20221130 DX S-LUCI Comm

Hexapod postions:
  • Power on WFS
  • OCAM
  • OK
PreasetAO

Error:
WfsArbitrator _66437|ERR| 226|2022-11-30 16:18:05.768813| MAIN > Controller in wrong state for requested operation. (-11005) CTRL_WRONG_STATE_ERROR

Close loop with REC for 20/D: Rec_20221129_210253.

stable with hgh order gains applied.

Change 10l/D

09:30 stable some dots at the edge but increasing the TT clear some edge effects...
  • save a flat
  • 20221130_0930_10l.D.sav
  • TN 163340
  • Yesteraday's last REC
  • 10 l/D
  • Hex -3.1 -1.6 1.5 -153 -266

09:35 6 l/D
  • TN 163512

04:37 3 l/D
  • TN 163719
  • Gain 0.3, 0.05, 0.05

04:42 Measure Rec with 3 l/D
  • dist KL-v29 20220607_184919
  • 200 Hz, 3 l/D
  • 3 iter
  • CL
  • L_v29 20221129_210253
  • Gain 0.3, 0.05, 0.05
  • IM 164535

04:58 Measure Rec with 3 l/D
  • dist KL-v29 20220607_184919
  • 200 Hz, 3 l/D
  • 9 iter
  • CL
  • KL_v29 20221129_210253
  • Gain 0.3, 0.05, 0.05
  • IM _165817
  • Analyse
Enrico realised that the disturbance done for the RR. the dist should be multiply*2

Generate the new disturbance from the used one for the ArgosCalUnit.

10:11 am

generate from IDL a new gain for Argos:intmatDistGui
  • SOUL-optim03_times2.fits
  • KL_29
  • KL:649.
  • pushpull
  • cycle:1
  • frames:3
Dist file: CmdDisturb_20221130_171620.fits

Generate Inmat.

KL_29

dist:_171620

9 iter

cl

Rec:_210253

Gain:0.3,0.05,0.05

Acquire:

shows an error in the IDL.

AdSecArbitrator _120577|INF| 3034|2022-11-30 17:19:20.228440| MAIN > Compare: 0
AdSecArbitrator _120577|INF| 3035|2022-11-30 17:19:20.228460| MAIN > Tag: /local/aomeas/adsec_calib/M2C/KL_v29/intmatAcq/20221130_171919/CmdDisturb_20221130_171620_acq0.fits
AdSecArbitrator _120577|INF| 3036|2022-11-30 17:19:20.228486| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|INF| 3039|2022-11-30 17:19:20.228528| COMMANDHANDLER > FSM (status: AOSet) has received command 2019 (Set disturb)
Last message repeated
AdSecArbitrator _120577|INF| 3040|2022-11-30 17:19:20.228543| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|WAR| 3044|2022-11-30 17:19:20.356113| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
Last message repeated
20223011 17:19:20.3568 Alert: Warning: setDisturb not executed (retry)
AdSecArbitrator _120577|INF| 3045|2022-11-30 17:19:20.356524| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3046|2022-11-30 17:19:20.356565| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:19:38.6505 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator _120577|INF| 3034|2022-11-30 17:19:20.228440| MAIN > Compare: 0
AdSecArbitrator _120577|INF| 3035|2022-11-30 17:19:20.228460| MAIN > Tag: /local/aomeas/adsec_calib/M2C/KL_v29/intmatAcq/20221130_171919/CmdDisturb_20221130_171620_acq0.fits
AdSecArbitrator _120577|INF| 3036|2022-11-30 17:19:20.228486| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|INF| 3039|2022-11-30 17:19:20.228528| COMMANDHANDLER > FSM (status: AOSet) has received command 2019 (Set disturb)
Last message repeated
AdSecArbitrator _120577|INF| 3040|2022-11-30 17:19:20.228543| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|WAR| 3044|2022-11-30 17:19:20.356113| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
Last message repeated
20223011 17:19:20.3568 Alert: Warning: setDisturb not executed (retry)
AdSecArbitrator _120577|INF| 3045|2022-11-30 17:19:20.356524| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3046|2022-11-30 17:19:20.356565| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:19:38.6505 Alert: HighOrderOffload: HighOrderOffload vector ready
Probably the HO modes were too high.

comparing the two disturbance files.

threshold 1.4 amp for the x2 disturbance.

new disturbance renme the previous one.

Generate the disturbances:

_172655

Acquire IntMat.
  • IDL error
*

20223011 17:28:40.2787 Alert: Warning: setDisturb not executed (retry)
AdSecArbitrator _120577|INF| 3073|2022-11-30 17:28:40.278239| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3074|2022-11-30 17:28:40.278286| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:28:40.4211 Alert: HighOrderOffload: HighOrderOffload vector ready

*

20223011 17:28:40.2787 Alert: Warning: setDisturb not executed (retry)
AdSecArbitrator _120577|INF| 3073|2022-11-30 17:28:40.278239| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3074|2022-11-30 17:28:40.278286| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:28:40.4211 Alert: HighOrderOffload: HighOrderOffload vector ready

10:29am

Going to IDL to cut to 1.

saved in the same file

Generate disturbance.

_173044

Acquire

IDL error same one.


AdSecArbitrator _120577|INF| 3087|2022-11-30 17:31:17.574582| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3088|2022-11-30 17:31:17.574614| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:31:17.5755 Alert: Warning: setDisturb not executed (retry)

AdSecArbitrator _120577|INF| 3087|2022-11-30 17:31:17.574582| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3088|2022-11-30 17:31:17.574614| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:31:17.5755 Alert: Warning: setDisturb not executed (retry)
10:35 am

discussion about this topic.

Generate dist.

same file but 600 modes.

_173734

Acquire:

IDL error:

AdSecArbitrator _120577|INF| 3096|2022-11-30 17:38:03.502142| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|WAR| 3100|2022-11-30 17:38:03.648384| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
Last message repeated
AdSecArbitrator _120577|INF| 3101|2022-11-30 17:38:03.648675| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3102|2022-11-30 17:38:03.648713| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:38:03.64
AdSecArbitrator _120577|INF| 3096|2022-11-30 17:38:03.502142| SERIALIZATION > > disturbActive: ON
AdSecArbitrator _120577|WAR| 3100|2022-11-30 17:38:03.648384| IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
Last message repeated
AdSecArbitrator _120577|INF| 3101|2022-11-30 17:38:03.648675| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3102|2022-11-30 17:38:03.648713| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters
20223011 17:38:03.64
Checking for an IntMat generated yesterday and there is not files in KL_29 for yesterday (20221129)
  • closing the gui open the files were there after another intmatgui opened from Doug terminal...
  • Try last today dist
  • same idl error.
Load a dist from yesterday and the file is loaded in the Adsec

10:47am

Acquire InMat.
  • dist:20221129_202600
  • iter=1
  • kl_29
  • rec:20221129_210253
  • gain vect: 0.3,0.05,0.05
Outputfile:

10:54am

generate the intmat from a file: generate the intmat from a file: doug_0_6.3_7_20.2.fits

Acquire:

OK

generated:

_175517

Generate soul_optim_03.fits

_175624

Inmatacq acquire

test with the gain zero

cmd dist loaded in the adsec.
  • OK
  • Rec output: _180124
  • Not used. Test file
11:03am

IDL load file, trim to 0.7

SOUL_optim_03_times2.fits

Generate dist:
  • _180124
Acquire
  • same idl error
*

Last message repeated
AdSecArbitrator _120577|INF| 3271|2022-11-30 18:05:31.120109| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3272|2022-11-30 18:05:31.120152| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters

*

Last message repeated
AdSecArbitrator _120577|INF| 3271|2022-11-30 18:05:31.120109| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
AdSecArbitrator _120577|WAR| 3272|2022-11-30 18:05:31.120152| MAIN > LoadDisturbTag: WARNING - IDL Invalid/Uncoherent input parameters

Loaded the dist

  • error in Adsec, disturbance already running
SecArbitrator _120577|WAR| 3315|2022-11-30 18:09:48.146745| IDL > Command returns retryable error : IDL The disturbance triggered by SC is still running
Last message repeated
AdSecArbitrator _120577|INF| 3316|2022-11-30 18:09:48.146999| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL The disturbance triggered by SC is still running)
AdSecArbitrator _120577|WAR| 3317|2022-11-30 18:09:48.147024| MAIN > LoadDisturbTag: WARNING - IDL The disturbance triggered by SC is still running
SecArbitrator _120577|WAR| 3315|2022-11-30 18:09:48.146745| IDL > Command returns retryable error : IDL The disturbance triggered by SC is still running
Last message repeated
AdSecArbitrator _120577|INF| 3316|2022-11-30 18:09:48.146999| COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL The disturbance triggered by SC is still running)
AdSecArbitrator _120577|WAR| 3317|2022-11-30 18:09:48.147024| MAIN > LoadDisturbTag: WARNING - IDL The disturbance triggered by SC is still running
* SOLUTION:

Trim 0.5

Generate disturbance
  • amplitude:SOUL_optim_03_times2
  • output: 20221130_180743
Loaded dist Loaded dist * OK IntmatAcquire:
  • KL_v29
  • 20221130_180743
  • ite=9
  • Rec KL_29
  • 20221129_210253
  • Gains to 0
  • Close loop
  • Rec output :20221130_181015. Tests.

11:20am

IntmatAcqure.
  • KL_v29
  • 20221130_180743
  • iter=9
  • Rec KL_29
  • 20221129_210253
  • Gains to 0.3,0.05,0.05
  • Close loop
  • output: 20221130_181124
Mirror GUI

Act468 81um
  • iteration 7 showed a bite in the top mirror.
Analyse
  • 20221130_181914
  • skip=2
  • avg frame=2
  • remove TT
  • IM with Argos
Reconstructor + combine signal file
  • there were some modes not well corrected, due to the jump in one of the iterations
  • going with the 600 modes rec.
  • cut svd 1
  • Reconstructor modes.
  • Some effect in the reconstructor modes.
  • The rec is good or check pupils. (elab)
  • output:20221130_182745
11:38am

analyse the Rec for pupil verification using the elab.

IDL calls:

>check_pupil_im,'20221130_163340','adsec_calib/M2C/KL_29/RECs/Intmat_20221130_182745.fits','DX/SX'

'<TN using the current REC>',<Rec_Intmat to be analyse>','<sideSX/DX'>

debugging an issue with the intalation of the pro in the LBTO elab machines. debugging an issue with the intalation of the pro in the LBTO elab machines. working:
  • Subapertures bellow 0.5 of norm RMS=2
  • not too many
  • from Enrico comments ~10 subap should be a good number.
11:50am

Continuing to have a new rec with 500 modes for close loop check

Acquire a new IntMat
  • KL_v29
  • 20221130_180743
  • iter=9
  • Rec KL_29
  • 20221129_210253
  • Gains to 0.3,0.05,0.05
  • Close loop
  • Output:20221130_181914
12:30PM

Build Rec with 500 modes.

Rec:20221130_192802 Rec:20 some effects in the low order modes.

Test the Rec in CL

TN:20221130_193729,_193954

Loop stable with the ho1 0.05 and ho2=0.05

12:42PM

Check atmos dist

mag 10.8.

dist kl_29 (search for the right directory)

atmopss1.5

close loop

optimize

Optimize:2022130_194523

TT tilt low due to ooure integrator.

TN:20221130_194817,_194837

12:50PM
  • loaded atmos s2.0
  • optimize:20221130_195044
  • Tn:_195224,_195259,_195317,_195408

13:05 Fabio and Doug working on getting a good pupil position - Fabio inverted the signs and the axes - there is still issue of the Bite and the TT (tip-tilt)

13:08 doing Analyse Intmat again - 20221129_194403

13:13 Since lower-orders are propagating more noise than signals, we will change the gains on the TT and re-do it.

created a new amplitude file from 672_0.7.fits (from disturb file: 20220601_183726) : doug_0_6.3_7_20.2.fits

DISTURBOIM 20221129_ 202600
Modal basis = KL_v29
type = Push-pull
Frames per mov = 3
Cycle = 1
#Modes = 600
Amp = doug_0_6.3_7_20.2.fits

13:23 WIll acquire new IM

Intmatacq 20221129_203017
Pup = 20200131_180431
Dist = 20221129_ 202600
Modulation = 20 l/D
Iteration = 1
Loop speed = 200 Hz
bin = 1
EMGain = 600
Rec.Close loop = open loop
Gain vector close loop =

Rec 20221129_203531
Modal Basis: KL_v29
intmatacq = 20221129_203017
n modes = 350
TT removal = OFF
cutted = 1
Note:13:45 Closing the loop - we have a skip-frame,

Intmatacq 20221129_204522
Pup = 20200131_180431
Dist = 20221129_ 202600
Modulation = 20 l/D
Iteration = 1
Loop speed = 200 Hz
bin = 2
EMGain = 600
Rec.Close loop = 20221129_203531
Gain vector close loop =

Rec 20221129_204806
Modal Basis: KL_v29
intmatacq = 20221129_204522
n modes = 350
TT removal = OFF
cutted = 1
Note:

TN 205317 - with H01

205425 - with H01, H02

Intmatacq 20221129_210039
Pup = 20200131_180431
Dist = 20221129_ 202600
Modulation = 20 l/D
Iteration = 2
Loop speed = 200 Hz
bin = 1
EMGain = 600
Rec.Close loop = 20221129_204806
Gain vector close loop = 0.1 0.1 0.0

Rec 20221129_210253
Modal Basis: KL_v29
intmatacq = 20221129_210039
n modes = 500
TT removal = OFF
cutted = 1
Note:

TN:_ 210821 - 0.05 0.05 0.05 - 500 modes

DONE FOR TODAY.

Bin 3 pupil mask test

...had issues, but now have a bin3 pupil ready for IM/REc measurement the ARGOS CalUnit

-- JuanCarlosGuerra - 30 Nov 2022
Topic revision: r5 - 02 Dec 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback