Staff:

LBTO: Josh, andrew, Juan Carlos

Observer: Remote

Summary.

Alta.

alta_20221111_0.png alta_20221111_1.png

Details.

5:11 PM

power on
  • ok
Ocam.
  • Triangle pattern.
  • power cycle BCU2k.
  • setup 1x1 cropped.
  • OK
sky cloudy.

Observer mentioned that the AO program requrie photometric sky. Deciton is not going with AO
  • sunset not photometric.
  • Configure for Bino Luci
  • after monoluci
  • Try an OSCO
sky_20221111_sunset.png

5:30 PM

Open shutters.

5:39PM

BCU47 not yet in temperature 5.3C

5:55 PM
  • PresetAO
  • gopt on
  • taking data.
  • variable sky.
  • peak jitter at 50Hz and 240Hz.
  • modal SR 80
  • optimize gain:20221112_010137 g_tt_2.02_ho1_0.74_ho2_0.48
  • gopt: g_tt_0.74_ho1_0.27_ho2_0.19
  • jitter-20221111_osco0.png
  • sporadic peaks at 130Hz
  • luci1.20221112.0016-35.fits
  • SR: 55 to 60
  • luc .0030
  • the static speckles(?)
  • 50Hz peak frequency->20221112_010700
luci1.2021112.0030.png
  • The correction is good, there is a diagonal elongation
  • Osco OK
Moving to seeing limited OBS.

6:22PM
  • Ocam warm.
6:29PM
  • Confirm not AO
  • Power off WFS

data.

idl_ctrl_7921 |INF| 2379|2022-11-12 00:58:39.668062| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6033|2022-11-12 01:04:03.475890| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010401/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6043|2022-11-12 01:04:17.004834| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010416/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6050|2022-11-12 01:04:29.214350| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010429/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6115|2022-11-12 01:06:35.483142| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010635/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6125|2022-11-12 01:06:47.643342| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010647/adsec.sav') & print, errcode

idl_ctrl_7921 |INF| 6135|2022-11-12 01:07:00.089684| MAIN > Executing command: errcode= fsm_savestatus('/local/aomeas/adsec_data/20221112/Data_20221112_010700/adsec.sav') & print, errcode

-- JuanCarlosGuerra - 12 Nov 2022