Details.

* the optimize gain has to be changed from RR to argos.

File:autogain.conf

change: from 0 to 1

# Argos source
# If set, prevent gains from being modified by the RR_enabled flag

argos_source int 1

08:30 am

Briefing.

Points for today.

-parallel test of SX-Luci close loop with the Argos cal unit

-DX power on debug in the time that the telescope is still in use.

-Bin1 performances.

-Bin3 calibrations.

09:00am
  • LN is pumping. Telescope in use. chamber lights on
  • PepsiPol configured.
Soul-DX power on/off debug and test.

10:39am

Telescope configured for Luis both sides.

Telescope released.

10:41AM

Deploy Argos Cal units for both sides.

Right side the OSS doen't work. The click. The Argos interface takes about 1 minute to see the command executed.

Right side Hexapod positions:
  • -2.55,-1.6,1.45,-150,-200
10:52am

Stop the DX power on sequence debug. Revert to default configurations for Argos Cal unit work.

OCAM.
  • Ok
CCD47 not live.
  • Rebinning
  • OK
11:00AM

SX argos cal unit deployment.

DX close loop

AO table:

5.5 1.67E6 1 1700 64 KL_v29 20221203_000001 iir1700HzV001 20200131_180431 3 4 2 0 2 4 4.3 20 5000 200 6 30 5e-9 80.0
6.5 6.65E5 1 1700 163 KL_v29 20221203_000001 iir1700HzV001 20200131_180431 3 4 2 0 2 4 4.3 20 2000 200 12 30 5e-9 80.0
  • mag10
  • Optimize not disturbance: 20221006_181920
  • Gain vector: 1.45,0.13,0.31
  • gopton
  • TN:20221206_182125,_182250
Stable.

Close loop

The disturbance name doens't reflect the built KL. The daytime.conf files are:

disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1700.00_sd3892.fits"
disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1700.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq1700.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1700.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1700.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1200.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1200.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq900.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq900.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq750.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq200.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.00_sd3892.fits"
#disturbToAdd string "/local/aomeas/adsec_calib/M2C/KL_v29/atm_disturb/dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1700.00_sd3892.fits"

  • mag10
  • Tue Dec 6 18:26:55.522 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

loaded disturbance.

AdSecArbitrator _34405|WAR| 6190|2022-12-06 18:29:56.407220| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
Last message repeated
AdSecArbitrator_34405|INF| 6191|2022-12-06 18:29:56.407574| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator_34405|WAR| 6192|2022-12-06 18:29:56.407599| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters

edit the daytime table for the Argos disturbance. Previously loaded the RR

CCD47.

Optimize: 20221206_183507

Gain:1.8,0.37,0.45