2:53
  • WFS arbitrator process died. I can't restart it so I'm cycling the processes.
  • WfsArbitrator _23105|INF| 61|2023-01-18 02:51:46.041108| MAIN > Camera lens tracking: moving by x= -0.2 y= -1.5 (um)
    WfsArbitrator_23105|INF| 62|2023-01-18 02:51:59.370256| MASTDIAGN > Setting master diagnostic in open loop mode
    WfsArbitrator_23105|WAR| 63|2023-01-18 02:52:27.757595| WFS > Command returns retryable error : RETRY: Error in acquire ref: Reading shared buffer masterdiagnostic.R:OPTLOOPBUF - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR
    WfsArbitrator_23105|ERR| 64|2023-01-18 02:52:41.856593| SERIALIZATION > Loop frequency 0.0 is out of range (valid values: 30.0 - 2000.0
    WfsArbitrator_23105|WAR| 65|2023-01-18 02:52:41.856642| COMMANDHANDLER > Command validation failed:
    WfsArbitrator_23105|ERR| 66|2023-01-18 02:53:31.757882| COMMANDHANDLER > wfsarb: Fsm is discarding command 2023 (EnableDisturb)...
    WfsArbitrator_23105|WAR| 67|2023-01-18 02:53:31.757943| MAIN > EnableDisturbance: WARNING - wfsarb:Illegal command for state AOSet (EnableDisturb)
    WfsArbitrator_23105|INF| 68|2023-01-18 02:53:36.084215| MAIN > Received cmd: centerPupils()
    WfsArbitrator_23105|ERR| 69|2023-01-18 02:53:36.084278| COMMANDHANDLER > wfsarb: Fsm is discarding command 2039 (centerPupils)...
    WfsArbitrator_23105|WAR| 70|2023-01-18 02:53:36.084314| MAIN > centerPupils: WARNING - wfsarb:Illegal command for state AOSet (centerPupils)

Angle Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11 TN
0 -19 -20 -20 -10 0 10 -10 -3.2 20230117_044358
30 -15.7 30 -20 -10 -10 5 -5 -3.2 20230117_050300
60 -8.9 45 20 -5 -20 -5 0 -3.2 20230117_051805
90 -0.3 10 40 10 -20 -5 0 -3.2 20230117_053511
120 7.7 -20 25 10 -15 5 -5 -6.9 20230117_054635
150 13.2 -20 20 10 0 0 0 -8.5 20230118_033644
180 14.2 -10 -10 10 10 5 5 -9.7 20230118_034935
210 10.8 -10 -10 10 10 -10 0 -10.2 20230118_040042
240 3.9 0 0 -15 15 0 -5 -9.3 20230118_041041
270 -4.6 10 10 -10 15 10 0 -8 20230118_042158
300 -12.7 -20 20 -20 10 -5 15 -6.3 20230118_043038
330 -17.5 -40 -30 -20 0 -15 -10 -4.6 20230118_044654
-- GregoryTaylor - 18 Jan 2023