Test plan of the software test.

1:40PM

power on WFS.
  • Bayside stage failure.
  • power cycle 24v

TEST PRESETAO

Mon Feb 13 21:06:15.366 2023 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[255] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Feb 13 21:06:15.382 2023 aos.info - WFS source set to: FLAOWFS
Mon Feb 13 21:06:15.450 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

CCD47 TIMEOUT.

on Feb 13 21:12:04.444 2023 aos.info - FLAO: WFS: preset done
Mon Feb 13 21:12:04.466 2023 aos.info - Updated variable AOARB.R.LAB_MODE: 0
Mon Feb 13 21:12:04.484 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 0

TEST NEW ENABLE RR MODE SCRIPT.

Feb 13 21:13:57.050 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 1
Mon Feb 13 21:14:08.870 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 0
Mon Feb 13 21:14:14.269 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 1

OK FLAG ON/OFF ->OK

CANCEL PRESET WITH THE NEW ENABLE ON

[AOeng@dxadsec ~]$ which new_enable_rr_mode.sh
~/live/aoroot/bin/new_enable_rr_mode.sh
[AOeng@dxadsec ~]$

on Feb 13 21:16:08.534 2023 aos.info - FLAO: WFS: preset done
Mon Feb 13 21:16:08.551 2023 aos.info - Updated variable AOARB.R.LAB_MODE: 0
Mon Feb 13 21:16:08.568 2023 aos.info - Updated variable AOARB.R.RR_ENABLED: 0

2:08

Xianyu debug.

Cancel presetAO

Restart AOarbitrator

PresetAO

enable rr mode still on

presetaAO, close loop all good.

Cancel preset.

TEst the new enable RR mode.

OK

Back to default SW version. The enable RR mode disables whe the presetAO is completed.

3PM

Argos Cal unit parked.

WFs power off.

Adsec rest.

-- JuanCarlosGuerra - 13 Feb 2023