20221203_DX_Day DX S-LUCI Comm

drwxrwxr-x. 4 AOeng AOeng 4096 Nov 25 16:52 sx-tables/ -rw-rw-r--. 1 AOeng AOeng 7711 Nov 25 16:52 table_LUCIFER_ACE-AO_20200206_01.txt -rw-rw-r--. 1 AOeng AOeng 7711 Dec 3 17:24 table_LUCIFER_ACE-AO_20221203_01.txt lrwxrwxrwx. 1 AOeng AOeng 36 Dec 3 17:28 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO_20221203_01.txt

10:50 PresetAO from Command GUI
  • Enrico updated AO table for new bin1 Rec
  • Use forgettingFactorSOUL
  • Close loop ok
  • 0.8 seeing
  • Optimize gain not work because gains are too high for forgettingFactorSOUL
  • Guido make new Rec with IIF filter information
  • 20221203_000001.firts

11:10 PresetAO
  • Optimize Gain factor of 2 too high
  • Fabio set Argos_Source = 0 in autogain.conf
  • This will think RR is used so scale optimize gain parameters down by 2

11:20 Click Optimize Gain button
  • GOPT on, 0.93
  • gains 0.95, 0.24, 0.35
  • Tn 182430, 182523, 182556

11:30 set daytime.conf to 1.5" seeing
  • 1.5" seeing
  • gain 0.94, 0.28, 0.36
  • TN 183559, 183620, 183637

11:40 2.0" seeing
  • Optimize Gain: OK but saw a "line" across pupils for first scan of HO2
  • tN 184700, 184734, 184750
  • soul-dxwfs /home disk full
    • Fabio remove a bunch of WFS Masterdiagnositics files from daytime work

11:57 2.0" seeing again
  • TN 190200, 190223, 190238

Bin 2 Reconstructor Measurement

12:25 Looking bin2 pupils
  • LUCI1 pupils 20190606_074345
  • Shift x+2, y-2 pupils 20200205_211349

12:31 Close loop bin1 to get a good flat for bin2
  • un-click restore last shape so good flat is there for bin 2

12:42 Bin 2 Open Loop collection
  • JC build a disturbance with intmatDisturb GUI
  • 20221203_194102
  • Open Bin1 loop, change OCAM binning (200 Hz, 10 l/D, EM 3)
  • OL 20221203_194919 (reflatten after 1st tieration. not useful)
  • Remove acq1 and acq2 in
    • /local/aomeas/adsec_calib/M2C/KL_v29/intmatAcq/20221203_194919
  • Rec 20221203_195514 (70 modes OL)
  • CL test, TT is bad, drive hex away

1:08 Bin 2 OL again
  • Close loop with new bin 2 Rec but only apply HO1. Good Flat
  • Open loop
  • Collect 1 iter in OL
  • IM 20221203_200743

12:59 Bin 2 Closed loop
  • Close loop with new bin 2 Rec but only apply HO1. Good Flat
  • Fabio change intmatAcquire proceedure to no apply default.sav
  • Doug started the GUI too soon. Data collected with dafault.sav Not useful
    • 20221203_201611
  • Re-start GUI

1:23 Bin 2 Open Loop
  • JC make a new disturbance file 20221203_202148
  • SOU_Optim_03_time2.fits
  • intmatAcquire OL, 5 iter
  • IM 20221203_202254
  • Rec 20221203_202829 (tt looks better)
  • CL test
  • OK gain 0.3, 0.05, 0.05

01:37 Bin 2 Closed loop
  • IM 20221203_203620
  • Rec 20221203_203840

01:50 Bin 2 CL with 3.0 l/D
  • IM 2021203_205042
  • Rec 20221203_205314
  • Check

-- DougMiller - 03 Dec 2022
Topic revision: r3 - 03 Dec 2022, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback