Summary.

Details.

Some work with the HBS.

11:00am

powr on WFS.

12-13 18:20:34.422798| MAIN > Exception: Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR
WfsArbitrator_26141|ERR| 60|2022-12-13 18:20:34.422902| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

Power on again.

bcu47 temp -3.5C

  • Ocam
  • One bad quadrnt.
  • change bin from wfs control gui
  • triggered the triangel feature.
  • power cycle bcu2k
  • ok
ARGOS SWING ARM CONTROLLER DISCONNECTED.
  • PROCESS UP.
  • RESTART THE PROCESS FROM SX-LALAS
  • IT HAS TO BE CHECKED IN THE CABINET.
  • the oss shows argos null status.
  • ping controller SX. 192.168.26.32
  • not reacheable.
  • Sent the instructions to Pat for checking the o=power of the cabinet.
02:00PM

There is a work ongoing with the HBS that it doen't allow to tip the telescope.At the moments no checks for the Argos swing arm electronic in the CRextension

SoulSx checks in StandBy.

No time for soulSX close loop checks.

Argos swing arm recovered. The controllwer was in stalled state. Reboot locally and it back to work.

Reset the controller from the Argos interface to reset the error and load the configuration parameters.

-- JuanCarlosGuerra - 13 Dec 2022
Topic revision: r3 - 14 Dec 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.