Staff:

LBTO: Guido,Xianyu, Brandon, Juan Carlos

Summary.

Test new version of the housekeeper.

Link to the test spreed sheet.

LINK

https://docs.google.com/spreadsheets/d/13O51ItEb5kcc7-9-RUlKQwxt-GLcjs0DjDYFz80RJfA/edit?usp=sharing

Details.

Center pupils.

Failed just close the loop.

fastdiagn_68345 |WAR| 778258|2023-01-31 17:24:36.831392| MAIN > Timeout - Will emergencyReact next loop [FastDiagnostic.cpp:1090]
fastdiagn_68345 |WAR| 778259|2023-01-31 17:24:38.832282| MAIN > Timeout - Will emergencyReact now [FastDiagnostic.cpp:1085]
fastdiagn_68345 |ERR| 778260|2023-01-31 17:24:38.832306| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]
fastdiagn_68345 |INF| 778261|2023-01-31 17:24:38.832323| ADAM-MODBUS > AdamModbus: disabling coils...

6 Alert: Error: COILS DISABLED
AdSecArbitrator_68399|INF| 116|2023-01-31 17:23:25.970870| ALERTHANDLER > Received from masterdiagnostic.R a DumpSaved alert with filename /home/aoeng/soul/aolog/2023/01/31/ADAPTIVE-SECONDARY_00001675185805_20230131_172325.bin
AdSecArbitrator_68399|INF| 117|2023-01-31 17:23:25.970886| ALERTHANDLER > Processdump is skipped
20233101 17:23:25.9714 Alert: DumpSaved: DumpSaved vector ready

ALL DSP boards expired before the fastdiagn.

Switch BCU didn;t responds.

Housekeeper running ....SW

adsc_stop/start.

w_stop/start_all

1 17:39:23.844 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1727] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.03[0.03],roy:0.01,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Jan 31 17:39:23.859 2023 aos.info - WFS source set to: FLAOWFS

Close loop OK

TN:20230131_175010.

increase hgain ok

_175341

OK

close loop OK.

10:58am

WFS power off.

adsec power off.

change to default Adsec SW version.

PresetAO

18:26:01.952857| MAIN > Timeout error on baysidex (-5001) TIMEOUT_ERROR

Tue Jan 31 18:28:46.033 2023 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[1736] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:1700 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Tue Jan 31 18:28:58.436 2023 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[1737] Mode: Move stages, Automatic acquire

OK.

TN:_183627

ramp gains to: 0.4,0.1,0.05

_183846

close loop stable.

11:48am

power off.

rest shell

park argos cal unit.

-- JuanCarlosGuerra - 31 Jan 2023
Topic revision: r1 - 31 Jan 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.