Details.

8:00AM

Power on WFS.

ocam

ok

Dome shutter has a problem to close.

Mean time to work in the setup of the WFS.

Build a IIR filter for Bin2 for the rec 20230120_192846

edit file: /home/AOeng/IIR4LBT/main_from_iir_to_LBT.pro
  • fsample: 1700
  • Bin2
  • outdir = '/home/AOeng/IIR4LBT/'
  • if bin eq 2 then recOutFileName = 'Rec_20230120_000003.fits'
if bin eq 2 then begin
if KLversion eq 'KL_v29' then inRecMatFname = 'adsec_calib/M2C/KL_v29/RECs/Rec_20230120_192846.fits' ;bin 2, 200 modes

The frequency sampling is not important for the generation of the REC. it keeps fsample=1700

ao table :

table_LUCIFER_ACE-AO_20230126_v01.txt

16:55 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO_20230126_v01.txt

9:52am
Still waiting for the shutter.

setting up the disturbance:

disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits"

10:09am

shutter door closed.

Proceeding with the soulDX checkouts.

Argos cal unit deployed.

Adse cflat.

-26 17:16:15.116192| MAIN > Maximum mode index used to apply flat -> # 483

Acquire a TV dark

timeout. CCD47 not live.

Change bin from CCD47 HW gui.

The change binning executes a reset of the BCU47

ok

10:22am

Fabio going home.
  • left the ocam check process running. automatic dump saver.
  • If something happen with the ocam save TN.
  • he will connect later with the loop closed to have a reference ocam dump.
check preset.

Thu Jan 26 17:21:48.060 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

Fabio note:
  • for the slopes zero execute the reset_gopt.sh from /live/source
Cancel preset. open loop, the PSF diverge during the center pupils
  • BCU47 temperature 0.5 (camera lens), is it too cold..?
  • water temp:-8
  • The SX side has the warning alarm that the center pupil can not be operated if temperature is below 7C. Is this applied to DX?
10:50am
  • shutter 105
  • mag 12.7
Thu Jan 26 17:51:00.033 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1302] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.71,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 26 17:51:00.122 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

Open loop.

cancel preset.

The loop diverge as soon as the TT is closed.

it was tested with the Bin1 rec and Bin2 rec. it behaves the same.

stop......

let's think about it.
  • Adsec has the default sw version. confirm
  • Contacted Xianju, he will join in about 20m.

close loop again and save a TN:

20230126_183717
  • checking other reconstructor for Bin1 and it behaves the same.
  • to have a clean restart.
12:45PM

adsc_stop

wfs stop/start

adsec flat.

6 19:52:02.897377| MAIN > Maximum mode index used to apply flat -> # 530

12:56PM

mag 12.71

shutter 105

Thu Jan 26 19:56:35.145 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1311] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.71,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

loop close OK.

No issues.

PresetAO


Thu Jan 26 20:24:18.305 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1313] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.71,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Thu Jan 26 20:24:18.367 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits

center pupil

ok.

optimize.
  • skip frame.
  • open loop
  • second try.
  • skip failed.
  • Adsec failure.
itrator_17045|INF| 303|2023-01-26 20:30:08.432508| MASTDIAGN > Command returns success .
AdSecArbitrator_17045|INF| 304|2023-01-26 20:30:09.841290| COMMANDHANDLER > Command Run Ao (code 2014) successfully completed
AdSecArbitrator_17045|INF| 305|2023-01-26 20:30:09.841826| MAIN > Received cmd: LoadGain (VEC[672],0)
AdSecArbitrator_17045|INF| 306|2023-01-26 20:30:09.842202| COMMANDHANDLER > FSM (status: AORunning) has received command 2018 (SetGain)
AdSecArbitrator_17045|INF| 307|2023-01-26 20:30:09.880887| COMMANDHANDLER > Command SetGain (code 2018) successfully completed
AdSecArbitrator_17045|INF| 308|2023-01-26 20:30:09.885524| MAIN > Received cmd: Offloading(1)
AdSecArbitrator_17045|INF| 309|2023-01-26 20:30:09.885567| COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_17045|INF| 310|2023-01-26 20:30:09.886601| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_17045|ERR| 311|2023-01-26 20:30:27.791710| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_17045|ERR| 312|2023-01-26 20:30:27.791756| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.R
20232601 20:30:27.7925 Alert: Error: COILS DISABLED

20232601 20:30:27.8499 Alert: DumpSaved: DumpSaved vector ready

Adsec flat

-26 20:40:05.789482| MAIN > Maximum mode index used to apply flat -> # 526

Thu Jan 26 20:44:11.803 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1316] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.4,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 26 20:44:11.883 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits

  • center start ok
  • center pupil ok
  • close loop ok
  • optimize gain 20230126_204751
  • no skip frames.
  • TN:20230126_204956
  • modalSR 50
  • mag started 14.7 and went to 14.1
pause.

adjust shutter

shutter 91

mag to 4.4

resume

_205841

luci exp 6sec.

_210125

AdSecArbitrator _24415|INF| 236|2023-01-26 21:01:25.506007| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_24415|WAR| 237|2023-01-26 21:02:44.647703| MAIN > Skip frame detected!
AdSecArbitrator_24415|ERR| 238|2023-01-26 21:02:44.766087| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator _24415|ERR| 239|2023-01-26 21:02:44.766150| ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.R

adsc_stop/start

6 21:09:15.940989| MAIN > Maximum mode index used to apply flat -> # 546

check a Bin1.

Thu Jan 26 21:15:13.594 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1323] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 26 21:15:13.658 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits

  • TN:_210234 with disturbance and LNgain.
  • optimize gain 20230126_212146
  • gopt ok
  • TN:_212352
  • loop stable as before...
mag 14.4

Thu Jan 26 21:28:10.038 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1328] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.4,cindex:0.14,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Jan 26 21:28:10.053 2023 aos.info - WFS source set to: FLAOWFS
Thu Jan 26 21:28:10.098 2023 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits

luci exp 5

nexp 10

optmize gain failed.-> adsec failure.

second pass

AdSecArbitrator _30561|INF| 265|2023-01-26 21:32:31.321351| SERIALIZATION > > disturbActive: ON
AdSecArbitrator_30561|INF| 268|2023-01-26 21:32:31.321467| COMMANDHANDLER > FSM (status: Failure) has received command 2019 (Set disturb)
Last message repeated
AdSecArbitrator_30561|ERR| 269|2023-01-26 21:32:31.321499| COMMANDHANDLER > adsecarb: Fsm is discarding command 2019 (Set disturb)...
AdSecArbitrator_30561|WAR| 270|2023-01-26 21:32:31.321569| MAIN > LoadDisturbTag: WARNING - adsecarb:Illegal command for state Failure (Set disturb)
AdSecArbitrator_30561|ERR| 271|2023-01-26 21:32:32.401614| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_30561|ERR| 272|2023-01-26 21:32:32.401683| ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.R
20232601 21:32:32.4025 Alert: Error: COILS DISABLED
AdSecArbitrator_30561|ERR| 273|2023-01-26 21:32:33.019032| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_30561|ERR| 274|2023-01-26 21:32:33.019057| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.R
20232601 21:32:33.0197 Alert: Error: COILS DISABLED

2:56PM

Stop

Adsec rest.

WFS power off.

-- JuanCarlosGuerra - 26 Jan 2023
Topic revision: r1 - 26 Jan 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.