Power outage: JP recovered both adsec's after the ok from Tim. DX set with 623 modes, and SX with 641 modes. rested DX.

ARGOS swingarm will not deploy: input parameter error. Reset did not resolve. Calling Juan Carlos for assistance

Closed loop with gains 1.8, 0.6, 0.35. "prettiest loop ever to quote our team.

Baysides were not updated to the desired positions from this weekend in the fov_select. Updated and when reclosing, adsec failure:

AdSecArbitrator_60269|INF| 558|2022-11-21 21:07:17.618462| MAIN > Received cmd: Offloading(1)
AdSecArbitrator_60269|INF| 559|2022-11-21 21:07:17.618494| COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)
AdSecArbitrator_60269|INF| 560|2022-11-21 21:07:17.626290| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_60269|ERR| 561|2022-11-21 21:07:21.645572| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_60269|ERR| 562|2022-11-21 21:07:21.645604| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20222111 21:07:21.6465 Alert: Error: COILS DISABLED
AdSecArbitrator_60269|INF| 563|2022-11-21 21:07:21.717084| ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2022/11/21/ADAPTIVE-SECONDARY_00001669064841_20221121_210721.bin
AdSecArbitrator_60269|INF| 564|2022-11-21 21:07:21.717105| ALERTHANDLER > Processdump is skipped
20222111 21:07:21.7173 Alert: DumpSaved: DumpSaved vector ready
AdSecArbitrator_60269|ERR| 565|2022-11-21 21:07:25.699587| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_60269|ERR| 566|2022-11-21 21:07:25.699618| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20222111 21:07:25.7004 Alert: Error: COILS DISABLED

Adsc_stop/start. Flat set with 641 modes

14:24 OCAM negative counts. Rebin resolved.

Baysides needed additional tweaking: 66.1, 20.3, 62