Summary.

Power on WFS.

Check functionality.

found an error in the wfsarbitrator. Message sent to Fabio et al. Investigation will happen with the Arcetri team in town.

Details.

Stop process and start.

Arbitrator not connected.

Error message of the wfsarb process:

WfsArbitrator _33521|INF| 38|2022-11-23 17:41:33.945619| MAIN > read Encoder correction matrix file is OK
WfsArbitrator _33521|FAT| 39|2022-11-23 17:41:33.945630| MAIN > Some problem occurred (i.e. MsgD offline): AOApp not started (run not executed)

w_start_all

terminal error:

Traceback (most recent call last):
File "/home/AOeng/live/aoroot/bin/w_start", line 256, in <module>
if name == '__main__': main()
File "/home/AOeng/live/aoroot/bin/w_start", line 144, in main
processControl.waitProcessStart( app, process)
File "/home/AOeng/live/aoroot/lib/python/AdOpt/processControl.py", line 243, in waitProcessStart
raise AdOptError ( AOErrCode ['TIMEOUT_ERROR'], "Timeout error waiting for process %s start" % process)
AdOpt.AOExcept.AdOptError: Timeout error waiting for process housekeeperWFS start - TIMEOUT_ERROR

WfsArbitrator _43284|INF| 40|2022-11-23 17:54:09.536674| MAIN > Communication with MsgD stopped
WfsArbitrator_46405|INF| 1|2022-11-23 18:02:49.043799| MAIN > Creating arbitrator... serialize method: TEXT
WfsArbitrator _46405|ERR| 2|2022-11-23 18:02:49.043846| MAIN > Required keyword GoptStabilityThresholdBin1 missing from configuration file
WfsArbitrator _46405|ERR| 3|2022-11-23 18:02:49.043865| MAIN > Required keyword GoptStabilityThresholdBin2 missing from configuration file
WfsArbitrator _46405|ERR| 4|2022-11-23 18:02:49.043880| MAIN > Required keyword GoptStabilityThresholdBin3 missing from configuration file
WfsArbitrator _46405|ERR| 5|2022-11-23 18:02:49.043888| MAIN > Required keyword GoptStabilityThresholdBin4 missing from configuration file
WfsArbitrator_46405|WAR| 6|2022-11-23 18:02:49.043911| MAIN > Logger MASTDIAGN not configured in config file (key MASTDIAGNLogLev). Using default level (INF).
WfsArbitrator_46405|WAR| 7|2022-11-23 18:02:49.043931| MAIN > Logger ADSEC not configured in config file (key ADSECLogLev). Using default level (INF).
WfsArbitrator_46405|WAR| 8|2022-11-23 18:02:49.043946| MAIN > Logger OPTLOOPDIAG not configured in config file (key OPTLOOPDIAGLogLev). Using default level (INF).
WfsArbitrator_46405|INF| 9|2022-11-23 18:02:49.043983| MAIN > WfsArbitrator starting from state AOPrepared (from configuration file)
WfsArbitrator_46405|WAR| 10|2022-11-23 18:02:49.044014| MAIN > clGainX keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|WAR| 11|2022-11-23 18:02:49.044032| MAIN > clGainY keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|INF| 12|2022-11-23 18:02:49.044042| MAIN > Set clGainX for bin 1 to 0.700000
WfsArbitrator_46405|INF| 13|2022-11-23 18:02:49.044048| MAIN > Set clGainY for bin 1 to 0.000000
WfsArbitrator_46405|WAR| 14|2022-11-23 18:02:49.044067| MAIN > clGainX keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|WAR| 15|2022-11-23 18:02:49.044084| MAIN > clGainY keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|INF| 16|2022-11-23 18:02:49.044093| MAIN > Set clGainX for bin 2 to 0.700000
WfsArbitrator_46405|INF| 17|2022-11-23 18:02:49.044100| MAIN > Set clGainY for bin 2 to 0.000000
WfsArbitrator_46405|WAR| 18|2022-11-23 18:02:49.044117| MAIN > clGainX keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|WAR| 19|2022-11-23 18:02:49.044133| MAIN > clGainY keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|INF| 20|2022-11-23 18:02:49.044141| MAIN > Set clGainX for bin 3 to 0.700000
WfsArbitrator_46405|INF| 21|2022-11-23 18:02:49.044148| MAIN > Set clGainY for bin 3 to 0.000000
WfsArbitrator_46405|WAR| 22|2022-11-23 18:02:49.044163| MAIN > clGainX keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|WAR| 23|2022-11-23 18:02:49.044179| MAIN > clGainY keyword not defined in config file. Using default value of 0.7
WfsArbitrator_46405|INF| 24|2022-11-23 18:02:49.044187| MAIN > Set clGainX for bin 4 to 0.700000
WfsArbitrator_46405|INF| 25|2022-11-23 18:02:49.044194| MAIN > Set clGainY for bin 4 to 0.000000
WfsArbitrator_46405|INF| 26|2022-11-23 18:02:49.044209| MAIN > RotatorSign keyword not defined in config file. Using default sign=-1
WfsArbitrator_46405|INF| 27|2022-11-23 18:02:49.044219| MAIN > Set coordinate system rotation: 0.0 degrees
WfsArbitrator_46405|INF| 28|2022-11-23 18:02:49.044226| MAIN > Set flipX to 1
WfsArbitrator_46405|INF| 29|2022-11-23 18:02:49.044234| MAIN > Set flipY to 0
WfsArbitrator_46405|WAR| 30|2022-11-23 18:02:49.044267| MAIN > ncpaTrackInterval keyword not defined in config file. Using default value of 10 seconds
WfsArbitrator_46405|INF| 31|2022-11-23 18:02:49.044276| MAIN > Set ncpaTrackInterval to 10
WfsArbitrator_46405|INF| 32|2022-11-23 18:02:49.044284| MAIN > Set rerotMinPos to -803675856
WfsArbitrator_46405|INF| 33|2022-11-23 18:02:49.044300| MAIN > Set rerotMaxPos to -803675856
WfsArbitrator_46405|INF| 34|2022-11-23 18:02:49.044311| MAIN > read TT Offset config file /home/AOeng/live/aoroot/calib/wfs/current/tt_offset/tt_offset_elevation.txt
WfsArbitrator_46405|INF| 35|2022-11-23 18:02:49.045139| MAIN > Read TT Offset file with 436 points
WfsArbitrator_46405|INF| 36|2022-11-23 18:02:49.045154| MAIN > read TT Offset config file is OK
WfsArbitrator_46405|INF| 37|2022-11-23 18:02:49.045164| MAIN > reading Encoder correction matrix file /home/AOeng/live/aoroot/calib/wfs/current/tt_offset/encoder_to_volts.txt
WfsArbitrator_46405|INF| 38|2022-11-23 18:02:49.045198| MAIN > read Encoder correction matrix file is OK
WfsArbitrator _46405|FAT| 39|2022-11-23 18:02:49.045208| MAIN > Some problem occurred (i.e. MsgD offline): AOApp not started (run not executed)
WfsArbitrator_46405|INF| 40|2022-11-23 18:02:49.045229| MAIN > Communication with MsgD stopped

Message to Fabio et al.

OOA will check the system once they are in Tucson. Maybe Saturday or sunday.

No more work with the DX soul.

-- JuanCarlosGuerra - 23 Nov 2022
Topic revision: r2 - 24 Nov 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.