20221230_SX_Night Closed Dome: SX Super-ESM Reconstructors

Full AO Table: table_LUCIFER_ACE-AO.txt.20221206

# 0    1      2   3     4      5      6                7                          8                 9    10       11       12       13        14    15     16      17         18        19        20     21    22
Rmag   flux   bin freq  emGain base   rec              filtering                  pupils            tt   fw1_acq  fw2_acq  fw1_obs  fw2_obs   TVbin TVfreq TVavg   TVflux CL->freq     emG  GOpt->mode   amp  freq

-1.5 1.054E9  1  1700  1       KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    3         2       0        2         4     4.3     20     1250000     200        1        30    10e-9  80.0
0.0   2.65E8  1  1700  1       KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    3         2       0        2         4     4.3     20     1250000     200        1        30    10e-9  80.0
3.5  10.54E6  1  1700  10      KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    3         2       0        2         4     4.3     20       15000     200        1        30    10e-9  80.0
4.5   4.20E6  1  1700  25      KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        2         4     4.3     20       15000     200        3        30    10e-9  80.0
5.5   1.67E6  1  1700  64      KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        2         4     4.3     20        5000     200        6        30    10e-9  80.0
6.5   6.65E5  1  1700  163     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        2         4     4.3     20        2000     200       12        30    10e-9  80.0
7.5   2.65E5  1  1700  410     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        2         4     4.3     20         800     200       25        30    10e-9  80.0
8.5   1.05E5  1  1700  600     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        2         4     4.3     20         800     200       50        30    10e-9  80.0
9.5   4.20E4  1  1700  600     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         2       0        1         4     4.3     20         800     200      100        30    10e-9  80.0
10.5  1.67E4  1  1700  600     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         1       0        1         4     4.3     20         800     200      300        30    10e-9  80.0
11.4  7.30E3  1  1350  600     KL_v20 20190930_161000  iir1700HzV003              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
11.4  7.30E3  1  1350  600     KL_v20 20190930_161000  iir1350HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
11.7  5.53E3  1  1000  600     KL_v20 20190930_161000  iir1350HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
11.7  5.53E3  1  1000  600     KL_v20 20190930_161000  iir1000HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
12.5    2648  1   750  600     KL_v20 20190930_161000  iir1000HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
12.5    2648  1   750  600     KL_v20 20191213_000000  iir0750HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
12.7    2202  1   625  600     KL_v20 20191213_000000  iir0750HzV001              20181103_001410   3    4         1       0        1        16     12.6    20         800     200      600        30    10e-9  80.0
12.7    2202  2  1250  600     KL_v20 20191011_125000  iir1350HzV001              20220901_074516   3    4         1       0        1        16     12.6    20         300     200      600        30    15e-9  80.0
13.0    1671  2  1000  600     KL_v20 20191011_125000  iir1000HzV003              20220901_074516   3    4         1       0        1        16     12.6    20         300     200      600        30    15e-9  80.0
14.0     665  2   800  600     KL_v20 20191011_125000  iir1000HzV003              20220901_074516   3    4         1       0        1        16     12.6    20         300     200      600        30    15e-9  80.0
14.5     420  2   750  600     KL_v20 20191011_125000  iir1000HzV003              20220901_074516   3    4         1       0        1        16     12.6    20         300     200      600        30    15e-9  80.0
14.5     420  3  1000  600     KL_v20 20200922_150000  iir1000HzV004              20220901_070135   3    4         1       0        1        16     12.6    20         300     200      600        30    20e-9  80.0
15.5     167  3   750  600     KL_v20 20200922_150000  iir1000HzV004              20220901_070135   3    4         1       0        1        16     12.6    50         300     200      600        30    20e-9  80.0
15.5     167  3   750  600     KL_v20 20200922_150000  iir0750HzV003              20220901_070135   3    4         1       0        1        16     12.6    50         300     200      600        30    20e-9  80.0
15.8     135  3   500  600     KL_v20 20200922_150000  iir0750HzV003              20220901_070135   3    4         1       0        1        16     12.6    50         300     200      600        30    20e-9  80.0
15.8     135  3   500  600     KL_v20 20200922_153500  forgettingFactorBin4v2SOUL 20220901_070135   3    4         1       0        1        16     12.6    50         100     200      600        30    20e-9  80.0
16.5      67  3   250  600     KL_v20 20200922_153500  forgettingFactorBin4v2SOUL 20220901_070135   3    4         1       0        1        16     12.6    50         100     200      600        30    20e-9  80.0
16.5      67  4   500  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50         100     200      600        30    30e-9  45.0
17.1    38.3  4   285  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50         100     200      600        30    30e-9  45.0
17.5    26.5  4   190  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50        1000     100      600        30    30e-9  45.0
18.5    10.5  4   100  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50         100     100      600        30    30e-9  45.0
19.5     4.2  4   100  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50          10     100      600        30    50e-9  45.0
20.5     1.7  4   100  600     KL_v20 20200923_180000  forgettingFactorBin4v2SOUL 20220909_160320   3    4         1       0        1        16     12.6    50          10     100      600        30    50e-9  45.0

ESM Table: table_LUCIFER_TTM-AO.txt.20221116

# 0    1     2   3     4      5      6                 7                            8                9   10	   11       12       13        14      15      16      17           18       19         20     21    22   
Rmag   flux  bin freq  emGain base   rec               filtering                    pupils           tt  fw1_acq fw2_acq  fw1_obs  fw2_obs   TVbin   TVfreq  TVavg   TVflux   CL->freq     emG  GOpt->mode   amp  freq  
																							                          
-1.5 1.054E9  1   600    1     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    3         2       0        2         4      4.3     20     1250000     200        1         30    10e-9  80.0
0.0   2.65E8  1   600    1     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    3         2       0        2         4      4.3     20     1250000     200        1         30    10e-9  80.0
3.5  10.54E6  1   600    1     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    3         2       0        2         4      4.3     20       15000     200        1         30    10e-9  80.0
4.5   4.20E6  1   600    5     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         2       0        2         4      4.3     20       15000     200        5         30    10e-9  80.0
5.5   1.67E6  1   600   10     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         2       0        2         4      4.3     20        5000     200       10         30    10e-9  80.0
6.5   6.65E5  1   600   25     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         2       0        2         4      4.3     20        2000     200       25         30    10e-9  80.0
7.5   2.65E5  1   600  100     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         2       0        2         4      4.3     20         800     200       50         30    10e-9  80.0
8.5   1.05E5  1   600  300     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         2       0        2         4      4.3     20         800     200      100         30    10e-9  80.0
9.5   4.20E4  1   600  400     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         1       0        1         4      4.3     20         800     200      200         30    10e-9  80.0
10.5  1.67E4  1   400  400     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         1       0        1         4      4.3     20         800     200      200         30    10e-9  80.0
12.5    2648  1   400  400     KL_v20 20190406_035330  pureIntegratorSOUL           20181103_001410   3    4         1       0        1         4      4.3     20         800     200      200         30    10e-9  80.0
12.5    2648  2   400  600     KL_v20 20190407_034820  pureIntegratorSOUL           20220901_074516   3    4         1       0        1         4      4.3     20        1200     200      600         30    10e-9  80.0
13.0    1671  2   400  600     KL_v20 20190407_034820  pureIntegratorSOUL           20220901_074516   3    4         1       0        1        16     12.6     20         300     200      600         30    15e-9  80.0
14.0     665  2   400  600     KL_v20 20190407_034820  pureIntegratorSOUL           20220901_074516   3    4         1       0        1        16     12.6     20         300     200      600         30    15e-9  80.0
14.5     420  2   400  600     KL_v20 20190407_034820  pureIntegratorSOUL           20220901_074516   3    4         1       0        1        16     12.6     20         300     200      600         30    15e-9  80.0
14.5     420  4   400  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   3    4         1       2        1        16     12.6     50         600     200      600         30    20e-9  80.0
15.5     167  4   400  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   3    4         1       2        1        16     12.6     50         600     200      600         30    20e-9  80.0
16.5	  67  4   200  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   3    4         1       2        1        16     12.6     50         600     200      600         30    20e-9  80.0
17.5	26.5  4   200  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   3    4         1       2        1        16     12.6     50         600     200      600         30    20e-9  80.0
18.0	10.5  4   100  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   3    4         1       2        1        16     12.6     50         600     100      600         30    20e-9  80.0
20.5     1.7  4   100  600     KL_v20 20201013_212647  forgettingFactorBin4SOUL     20220909_160320   6    4         1       2        1        16     12.6     50         600     100      600         30    25e-9  80.0

Interaction Matrices and Reconstructors

[AOeng@sxadsec RECs]$ pwd
/local/aomeas/adsec_calib/M2C/KL_v20/RECs

Full AO

Bin 1

[AOeng@sxadsec RECs]$ more Rec_20190930_161000.fits

DATE    = '2018-12-15'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '1       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20181215_193646.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20181215_193646.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20181215_200941/' /                             
IM_MODES= '501.000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode2/20181103_001410' /

[AOeng@sxadsec RECs]$ more Rec_20191213_000000.fits 

DATE    = '2018-12-16'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'MODALREC'           /                                                
CT_MODES= '0       '           /                                                
COMMENT FITS (Flexible Image Transport System) format is defined in 'Astronomy  
COMMENT and Astrophysics', volume 376, page 359; bibcode 2001A&A...376..359H    
DATE    = '2018-12-16'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '1       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20181215_193646.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20181215_193646.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20181215_200941/' /                             
IM_MODES= '300.000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode2/20181103_001410' / 

Bin 2

[AOeng@sxadsec RECs]$ more Rec_20191011_125000.fits

DATE    = '2019-04-01'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '2       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20190401_195109.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20190401_195109.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20190401_210809/' /                             
IM_MODES= '250.000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode3/20181222_065045' /

Bin 3

[AOeng@sxadsec RECs]$ more Rec_20200922_150000.fits 

DATE    = '2020-02-25'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '3       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20200224_220350.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20200224_220350.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20200224_220741/' /                             
IM_MODES= '90.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode4/20200210_000000' /

[AOeng@sxadsec RECs]$ more Rec_20200922_153500.fits 

DATE    = '2020-02-25'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '3       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20200224_220350.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20200224_220350.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20200224_220741/' /                             
IM_MODES= '90.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode4/20200210_000000' / 

Bin 4

[AOeng@sxadsec RECs]$ more Rec_20200923_180000.fits

DATE    = '2020-09-17'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '4       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20200916_171331.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20200916_171331.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20200917_152304/' /                             
IM_MODES= '54.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode5/20200916_173857' /     

ESM

Bin 1

[AOeng@sxadsec RECs]$ more Rec_20190406_035330.fits 

DATE    = '2019-04-06'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '1       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20181215_193646.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20181215_193646.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20181215_200941/' /                             
IM_MODES= '12.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode2/20181103_001410' /   

Bin 2

[AOeng@sxadsec RECs]$ more Rec_20190407_034820.fits

DATE    = '2019-04-07'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '2       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20190401_195109.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20190401_195109.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20190401_210809/' /                             
IM_MODES= '12.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode3/20181222_065045' / 

Bin 4

[AOeng@sxadsec RECs]$ more Rec_20201013_212647.fits

DATE    = '2020-10-13'         / Creation UTC (CCCC-MM-DD) date of FITS header  
FILETYPE= 'intmat  '           /                                                
M2C     = 'KL_v20  '           /                                                
BINNING = '4       '           /                                                
M_DIST_F= 'M2C/KL_v20/disturb/ModalDisturb_20200916_171331.fits' /              
C_DIST_F= 'M2C/KL_v20/disturb/CmdDisturb_20200916_171331.fits' /                
IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20200917_152304/' /                             
IM_MODES= '13.0000 '           /                                                
SKIP_FRM= '2       '           /                                                
AVG_FRM = '2       '           /                                                
TT_REMV = '1       '           /                                                
PUPILS  = '/mode5/20200916_173857' /  

New AO Tables

Full AO: Bad Seeing

  • bin 1 300 modes (60% of 500)
    • Already built: Rec_20191213_000000.fits
  • bin 2 150 modes (60% of 250)
    • [AOeng@soul-sxwfs processConf]$ intmatAnalyseGui
    • IM_ACQ_D= 'M2C/KL_v20/intmatAcq/20190401_210809/'
    • full_bin2_Analyze.jpg:
      full_bin2_Analyze.jpg
    • ARGOS CalUnit Used???
      • HIERARCH cubestage.POSITION = '0.000 '
      • Did not click "This IM was acquired with the Argos calibration unit" on intmatAnalyze GUI
    • Rec_20221231_055939.fits
  • bin 3 54 modes (60% of 90)
    • intmat 20200224_220741
    • RR Used
      • HIERARCH cubestage.POSITION = '-98.000 '
    • Rec_20221231_062416.fits
  • bin 4 32 modes (60% of 54)
    • intmat 20200917_152304
    • ARGOS CalUnit Used
      • HIERARCH cubestage.POSITION = '0.000 '
      • Clicked "This IM was acquired with the Argos calibration unit" on intmatAnalyze GUI
    • Rec_20221231_061939.fits

autogain.conf changes

Bin 1, last of 4 loop rate parameter sets

07:15 Freq 750 -> 1000 Hz
bin1_f2_min        float  0.2
bin1_f2_start      float  0.2
bin1_f2_end_tt     float  15.0  -> 2.0
bin1_f2_end_ho1    float  6.0  -> 1.6
bin1_f2_end_ho2    float  2.0  -> 1.6
bin1_f2_step_tt    float  1.0  -> 0.2
bin1_f2_step_ho1   float  0.5  -> 0.1
bin1_f2_step_ho2   float  0.2  -> 0.1
bin1_f2_max_tt     float  16.0 -> 15.0
bin1_f2_max_ho1    float  6.0 -> 4.0
bin1_f2_max_ho2    float  6.0 -? 4.0
bin1_f2_max_iterations      int 5  -> 2
  • original gains
    • 072220
  • 63 seconds (end_tt = 2.0)
    • TN 073515
  • 66 seconds (end_tt = 3.0)
    • 073933

07:23 Freq 1000 - 1500 Hz
bin1_f1_max_tt     float  4.0 -> 15.0
bin1_f1_max_ho1    float  4.0
bin1_f1_max_ho2    float  4.0
  • 58 seconds

07:25 Freq 1500 - 2000 Hz
bin1_f0_max_tt     float  10.0 -> 15.0
bin1_f0_max_ho1    float  3.0 -> 4.0
bin1_f0_max_ho2    float  3.0  -> 4.0

07:28 Freq 400 - 750 Hz
bin1_f3_end_tt     float  3.0
bin1_f3_end_ho1    float  1.6
bin1_f3_end_ho2    float  1.0
bin1_f3_step_tt    float  0.3
bin1_f3_step_ho1   float  0.2
bin1_f3_step_ho2   float  0.2
bin1_f3_max_tt     float  12.0 -> 15.0
bin1_f3_max_ho1    float  12.0 -> 4.0
bin1_f3_max_ho2    float  12.0 -> 4.0
  • 55 seconds
    • 074631
  • 90 seconds (step_tt = 0.2)
    • 075657
  • 63 seconds (step_tt = 0.3)
    • 080001

07:48 Freq 1 - 400
bin1_f4_end_tt     float  4.0 -> 
bin1_f4_end_ho1    float  3.0
bin1_f4_end_ho2    float  2.0
bin1_f4_step_tt    float  0.5
bin1_f4_step_ho1   float  0.1
bin1_f4_step_ho2   float  0.1
bin1_f4_cycles     int    5
bin1_f4_nframes    int    50
bin1_f4_max_tt     float  15.0
bin1_f4_max_ho1    float  4.0
bin1_f4_max_ho2    float  4.0
bin1_f4_max_iterations      int 10 -> 2
  • not checked

Bin 2

08:15 Freq 1000 - 1500 Hz
  • 2:33
    • 081433
bin2_f1_factors    string "0.5 0.9 0.9 0.9 0.9 0.9"  tt = 0.8
bin2_f1_min        float  0.1 -> 0.2
bin2_f1_start      float  0.1 -> 0.2
bin2_f1_end_tt     float  4.0 -> 6.0
bin2_f1_end_ho1    float  0.8 -> 2.0
bin2_f1_end_ho2    float  0.8 -> 2.0
bin2_f1_step_tt    float  0.4 -> 0.75
bin2_f1_step_ho1   float  0.05 -> 0.3
bin2_f1_step_ho2   float  0.05 -> 0.3
bin2_f1_cycles     int    5
bin2_f1_nframes    int    50
bin2_f1_max_tt     float  8.0 -> 15.0
bin2_f1_max_ho1    float  2.0 -> 4.0
bin2_f1_max_ho2    float  2.0 -> 4.0
bin2_f1_ho_middle  int    50
bin2_f1_quadratic_tt        int    0
bin2_f1_refine_down_factor  float  0.5
bin2_f1_refine_up_factor    float  1.5
bin2_f1_max_iterations      int 2
  • 68 seconds tt_factor = 0.9
    • 082732
  • 47 second * 083129

08:31 Freq 750 - 1000 Hz
bin2_f2_factors    string "0.5 0.9 0.9 0.9 0.9 0.9"
bin2_f2_fmin       float  750.01
bin2_f2_fmax       float  1000
bin2_f2_min        float  0.2
bin2_f2_start      float  0.2
bin2_f2_end_tt     float  6.0
bin2_f2_end_ho1    float  2.0
bin2_f2_end_ho2    float  0.6 -> 2.0
bin2_f2_step_tt    float  0.8 -> 0.75
bin2_f2_step_ho1   float  0.1 -> 0.3
bin2_f2_step_ho2   float  0.1 -> 0.3
bin2_f2_cycles     int    5
bin2_f2_nframes    int    50
bin2_f2_max_tt     float  25.0 -> 15.0
bin2_f2_max_ho1    float  4.0 -> 4.0
bin2_f2_max_ho2    float  1.5 -> 4.0
bin2_f2_ho_middle  int    50
bin2_f2_quadratic_tt        int    0
bin2_f2_refine_down_factor  float  0.5
bin2_f2_refine_up_factor    float  1.5
bin2_f2_max_iterations      int 3 -> 2
  • 61 seconds
    • 084920
  • 67 seconds
    • 085400

08:58 Set bin2_f3 and bin2_f4 to same as bin2_f2

Bin 3

09:04 Freq 750 - 1000 Hz
bin3_f2_sequence   string "tt ho1 tt ho1"
bin3_f2_factors    string "0.7 0.9 0.8 0.9"
bin3_f2_fmin       float  750.01
bin3_f2_fmax       float  1000
bin3_f2_min        float  0.05 -> 0.2
bin3_f2_start      float  0.05 -> 0.2
bin3_f2_end_tt     float  5.1 -> 6.0
bin3_f2_end_ho1    float  1.6 -> 2.0
bin3_f2_step_tt    float  0.5 -> 0.75
bin3_f2_step_ho1   float  0.2 -> 0.3
bin3_f2_cycles     int    5
bin3_f2_nframes    int    50
bin3_f2_max_tt     float  15.0
bin3_f2_max_ho1    float  4.0
bin3_f2_ho_middle  int    90
bin3_f2_quadratic_tt        int    0
bin3_f2_refine_down_factor  float  0.5
bin3_f2_refine_up_factor    float  1.5
bin3_f2_max_iterations      int 2
  • 49 seconds (original)
    • 090652
  • 36 seconds (new)
  • 45 (add second ho1 scan)
    • 092403

09:26 Set bin3_f0 and bin3_f1 to bin3_f2 values

09:29 Freq 500 - 750 Hz
bin3_f3_sequence   string "tt ho1 tt" + ho1
bin3_f3_factors    string "0.7 0.9 0.8" + 0.9
bin3_f3_fmin       float  500.01
bin3_f3_fmax       float  750
bin3_f3_min        float  0.05
bin3_f3_start      float  0.05
bin3_f3_end_tt     float  5.1
bin3_f3_end_ho1    float  2.1
bin3_f3_step_tt    float  0.5
bin3_f3_step_ho1   float  0.2
bin3_f3_cycles     int    5
bin3_f3_nframes    int    50
bin3_f3_max_tt     float  7.1
bin3_f3_max_ho1    float  4.1
bin3_f3_ho_middle  int    90
bin3_f3_quadratic_tt        int    0
bin3_f3_refine_down_factor  float  0.5
bin3_f3_refine_up_factor    float  1.5
bin3_f3_max_iterations      int 3
  • 74 seconds (original)
    • 093352
  • 52 seconds (add ho1 second scan and change parameter)
    • 094804

09:53 Freq 1 - 500 Hz
  • 1:24 (with bin3_f3 parameters)
    • 095521
  • 38/35 seconds (5 -> 3 cycles, 50 -> 30 frames

Bin 4

10:05 Freq 1 - 500 Hz
bin4_f4_sequence   string "tt ho1 tt" + ho1
bin4_f4_factors    string "0.7 0.9 0.8" + 0.9
bin4_f4_fmin       float  1
bin4_f4_fmax       float  500
bin4_f4_min        float  0.05 -> 0.25
bin4_f4_start      float  0.05 -> 0.25
bin4_f4_end_tt     float  3.1 -> 1.0
bin4_f4_end_ho1    float  1.6 -> 2.0
bin4_f4_step_tt    float  0.1
bin4_f4_step_ho1   float  0.3
bin4_f4_cycles     int    5
bin4_f4_nframes    int    50
bin4_f4_max_tt     float  6.1
bin4_f4_max_ho1    float  2.0
bin4_f4_ho_middle  int    54
bin4_f4_quadratic_tt        int    1
bin4_f4_refine_down_factor  float  0.5
bin4_f4_refine_up_factor    float  1.5
bin4_f4_max_iterations      int 3 -> 2
  • 60 Seconds (original
    • 100907
  • 1:29 (Added ho1 second scan)
    • 101355
  • 33 seconds (5->3 cycles, 50->30 frames)
  • 40 seconds (30-> 50 frames)
  • 39 seconds (start with 0.3 gains
    • 102024
  • 72 seconds (0.25 to 1.0 on TT. Finding 0.22)
    • 110517

10:24 134 Hz

-- DougMiller - 31 Dec 2022
Topic revision: r6 - 01 Jan 2023, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback