Staff:

LBTO:David,OLga, Juan Carlos

Observer: INAF (Felice)remote Italy

Forecast.

forecast-20230401_0.png

forecast-20230401_1.png

forecast-20230401_2.png

forecast-20230401_3.png

Details.

06:15

Power on

Ocam OK

flat:

01:16:29.582657| MAIN > Maximum mode index used to apply flat -> # 639

Execute nudge predictor.

./nudgepredict.py -d 20230329 -e 12 -b 6

[lbto@obs1 ObserverSupport ]$ ./nudgepredict.py -d 20230402 -e 12 -b 12
5187110400.0 start MJD sec using backhour 12.0
20230402 is the day to be plotted.
0.0 start hour using backhour 12.0 end hour 12.0
These UT start times will have a nudge if the telescope is tracking.
00:07:54
00:42:02
01:16:10
01:50:18
02:24:26
02:58:34
03:32:42
04:06:50
04:40:58
05:15:06
05:49:14
06:23:22
06:57:30
07:31:38
08:05:46
08:39:54
09:14:02
09:48:10
10:22:18
10:56:26
11:30:34


06:43
  • EL to 30 for opening.
  • SAving ocam frames.
  • TN:20230401_015204
  • after a dark.
  • TN:_015418,_015516
WFS masterdiagn:

master_wfs-20230401.png

ADSEC master:

MasterDiagnostic _3434|WAR| 822|2023-04-02 01:43:46.276992| BCUSWITCH > FramesDownloader BCUSWITCH: [InvalidDiagnosticPacketException] Unexpected packetId 3 for frameId 190 (instead of packetId 0 for frameId 190).

07:01
  • lcui authorize at 30 degrees elevation.
dl_3543 |INF| 1268|2023-04-02 02:02:02.259497| MAIN > Cleaned last slopes command.
idl_3543 |INF| 1269|2023-04-02 02:02:02.259562| MAIN > Modes out of safe range ID: # 45
idl_3543 |INF| 1270|2023-04-02 02:02:02.259606| MAIN > Commands out of safe range ID: # -1
idl_3543 |INF| 1271|2023-04-02 02:02:02.259628| MAIN > Forces out of safe range ID: # -1
idl_3543 |INF| 1272|2023-04-02 02:02:02.259646| MAIN > SafeSkipFrames caused by modes out of range detected.
idl_3543 |INF| 1273|2023-04-02 02:02:02.259662| MAIN > Recovery from any SafeSkipFrames started...
idl_3543 |INF| 1274|2023-04-02 02:02:02.259679| MAIN > Getting info on actual mirror position...
idl_3543 |INF| 1275|2023-04-02 02:02:02.263242| MAIN > Reconstructor filter cleaning...
idl_3543 |INF| 1276|2023-04-02 02:02:02.269019| MAIN > Control current integrator cleaning up...
idl_3543 |INF| 1277|2023-04-02 02:02:02.289389| MAIN > Null new delta command contribution
idl_3543 |INF| 1279|2023-04-02 02:02:02.291857| MAIN > Restore old oversampling...
idl_3543 |INF| 1280|2023-04-02 02:02:02.299204| MAIN > Done.
idl_3543 |INF| 1281|2023-04-02 02:02:02.364052| MAIN > Restore control current integrator action....
idl_3543 |INF| 1282|2023-04-02 02:02:02.408211| MAIN > Done.
idl_3543 |INF| 1283|2023-04-02 02:02:02.409536| MAIN > All Done. Succefully recovered from SafeSkipFrames.
idl_3543 |INF| 1284|2023-04-02 02:02:03.137693| MAIN > Loading shape: /local/aomeas/adsec_calib/flat/Applicable/LUCIFER.sav
idl_3543 |INF| 1285|2023-04-02 02:02:03.139335| MAIN > Selected flat: /local/aomeas/adsec_calib/flat/Applicable/LUCIFER.sav
idl_3543 |INF| 1286|2023-04-02 02:02:03.985646| MAIN > The threshold has been moved to 0.2 as the total forces are included in the computation of the modal filtering.
idl_3543 |INF| 1287|2023-04-02 02:02:03.985700| MAIN > The threshold has been additionally moved to 0.5 to try flattening better the external edge.
idl_3543 |INF| 1288|2023-04-02 02:02:03.985740| MAIN > Delta command modal filtering for reducing peak force to 0.30 [N]
idl_3543 |INF| 1289|2023-04-02 02:02:04.018014| MAIN > total current added in the force vector for the computation of the modal filtering
idl_3543 |INF| 1290|2023-04-02 02:02:04.027415| MAIN > Maximum mode index used to apply flat -> # 270

AOS.

Sun Apr 2 02:02:01.812 2023 aos.info - Selected arbitrator: FLAO
Sun Apr 2 02:02:01.848 2023 aos.info - Flat set to: LUCIFER
Sun Apr 2 02:02:01.881 2023 aos.PresetFlat.started - PresetFlat [86] (flat:LUCIFER)
Sun Apr 2 02:02:04.575 2023 aos.PresetFlat.complete - PresetFlat [86]
Sun Apr 2 02:03:44.040 2023 aos.Stop{FLAO}.started - Stop{FLAO}[87] (msg:Starting Preset)
Sun Apr 2 02:03:44.054 2023 aos.Stop{FLAO}.complete - Stop{FLAO}[87]

07:15

OSCO

Sun Apr 2 02:12:01.568 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[90] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:-2.99182[-2.99182],soy:2.99182,rox:-2.97658[-2.97658],roy:2.9952,mag:7.51,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Apr 2 02:12:01.580 2023 aos.info - WFS source set to: FLAOWFS
  • TARGET REROTATOR OUT OF RANGE IN THE AOPREPRARE.
Sun Apr 2 02:14:28.535 2023 aos.error - AO rotator out of allowed range
Sun Apr 2 02:14:33.818 2023 aos.info - FLAO: WFS: preset done
Sun Apr 2 02:14:33.818 2023 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[92] - [AOException] Rerotator tracking out of ramge
  • LFBG ROT -15
Sun Apr 2 02:14:28.535 2023 aos.error - AO rotator out of allowed range
Sun Apr 2 02:14:33.818 2023 aos.info - FLAO: WFS: preset done
Sun Apr 2 02:14:33.818 2023 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[92] - [AOException] Rerotator tracking out of ramge
  • SEND THE PRESET AGAIN.
  • CANCEL PRESET.
  • THE PUPILS LOOKS LIKE A JUMPNG IMAGE UP/DOWN.
  • POWER CYCLE BCU2K
  • GOOD NOW.
  • OPTIMIZE:20230402-023240
  • NCPA ON
oSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023548/wfs.fits')
WfsArbitrator_3132 |DEB| 578|2023-04-02 02:35:50.017679| MAIN > getSetupFits(): fits header created
WfsArbitrator_3132 |DEB| 579|2023-04-02 02:35:50.073589| MAIN > arbFunc doSaveStatus done.
WfsArbitrator_3132 |DEB| 580|2023-04-02 02:35:58.735389| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.815799999999999, 0)
WfsArbitrator_3132 |DEB| 581|2023-04-02 02:35:58.757336| MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_3132 |DEB| 582|2023-04-02 02:36:04.002775| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023602/wfs.fits')
WfsArbitrator_3132 |DEB| 583|2023-04-02 02:36:04.011179| MAIN > getSetupFits(): fits header created
WfsArbitrator_3132 |DEB| 584|2023-04-02 02:36:04.038482| MAIN > arbFunc doSaveStatus done.
WfsArbitrator_3132 |DEB| 585|2023-04-02 02:36:08.774483| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.755199999999999, 0)
WfsArbitrator_3132 |DEB| 586|2023-04-02 02:36:08.794529| MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_3132 |DEB| 587|2023-04-02 02:36:16.003276| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023614/wfs.fits')

...


WfsArbitrator_3132 |DEB| 616|2023-04-02 02:37:16.920044| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023712/wfs.fits')
WfsArbitrator_3132 |DEB| 619|2023-04-02 02:37:19.056370| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.330400000000001, 0)
WfsArbitrator_3132 |INF| 622|2023-04-02 02:37:20.352625| MAIN > Total counts/subap: 185.203065 - framerate: 1700.0 - Flux: 95398
WfsArbitrator_3132 |DEB| 626|2023-04-02 02:37:32.001591| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023730/wfs.fits')
WfsArbitrator_3132 |DEB| 629|2023-04-02 02:37:39.137848| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.210799999999999, 0)
WfsArbitrator_3132 |DEB| 631|2023-04-02 02:37:49.176502| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.150099999999998, 0)
WfsArbitrator_3132 |DEB| 633|2023-04-02 02:37:49.305672| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023742/wfs.fits')
WfsArbitrator_3132 |DEB| 636|2023-04-02 02:37:59.216300| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 28.086300000000001, 0)
WfsArbitrator_3132 |DEB| 637|2023-04-02 02:37:59.241503| MAIN > arbFunc updateNcpaInternal done.
WfsArbitrator_3132 |DEB| 638|2023-04-02 02:38:02.002449| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_023800/wfs.fits')
WfsArbitrator_3132 |DEB| 667|2023-04-02 02:40:19.670851| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 27.253799999999998, 0)
WfsArbitrator_3132 |DEB| 669|2023-04-02 02:40:27.008274| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_024025/wfs.fits')
WfsArbitrator_3132 |DEB| 672|2023-04-02 02:40:29.699020| MAIN > arbFunc updateNcpaInternal (, 'FLAOWFS', 'LUCIFER', 27.1952, 0)
WfsArbitrator_3132 |DEB| 674|2023-04-02 02:40:39.002959| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20230402/Data_20230402_024037/wfs.fits')

  • GOPT STABLE.
  • LUCI1.20230402.
07:40
  • MOVE TO SCIENCE TARGET.
Sun Apr 2 02:46:53.947 2023 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[108] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:956 mag:0 nBins:2 nModes:250 r0:nan snMode:0 strehl:0 ttMod:0
  • bin2.
13.5
  • optimize:_025017
  • loop open
AdSecArbitrator _3734|WAR| 475|2023-04-02 02:53:56.227234| MAIN > Skip frame detected! (107.96% of frames skipped.)
AdSecArbitrator_3734|WAR| 476|2023-04-02 02:53:56.227391| MAIN > Maximum skip frames reached: 107.96% of frames sk
  • and reclose with FLAO
  • optimize
  • _025415
  • gopt again
  • one clcik up in TT->0.19 to 0.24.
  • to check the low TT gain?
07:59
  • loop open
  • optimize:_025858
  • modal SR 44%
  • TN:_030726,_030751
  • TT gain 0.4,0.19,0.11
  • 08:15
  • dimm 1.2
  • TN:_031510
next nudge
3:32:42 08:31
  • LUCI IN PAUSE.
  • WFS PAUSE.
Sun Apr 2 03:31:25.931 2023 aos.info - AO loop closed
Sun Apr 2 03:31:25.931 2023 aos.Pause{FLAO}.complete - Pause{FLAO}[86]
  • WAIT FOR THE NUDGE.
  • OBSERVED STAR MOVED IN THE CCD47 ABOUT 5ARCSEC BACK TO HOTSHPOT.
  • RESUME WFS
Sun Apr 2 03:33:26.728 2023 aos.Resume{FLAO}.started - Resume{FLAO}[86]
Sun Apr 2 03:33:26.874 2023 aos.info - AO loop closed
Sun Apr 2 03:33:26.874 2023 aos.Resume{FLAO}.complete - Resume{FLAO}[8
  • RESUME LUCI
  • went well.
  • next nudge: 04:06:50
  • TN:_033514
  • dimm 1.4"-1.6"
  • variable seeing.
seeing-20230402_0839.png

TN:_034114.
  • seeing up to 1.8"
  • TN:_034704
  • seeing up to 2"
08:49
  • luci pause
  • seeing1.8
  • optimize gan:_034933
  • TN:_035226
  • chek the optimize for bad seeing it stops the ho1
08:55
  • seeing 1.2"
  • TN:_035527
  • TN:_035655 ttg:0.3
  • luci pause.
  • pause WFS
  • REsume after nudge
Sun Apr 2 03:33:26.728 2023 aos.Resume{FLAO}.started - Resume{FLAO}[86]
Sun Apr 2 03:33:26.874 2023 aos.info - AO loop closed
Sun Apr 2 03:33:26.874 2023 aos.Resume{FLAO}.complete - Resume{FLAO}[8
  • OK after nudge.
  • TN:_040829
  • next nudge: 4:40:58
  • TN:_041207
  • alta prediction.
alta-seeing_forecast20230402.png

09:15

loop open (?)

04:14:30.562279| MAIN > Camera lens tracking: AdSec is skipping frames, camera lens not moving

04:13:34.506157| MAIN > Status after command: LoopClosed
python_3768 |INF| 719|2023-04-02 04:14:31.215443| MAIN > Loop fault detected. Opening loop.
python_3768 |INF| 720|2023-04-02 04:14:34.312914| MAIN > ... 1 equal lines suppressed
python_3768 |ERR| 721|2023-04-02 04:14:34.312966| MAIN > Alert from AdSec [177] - SkipFrame
python_3768 |DEB| 722|2023-04-02 04:14:34.313003| MAIN > Sending to 3 clients: SkipFrame

04:13:34.505787| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_3734|WAR| 1240|2023-04-02 04:13:50.495285| MAIN > Skip frame detected! (0.11% of frames skipped.)
AdSecArbitrator_3734|WAR| 1241|2023-04-02 04:14:27.139349| MAIN > Skip frame detected! (0.11% of frames skipped.)
AdSecArbitrator _3734|WAR| 1242|2023-04-02 04:14:29.164806| MAIN > Skip frame detected! (12.06% of frames skipped.)
AdSecArbitrator _3734|WAR| 1243|2023-04-02 04:14:30.208228| MAIN > Skip frame detected! (107.85% of frames skipped.)
AdSecArbitrator_3734|WAR| 1244|2023-04-02 04:14:30.208344| MAIN > Maximum skip frames reached: 107.85% of frames skipped. Will alert ICE clients.
AdSecArbitrator_3734|WAR| 1245|2023-04-02 04:14:31.215146| MAIN > Skip frame detected! (107.62% of frames skipped.)
AdSecArbitrator_3734|WAR| 1246|2023-04-02 04:14:31.215248| MAIN > Maximum skip frames reached: 107.62% of frames skipped. Will alert ICE clients.
AdSecArbitrator_3734|INF| 1247|2023-04-02 04:14:31.218327| MAIN > Received cmd: StopAo (1)

  • reclose flao gui
  • optimize:_041517
  • low value for the TT. 0.07
  • increase to 0.36
  • high performance.
  • TN:_041747
  • seeing 1.22"
  • TN:_043004
09:40:20

luci pause.

WFS pause.

un Apr 2 04:40:25.287 2023 aos.info - HO offload command end
Sun Apr 2 04:40:27.772 2023 aos.info - TTF offload command end
Sun Apr 2 04:41:06.289 2023 aos.Resume{FLAO}.started - Resume{FLAO}[86]
Sun Apr 2 04:41:06.424 2023 aos.info - AO loop closed
Sun Apr 2 04:41:06.424 2023 aos.Resume{FLAO}.complete - Resume{FLAO}[86]
Sun Apr 2 04:41:06.937 2023 aos.info - TTF offload: previous 1 requests ignored
  • OK
  • TN:_044204
  • dimm:1.2"
  • next nudge: 05:15
  • TN:_044924
  • TN:_045815
  • seeing :1"
  • TN:_045945
  • full corrections. !! POWER !!
  • TN:_050647

  • TO INVESTIGATE A FLAT GOPT (?) BEFORE A PAUSE.
  • TN:_051248
  • NUDGE, SCAPE IT.
  • LOOP OPEN due to skip frame.
  • RECLOSE
  • OPTIMIZE :_051634
  • GOPT
  • seeing 1.
  • TN:_051834
  • ncpaon
  • TN:_051919
10:21
  • seeing going up 1.4
  • TN:_052158
  • next nudge: 05:49:14
  • New positions.
  • Optimize:_053518
  • TN:_053849
  • seeing 1.32
  • TN:_054150
  • TN:_054310
loop open miss nudge pause.
  • Observer took a bit time after the nudge happen.
  • reclose
  • optimize:_054937
  • TN:_055201
next nudge: 06:23 10:55
  • seeing 1.11"
  • TN:_060115
  • tip ttgain one click: tt0.31
  • TN:_060236
  • TN:_060347
11:20
  • loop open
  • seeing blown up.
  • optimize:_062044
11:22
  • seeing 1.5"
  • wfs pause for nudge
  • luci pause.
11:26
  • 12.9 degrees from moon.
  • TN:_062717
  • loop not correcting.
  • rerot at the limit.
11:29

11:40 loop open
  • skiping frame
  • get a new rot angle.
  • observer changing rot angle.
  • cancel preset.
Sun Apr 2 06:44:59.500 2023 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[527] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:-1.79509,rox:-9.16667[-9.16667],roy:4.15779,mag:13.15,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sun Apr 2 06:44:59.513 2023 aos.info - WFS source set to: FLAOWFS
  • seeing 1.6"
  • optimize:_064802
  • TN:_065115
  • TN:_065307
Sun Apr 2 06:56:50.851 2023 aos.Pause{FLAO}.started - Pause{FLAO}[86]
Sun Apr 2 06:56:51.028 2023 aos.info - AO loop closed
  • ok the resume.
next nudge: 07:31
  • TN:_070426
  • loop seems stuck
  • TN:_071942
  • TN:_072230
Sun Apr 2 07:30:42.456 2023 aos.Pause{FLAO}.started - Pause{FLAO}[86]
Sun Apr 2 07:30:42.624 2023 aos.info - AO loop closed
Sun Apr 2 07:30:42.624 2023 aos.Pause{FLAO}.complete - Pause{FLAO}[86]

12:38
  • EL45
  • sky not good, not good corrections. Observer decided to no continue.
  • done with AO
  • going to seeing limited.

Power off WFS

-- JuanCarlosGuerra - 02 Apr 2023
Topic revision: r2 - 04 Apr 2023, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.