Details.

Power on.

7|2022-09-23 15:57:01.006433| MAIN > Loading irtc
WfsArbitrator_127676|INF| 68|2022-09-23 15:57:01.007216| MAIN > Exception loading device irtc: thGetVar L.IRTC.DARK.REQ error(-3006): Variable not found error
WfsArbitrator_127676|INF| 69|2022-09-23 15:57:01.007309| MAIN > Waiting for network connection
WfsArbitrator_127676|INF| 70|2022-09-23 15:57:01.007394| MAIN > setup unit W SOUL #1

Restart the AOS L.

IT CAN NOT BE SET THE flaowfs..

restart the aos left.

nstr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 16:44:47.884 2022 aos.info - WFS source set to: FLAOWFS

set flat.

641 modes.

hexapod: 2.79,0.8 -1.4,100,-131,0

Fri Sep 23 17:14:10.785 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[4] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 17:14:10.805 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 17:14:10.851 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

CLOSE LOOP NCPA.

optimize gain.

first pass no skipframes.

2.77,0.69,0.56

it doen;t looks too good the modalplot...

Tn:20220923_173252

restart bcu2k.

Fri Sep 23 17:46:12.188 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[6] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 17:46:12.205 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 17:46:12.262 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

727|2022-09-23 17:50:20.441231| MAIN > Maximum mode index used to apply flat -> # 608

flat_20220924.png

rest.

900|2022-09-23 17:53:59.382709| MAIN > Maximum mode index used to apply flat -> # 641

Fri Sep 23 17:54:01.036 2022 aos.info - FLAO: Adsec 672b-left shell set done.
Fri Sep 23 17:55:03.686 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[8] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 17:55:03.703 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 17:55:03.743 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

auxloop is not gettign data.?

TN:20220923_181011

optimize gain:

2.0,0.67,0.41

_181405

gopt.

_181733

SR attenuation in H band due to TT jitter 0.90679192

_181733

SR 65

modaklSR:85

_182018

sr65%

gopt_modalplot_20220923_2.png

ncpa on:

_182247

no 127Hz visible.

SR 69

_182513

SR 70

ttjitter_20220923_182247.png

hold the gain:

gainto 0.1

rot 310

reclose the loop, it looks unstable after the rotation...

stopAO

new preset.
Fri Sep 23 18:31:22.126 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[10] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 18:31:22.143 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 18:31:22.200 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

1.92,0.5,0.52

_183637,_183743

SR68%

modalplot_310_20220923.png

ncpaon

_183926,_184028

SR72

rot280

nFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 18:43:07.818 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 18:43:07.875 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

check for the gain..

_184821,_184927

ncpaon.

_185108,_185309

sr75

rot 250

Fri Sep 23 18:55:36.052 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[14] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 18:55:36.068 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 18:55:36.122 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Sep 23 18:55:36.798 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

gain:2.37,0.5,0.48

_185946

optical loop data and auxloop, the aux loop don;t show the modalplot.

gopt.

failed.


2022-09-23 19:01:02.553161| -13006 - [AOException] RETRY: Current optical gain is zero! Cannot continue (-5002) VALUE_OUT_OF_RANGE_ERROR

second try:

wind speed not available.

restart gopt optical loop data process.

gopt flao

same error

2022-09-23 19:03:45.425212| -13006 - [AOException] RETRY: Cannot read current optical gain value (-5001) TIMEOUT_ERROR

optimize again:

failed.

Loop open

CIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 19:08:35.107 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 19:08:35.161 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

optimize gain:

1.56,0.5,0.52

aux loop has the images.

gopt ok

_191519,_191631

SR:71

ncpa on

_191917,_192026

sr80

rot 220

ront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 19:23:03.394 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 19:23:03.448 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

_192832,_192941.

_193053,_193250

SR73.

ncpaon

_193541,_193745.

SR76

rot190

Fri Sep 23 19:39:46.265 2022 aos.AcquireRef{FLAO}.complete - AcquireRef{FLAO}[19] - dx:-1.40267 dy:0.0320827 slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Fri Sep 23 19:40:22.238 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[20] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Sep 23 19:40:22.258 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 23 19:40:22.312 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

194742,

ncpaon

_194935

12:55 done

test Luci irc.

- JuanCarlosGuerra - 23 Sep 2022
Topic revision: r2 - 23 Sep 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.