feb 23 02:29:35.813 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1674] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 02:29:35.960 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.6_L040.0_v15.0_ovfreq1700.00_sd3892.fits
  • cancel preset.
  • disturbance not running.
Repeat presetAO
  • optimize:20230223_024423
  • skipping frames.
  • no HO2 running.
  • Check autogain.conf file, it seems preset TTM
  • yes.
  • set the autogain.conf to use the ACE mode.
  • autogain.conf -> autogain.conf.ace.20230101
  • optimize:20230223_024831
  • OK
  • no skipping frames.
  • set subwindow
  • TN+Luci:20230223_025256,_025353,_025502,_025530,_025556,_025622,025915(pause-resume),_025929,_030011,_030200,_030259
  • luci dark:luci1.20230223.0010,0011.fits
  • optimize:_030441
  • TN+luci:_030631,_030657,..,030828
  • ncpa on
  • TN+luci:_030927,_030955,_031023,_031051,_031118
08:20 done with SX

power off.

876|2023-02-23 03:20:21.078400| MAIN > Turning off OCAM2K _POWER
WfsArbitrator_55076|INF| 877|2023-02-23 03:20:51.080372| MAIN > Cannot turn off OCAM2K. Reason: Timeout waiting for powerboard.L.OCAM2K_POWER.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR
WfsArbitrator_55076|ERR| 878|2023-02-23 03:20:51.080478| MAIN > Cannot turn off OCAM2K. Reason: Timeout waiting for powerboard.L.OCAM2K_POWER.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

11:45PM
  • Power on DXWFS
  • timeout bayside stages.
  • power cycle 24v->OK
  • masterdiagnostic process down.
  • ocam not live.
  • restart the masterdiagnostic process.
  • ocam live.
  • Chamber temperature 0.5C
left side primary out of range. Josh recovering it.

12:05
  • test preset.
  • mag10
  • no disturbance.
  • close loop
  • aux loop not showing any telemetry of modal or TT jitter.
  • cancel preset.
  • masterdiagnostic adsec shows error of wrong filloto.
  • mastediagnostic wfs with no errors.
  • w_stop/start_all
  • presetAO
  • auxloop shows the plots (data is coming down.)
12:26

preset + dist

Thu Feb 23 07:26:35.936 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[506] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 07:26:36.002 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits
  • optimize:20230223_073002
  • TN+luci:20230223_073206,_073257,_073341,_073411,resume,_073711,_073737,_073808
  • modalSR82
  • luci dark:ci2.20230223.0010.fits
12:30

Discuss with Enrico plan for today

Bin3 faint end. Gopt stability changing the injecting signal frequency.

Performances of Bin4 and bin3 at different frequencies, possible to optimize the best frequencies.

In case of ocam zero dump ocam command: python scripts/bcuDumpScript.py

12:50

PresetAO
  • bin3 faint end.
  • mag 16.45
  • shutter 85
Thu Feb 23 07:50:30.438 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[512] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.45,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 07:50:30.512 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits
  • luci setup: J, exp 20sec, NDIT3
  • TN+Luci:20230223-075901,_080051,,_080228,_080416,_080543,_080710
  • optimize again:_080956
1:12

Power bump.

  • adsec failure.
    20232302 08:12:29.8563 Alert: Error: COILS DISABLED
    AdSecArbitrator_109348|ERR| 712|2023-02-23 08:12:29.827715| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.

  • restart adsec_dx
  • ok
  • resart wfs soft
  • ok
  • adsec_sx
  • ok
  • setflat ->ok
  • #638 modes
  • Recovering from power bump telescope.
  • ocam in safe mode.
02:14
  • restart operations.
  • Telescope back to commercial power.
Thu Feb 23 09:16:50.542 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[515] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.45,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 09:16:50.589 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits
optimize
  • TN+luci:20230223_092737,_093002
2:35
  • shark-nir starting internal tests.
  • the TT gain could be increased the end point. Enrico changed the end point.
  • two executions of optimize and values for gain TT ddn;t change too much; 5.89, 5.45
  • TN+luci:20230223_094849,_095025,_095200,_095322,_095453,_095620
  • dark:luci2.20230223.0031.fits,luci2.20230223.0032.fits
3:03
  • change the ao table to have the injected signal lower frequency
  • aotable: table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO_20230223_500m_TESTING01.txt
u Feb 23 10:03:35.981 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[521] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.45,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 10:03:36.245 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits

  • optimize:_100716 (tt5.17),_100845(3.99)
  • prepare the 512 better for faint.
  • TN+Luci:_101241,_101430,_101646,_101833,_102012,_102211.
  • dark:uci2.20230223.0040.fits,uci2.20230223.0041.fits
  • gopt seems more stable.
  • generated a default AOtable: table_LUCIFER_ACE-AO_20230223_500m_v01.txt
3:35

preasetAO
  • bin3
  • mag 15.6
  • dist s1.5@500
Thu Feb 23 10:35:33.082 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[528] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

after check flux the dist is disabled.

!!! Caution.. !!!!

Thu Feb 23 10:37:55.017 2023 aos.info - FLAO: WFS: star found, estimated magnitude: 15.56
Thu Feb 23 10:37:55.034 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits
Thu Feb 23 10:37:55.656 2023 aos.info - Updated variable AOARB.R.LAB_MODE: 0
  • optimize:_103904(TT1.97)
  • TN+luci:_104105,_104234,_104441,_104613,_104746,104936
bin3-15p6-20230223_DX.png

3:52

Thu Feb 23 10:52:29.453 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[533] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 10:52:29.513 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.00_sd3892.fits

optmize three. _10last _105744(TT 2.59)

TN+luci:_105932,_110122,110335,_110501,_110634,_110817

04:12

presetao
  • mag 16.2
  • skip check flux.
  • Thu Feb 23 11:12:11.383 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[537] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
    Thu Feb 23 11:12:11.445 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.00_sd3892.fits
  • Optimize:_111554,_111704
  • TN+luci:_111845,__112018,_112152,_112328,_112503,_112629
4.35

presetao
  • mag 14.5
  • skip check flux
Thu Feb 23 11:35:02.940 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[539] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 11:35:03.069 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq900.00_sd3892.fits

optimize:-114042

TN+luci:_114421,_114617,_114815,_114944,_115116,_115244

04:56

preasetAO

mag 15.51

s1.5@750

skip check flux.

optimize:_115943

TN+luci:_120054,_120234,_120404,_120536,_120705,_120858

5:10

presetao
  • mag 14.49
  • keep same shutter.
  • skip check flux
Thu Feb 23 12:12:22.789 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[549] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.49,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 12:12:22.937 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits

slope commuter popup during the change of bin to 2. But it recover by itself.

!!!!! Check the log for the time events !!!!

05:12
  • close loop
  • Ocam not live
  • open loop ->ocam live
  • masterdiagnostic error messages:
MasterDiagnostic _123149|ERR| 286|2023-02-23 12:16:48.884769 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 000120CA and 00B8452A
MasterDiagnostic_123149|ERR| 287|2023-02-23 12:16:49.150700 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00012192 and 00B8452A
  • reconfigure ocam bin from the wfs control gui.
  • no luck
  • restart masterdiagnostic process WFS.
  • same behaviour.
  • Restart adsec/WFs software.
  • Adsec flat ok
5:27

PresetAO
  • mag 14.49
  • skip check flux
Thu Feb 23 12:27:41.809 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[551] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.49,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Feb 23 12:27:41.824 2023 aos.info - WFS source set to: FLAOWFS
Thu Feb 23 12:27:41.859 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits
  • Optimize:_123133,_123240
  • change the HO2 optimize range. autogain.conf.
  • TN+luci:_123824,_124204,_124339,_124506,_124628,_124811
AO table for the data today.

AO table from today results: table_LUCIFER_ACE-AO_20230223_500m_v02.txt

5:45

STOP

-- JuanCarlosGuerra - 23 Feb 2023
Topic revision: r2 - 23 Feb 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback