Staff:

LBTO: Juan Carlos

Observer: Enrico et al. (remote)

Details.

7:05am

Power on WFS

test presetAO

Tue Feb 14 14:59:02.817 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[270] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 14:59:02.837 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 14:59:02.871 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

optimize: 20230214_150428

TN:20230214_150656,_150753

08:20am

Go to faint bin4 but using a bright PSF.

shutter 100

mag 13.0

Tue Feb 14 15:20:06.082 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[273] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 15:20:06.097 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 15:20:06.206 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

  • 152837,152944,153008,_153036
  • luci setup.
  • H band
  • luci2.20230214.0013.fits
  • TN+Luci: _154848,_155014,_155147
  • dark:luci2.20230214.0020.fits,0021
  • _160345,_160506,_160618
09:08 am

preset to bin3 with the same setup as before.

Tue Feb 14 16:08:01.368 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[281] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.81,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 16:08:01.383 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 16:08:01.539 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits
  • bin3
  • 465 Hz.
  • Optmize: 20230214_161140
  • TN+Luci: _161353,161537,_161646,_161807,_161941,_162224,_162345
09:36 am

stopAO

10:00

Arcetri analysing the data.

change aotable for a test bin4.

Tue Feb 14 16:54:24.801 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[285] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 16:54:24.815 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 16:54:24.884 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits
Tue Feb 14 16:54:25.428 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

Run 3 optimize gain, the first one came bad,1

TN:_170043,_170107,_170135,_170150,_170208,

Data analysis

:_171653,_171721,_171738,_171753

10:20am

go to Bin4@1000Hz

focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 17:19:56.725 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 17:19:56.819 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

debug the optimize gain

TN:_172634,_172654,_172710,_172728,_172745,_172833

manual TT gain to have an oscillation.

Oscillation at 60Hz

oscillation of TT high TT residual rms

173403,_173423,_173439,_173451,_173505,_173528

10:38am

go to Bin3@1000Hz

Tue Feb 14 17:38:21.449 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[294] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 17:38:21.467 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 17:38:21.533 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits

optimize:20230214_174354

TN:_174529,_174545,_174602,_174615,_174627,_174642

10:51am

analysis of data.

oscillate the TT.; tt 2.63

180203,_180224,_180238,_180251,_180303,_180318,_180334.

Analysis of data.

shutter 85

mag 16.1

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 18:17:10.141 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 18:17:10.200 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits
  • adjusting the shutter to have a mag of 16.7-16.8
  • shutter 78
  • Optimize:_182518,_182629
loop open, gopt having problems, to optimize the gopt prove signal.

Tue Feb 14 18:32:19.221 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[300] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 18:32:19.237 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 18:32:19.283 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits
Tue Feb 14 18:32:19.729 2023 aos.info - FLAO: WFS: loading setup for LUCIFER

Optimize:_183551,_183641

TN:_183844,_183913,_184003,_184046,_184155,_184219

Check luci dit 30 Ndit 2

luci2.0032

TN+Luci: _184700,_184843,_185023

luci dark:0037,0038

185822,_190000,

looks like teh disturbacne not running

Tue Feb 14 19:03:02.489 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 1
Tue Feb 14 19:03:32.911 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[306] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Feb 14 19:03:32.934 2023 aos.info - WFS source set to: FLAOWFS
Tue Feb 14 19:03:33.189 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits

optimize gain:190758 wrong _190901

TN:_191107,

skip frame.

12:16PM

stop

-- JuanCarlosGuerra - 14 Feb 2023
Topic revision: r1 - 14 Feb 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.