OSURC

5:00 UT
  • Configuring for LUCI
5:22
  • Bin 2 818modes, GOPT is about 0.03
  • No NCPA, we're having a hard enough time keeping things running.
  • Seeing high and variable.
  • 20230208_052902
    20230208_052921
    20230208_052937
    20230208_052953
  • Now NCPA ON
  • 20230208_053356
    20230208_053430
    20230208_053445
    20230208_053456
  • A few safe skips
5:46
  • We had an Illumination error that lead to negative flux on the OCAM.
  • There was no bright anything.
  • 20230208_055659
  • WfsArbitrator _32849|DEB| 1165|2023-02-08 06:06:22.558937| MAIN > arbFunc doResumeLoop (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER')
    WfsArbitrator_32849|INF| 1166|2023-02-08 06:06:22.683435| MAIN > Total counts/subap: -28.483841 - framerate: 819.0 - Flux: -223
    WfsArbitrator_32849|ERR| 1167|2023-02-08 06:06:22.683536| MAIN > RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
    WfsArbitrator_32849|DEB| 1168|2023-02-08 06:06:31.929686| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.70924600000000004, 0)
    WfsArbitrator_32849|DEB| 1169|2023-02-08 06:06:31.949455| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1170|2023-02-08 06:06:41.958444| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.66486299999999998, 0)
    WfsArbitrator_32849|DEB| 1171|2023-02-08 06:06:41.975203| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1172|2023-02-08 06:06:51.984028| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.61942699999999995, 0)
    WfsArbitrator_32849|DEB| 1173|2023-02-08 06:06:51.999843| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1174|2023-02-08 06:07:02.009280| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.57372900000000004, 0)
    WfsArbitrator_32849|DEB| 1175|2023-02-08 06:07:02.026446| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1176|2023-02-08 06:07:12.035282| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.52845399999999998, 0)
    WfsArbitrator_32849|DEB| 1177|2023-02-08 06:07:12.053431| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1178|2023-02-08 06:07:22.064975| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.48253600000000002, 0)
    WfsArbitrator_32849|DEB| 1179|2023-02-08 06:07:22.087170| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1180|2023-02-08 06:07:32.096299| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.43769999999999998, 0)
    WfsArbitrator_32849|DEB| 1181|2023-02-08 06:07:32.114001| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1182|2023-02-08 06:07:42.122987| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.39201599999999998, 0)
    WfsArbitrator_32849|DEB| 1183|2023-02-08 06:07:42.141707| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1184|2023-02-08 06:07:52.151008| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.34678500000000001, 0)
    WfsArbitrator_32849|DEB| 1185|2023-02-08 06:07:52.169890| MAIN > arbFunc updateNcpaInternal done.
    WfsArbitrator_32849|DEB| 1186|2023-02-08 06:08:02.178816| MAIN > arbFunc updateNcpaInternal (<AdOpt.thAOApp.thAOApp instance at 0x4011680>, 'FLAOWFS', 'LUCIFER', 0.30151, 0)

06:41
  • Closed loop again.
  • 20230208_070222
    20230208_070240
    20230208_070251
    20230208_070303

Added by DMiller on 20230208

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq emGain gain mod nph/sa/fr Gopt AntiDrift SR SR (from slopes) FWHM [max,min] (mas) filter exp #frames disturb SN skip notes
20230208_052902 ??? 15.7 40 7 -1.00   2 -1 818 600 -1.0 -1.0 -1.0 3 0.7 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0 - Pupils not on target
20230208_052921 ??? 13.6 40 7 2.00 125000 2 250 818 600 0.1 0.0 0.0 3 4.3 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0 - Pupils not on target
20230208_052937 ??? 13.7 40 7 2.08 125000 2 250 818 600 0.1 0.0 0.0 3 3.8 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_052953 ??? 13.6 40 7 2.21 125000 2 250 818 600 0.1 0.0 0.0 3 4.3 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_053356 ??? 13.6 40 7 1.81 125000 2 250 818 600 0.1 0.0 0.0 3 4.3 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_053430 ??? 13.7 40 7 1.90 125000 2 250 818 600 0.1 0.0 0.0 3 4.0 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0 - Pupils not on target
20230208_053445 ??? 13.6 40 7 1.94 125000 2 250 818 600 0.1 0.0 0.0 3 4.2 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_053456 ??? 13.7 40 7 2.21 125000 2 250 818 600 0.1 0.0 0.0 3 3.8 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_055659 ??? NaN 40 8 0.01 125000 2 250 786 600 0.0 -1.0 -1.0 3 -1.1 1.00 OFF -1.0 -100.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_070222 ??? 16.8 37 7 -1.00   2 -1 813 600 -1.0 -1.0 -1.0 3 0.2 0.04 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0 - Pupils not on target
20230208_070240 ??? 13.6 37 8 1.45 125000 2 250 813 600 0.1 0.0 0.0 3 4.1 0.04 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0 - Pupils not on target
20230208_070251 ??? 13.6 37 8 1.79 125000 2 250 813 600 0.1 0.0 0.0 3 4.3 0.04 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  
20230208_070303 ??? 13.6 36 7 1.75 125000 2 250 813 600 0.1 0.0 0.0 3 4.4 0.03 OFF -1.0 -1.0 [-1, -1] ? -1 -1 ONSKY NO 0  

-- GregoryTaylor - 08 Feb 2023
Topic revision: r3 - 09 Feb 2023, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.