SHARK Alignment

16:34
  • Zero/Negative Flux on OCAM
  • Re-binning fixed it.
17:30
  • Finding the source.
17:45
  • Failure during optimize gain.
18:03
  • Found the source, centering it on SHARK
18:14
  • Doing some focus tweaks.
20:15
  • Hexapod stopped offloading and the loop opened. I had to re-home the hexapod.
20:52
  • Negative flux on ocam, loop didn't open, tried to pause.
  • Thu Nov 10 20:51:56.788 2022 aos.Pause{FLAO}.started - Pause{FLAO}[5305]
    Thu Nov 10 20:51:56.956 2022 aos.Pause{FLAO}.failed - Pause{FLAO}[5305] - [AOException] RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
  • Re-binned the OCAM and manually re-closed the loop.
21:43
  • We've been running with a disturbance for the last 20 min or so.
  • /local/aomeas/adsec_calib/CMD/disturb/dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • They wanted 0.5" in single pass, so that's what we've got.
22:29
  • There may have been a problem with the 1.5" disturb. I applied it wrong and we couldn't get good correction.