Details.

WFS power on

oCAM OK

Still work with the HBS.

Argos cal unit deployed.

12:00am

ask if chamber lights can be turned off.

12:12PM

chamber lights off.

Bin3

mag15

shutter 50

Wed Dec 14 19:26:30.129 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[246] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Wed Dec 14 19:26:30.145 2022 aos.info - WFS source set to: FLAOWFS

disturance 1000 and s1.5

Wed Dec 14 19:26:30.200 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

Setup Luci N30

Optimize:20221214_193055

ho1 skip frames.

OPTIMIZE:20221214_193255

HO1 SKIP FRAMES.

12:30pM

LOADED THE PREVIOUS PUPILS.

$ ln -sf table_LUCIFER_ACE-AO.txt.20221206 table_LUCIFER_ACE-AO.txt

The pupil 20220901_070135 was built from 20200210_000000 and the shift applied where x=0,y=-3

This pupils has a better looking at close loop during the pupil alignment.

optimize: 20221214_193439

gain ok

3.14,1.02,0.10

TN:20221214_194541

modal sr50

loop stable


build a pupil from the original one.

>>> makePupils.movePupils('20200210_000000',1,-3,240,4)

>>> makePupils.movePupils('20200210_000000',1,-3,240,4)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20221214_195740/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20221214_195740/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 148
out_of_pupil_slopes 2552
lines_to_add 11
residual_pixels_to_add 38
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20221214_195740
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode4/20221214_195740"
'20221214_195740'

New pupil to be tested.

build AO table witht he new pupil bin3

[AOeng@soul-sxwfs ao]$ ln -sf table_LUCIFER_ACE-AO.txt.20221214 table_LUCIFER_ACE-AO.txt

To be tested in close loop.

3:10PM

restart

check new pupil AO table.

Wed Dec 14 22:29:12.686 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

optimize gai:2022223014_223014

skip frame ho1

loop not stable with high order gains.

stop.03:32PM

-- JuanCarlosGuerra - 14 Dec 2022
Topic revision: r2 - 14 Dec 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.