20221129_DX_Day. DX S-LUCI Comm

04:25 Starting up DX WFS

04:30 Fabio check that WFS internal source works. Yes!

05:11 Find source on CCD47
  • Start with Greg and Juan Carlos' numbers from yesterday
  • Found, coma corrected, focused
  • M2 -3.016, -1.6, 1.47, -155, -268
  • M3 -160, 70, 0, -25.725 (LUCI2 on-sky values)
  • Bayside -77, -50, 54.8
  • Found on OCAM: NOTE, had to set OCAM parameters because EMG=1 by default
    • Did not have to move anything so values above are reasonable
  • 10.5 mag on OCAM, less than the 9.2 expected
  • ocam_start.jpg:
    ocam_start.jpg

05:46 Start looking at pupils
  • Manually put pupils on cloop Pupils
  • about Y=40, X=-54
  • AO Table: table_LUCIFER_ACE-AO_20200205_01.txt
  • Pupil 20200131_180431
  • Rec 20200205_194503
  • Filter forgettingFactorSOUL
  • Load Rec
    20222911 17:57:54.4295 Alert: HighOrderOffload: HighOrderOffload vector ready
    AdSecArbitrator_120577|INF|       722|2022-11-29 17:58:13.017523|            MAIN > Received cmd: LoadRecMatTag("KL_v27", "20200205_194503", "forgettingFactorSOUL", 0)
    AdSecArbitrator_120577|INF|       723|2022-11-29 17:58:13.017610|  COMMANDHANDLER > FSM (status: AOSet) has received command 2022 (SetRecMat)
    idl_120473         |INF|      1659|2022-11-29 17:58:13.018515|             MAIN > Loading: /local/aomeas/adsec_calib/M2C/KL_v27/RECs/Rec_20200205_194503.fits
    idl_120473         |INF|      1660|2022-11-29 17:58:13.164642|             MAIN > the given M2C is not compatible with the current AdSec configuration
    idl_120473         |INF|      1661|2022-11-29 17:58:13.164703|             MAIN > IDL Invalid/Uncoherent input parameters
    20222911 17:58:13.1661 Alert: Warning: setRecMat not executed (retry)
    AdSecArbitrator_120577|WAR|       724|2022-11-29 17:58:13.164993|             IDL > Command returns retryable error : IDL Invalid/Uncoherent input parameters
    AdSecArbitrator_120577|INF|       725|2022-11-29 17:58:13.165134|  COMMANDHANDLER > Command not executed (status RETRY) (errstr IDL Invalid/Uncoherent input parameters)
    AdSecArbitrator_120577|WAR|       726|2022-11-29 17:58:13.165167|            MAIN > LoadRecMatTag: WARNING - IDL Invalid/Uncoherent input parameters
    20222911 17:58:14.6632 Alert: HighOrderOffload: HighOrderOffload vector ready
    20222911 17:58:34.7182 Alert: HighOrderOffload: HighOrderOffload vector ready
    

06:16 Start IM collect from scratch
  • dist: 20220531_154707 (built for LBTI)
  • Popup error (error closing loop) even though we did not click Acquire in closed Loop

06:20 No focal station set
  • Set to RFBG
    AdSecArbitrator_120577|INF|       761|2022-11-29 18:21:21.270462|            MAIN > Received cmd: SelectFocalStation(bentGregorianFront)
    AdSecArbitrator_120577|INF|       762|2022-11-29 18:21:21.270520|  COMMANDHANDLER > FSM (status: AOSet) has received command 2033 (Set focal station)
    AdSecArbitrator_120577|INF|       763|2022-11-29 18:21:21.270561|   CONFIG-LOADER > Getting configuration file '/home/aoeng/live/aoroot/conf/adsec/current/processConf/fiberswitch.conf'
    AdSecArbitrator_120577|INF|       764|2022-11-29 18:21:21.270678|   CONFIG-LOADER > 9 parameters read from config file
    AdSecArbitrator_120577|INF|       765|2022-11-29 18:21:21.270689|   CONFIG-LOADER >  - HOST: 192.168.18.91
    AdSecArbitrator_120577|INF|       766|2022-11-29 18:21:21.270695|   CONFIG-LOADER >  - LogLevel: DEB
    AdSecArbitrator_120577|INF|       767|2022-11-29 18:21:21.270702|   CONFIG-LOADER >  - PORT: 10001
    AdSecArbitrator_120577|INF|       768|2022-11-29 18:21:21.270708|   CONFIG-LOADER >  - Simulation: 0
    AdSecArbitrator_120577|INF|       769|2022-11-29 18:21:21.270715|   CONFIG-LOADER >  - TIMEOUT_TCP_MS: 1000
    AdSecArbitrator_120577|INF|       770|2022-11-29 18:21:21.270721|   CONFIG-LOADER >  - TIME_READ_MS: 3500
    AdSecArbitrator_120577|INF|       771|2022-11-29 18:21:21.270727|   CONFIG-LOADER >  - WAIT_TIME_S: 3
    AdSecArbitrator_120577|INF|       772|2022-11-29 18:21:21.270733|   CONFIG-LOADER >  - channel1: 2
    AdSecArbitrator_120577|INF|       773|2022-11-29 18:21:21.270740|   CONFIG-LOADER >  - channel2: 4
    AdSecArbitrator_120577|DEB|       774|2022-11-29 18:21:21.270755|     FiberSwitch > Creating FiberSwitch...
    AdSecArbitrator_120577|DEB|       775|2022-11-29 18:21:21.270764|     FiberSwitch > Creating TCP connection...
    20222911 18:21:25.3037 Alert: HighOrderOffload: HighOrderOffload vector ready
    20222911 18:21:45.2308 Alert: HighOrderOffload: HighOrderOffload vector ready
    20222911 18:22:05.2979 Alert: HighOrderOffload: HighOrderOffload vector ready
    AdSecArbitrator_120577|ERR|       776|2022-11-29 18:22:24.270400|   TCPCONNECTION > TcpConnection creation failed
    20222911 18:22:25.2711 Alert: HighOrderOffload: HighOrderOffload vector ready
    AdSecArbitrator_120577|DEB|       777|2022-11-29 18:22:27.270599|     FiberSwitch > Creating TCP connection...
    
  • Set to BentARGOS successful
  • Set to frontBentGregorian successful
  • InmatAcquire still fail with OCAM not live
  • Set FASTLINK.ENABLE in variable inspector and still the Mirror GUI does not

07:20 intmatAcquire
  • Open Loop
  • 1 iteration
  • 4000 frames
  • 6 l/D
  • 20220531_154707 disturance
    • 20221129_191947

07:22 intmatAnalyse
  • Rec 192303 (350 OL modes)
  • closed loop shows missing edge at 2:0

07:45 flat default_20220606)300m.sav
  • 20220601_183726
  • Open Loop
  • data saved 20221129_194403
  • intmatAnalyse
  • 20221129_194634.fits
  • Tip/Tilt had no signal so closed loop ran away

08:13 New modegain file
  • doug_3_6.3_7_20.2.fits
  • intmatDisturbGUI
  • KL_v29, 600 modes, frames 3, push-pull=1, doug_0_6.3_7_20.2.fits, 3700 length
  • 20221129_202125

08:23 intmatAquire
Written M2C/KL_v29/disturb/ModalDisturb_20221129_202600.fits
% READFITS: Now reading 672 by 672 array
Written M2C/KL_v29/disturb/CmdDisturb_20221129_202600.fits

08:31 intmatAquire
  • 20221129_203017

08:31 intmatAnalyze
  • 20221129_203531

08:40 Acquire
  • Closed loop
  • gain0.1_10modi.fits
  • 20221129_204522

08:47 Analyze
  • 204806

08:53 Closed Loop
  • TN ho1 only 205317
  • TN ho1, ho2 205425

09:01 Acquire Closed Loop Rec above
  • Gain 0.0, 0.1, 0.0
  • data 20221129_210039

09:03 Analyze
  • 20221129_210253

09:08 Closed Loop
  • gain 0.05, 0.05, 0.05
  • TN 210821, 211034

09:12 No RetroReflector tomorrow. Change l/D, check pupil

-- DougMiller - 29 Nov 2022