[AOeng@sxadsec bm.20220517.shark-ncpa]$ pwd
/home/aoeng/scripts/tests/bm.20220517.shark-ncpa

  • [AOeng@sxadsec bm.20220517.shark-ncpa]$ python run-ncpa.py --modes 61 --coefficients 20e-9 --kl=KL_20
    NCPA not enabled. Enabling NCPA.
    set_z0, [0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,2e-08], KL="KL_20"
    Disabling NCPA.
    [AOeng@sxadsec bm.20220517.shark-ncpa]$ pwd
    /home/aoeng/scripts/tests/bm.20220517.shark-ncpa
    [AOeng@sxadsec bm.20220517.shark-ncpa]$ python run-ncpa.py --modes 61 --coefficients 10e-9 --kl=KL_20
    NCPA not enabled. Enabling NCPA.
    set_z0, [0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,1e-08], KL="KL_20"
    Disabling NCPA.
    [AOeng@sxadsec bm.20220517.shark-ncpa]$ python run-ncpa.py --modes 61 --coefficients 0e-9 --kl=KL_20
    NCPA not enabled. Enabling NCPA.
    set_z0, [0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0], KL="KL_20"
    Disabling NCPA.

  • [AOeng@sxadsec bm.20220517.shark-ncpa]$ python run-ncpa.py --modes 61 --coefficients 10e-9 --kl=KL_20
    NCPA not enabled. Enabling NCPA.
    set_z0, [0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,1e-08], KL="KL_20"
    Disabling NCPA.
    [AOeng@sxadsec bm.20220517.shark-ncpa]$ python run-ncpa.py --modes 61 --coefficients 20e-9 --kl=KL_20
    NCPA not enabled. Enabling NCPA.
    set_z0, [0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,2e-08], KL="KL_20"
    Disabling NCPA.

  • 214857
    61, 10, 215314
    Me to Everyone (2:57 PM)
    61, 20, 215659
    61, 20, 215659
    Me to Everyone (3:02 PM)
    61, 0, 220227
    61, 20, 220358
    61, 0, 220530
    61, 20, 220632
    Me to Everyone (3:08 PM)
    61, 0, 220832
    118, 20, 221119
    118, 0, 221317
    Me to Everyone (3:15 PM)
    118, 20, 221448
    118, 0, 221603
    118, 20, 221721
    118, 0, 221813