previous activity, save bcu2k firmware. Arcetri (Fabio)

11:00am
  • Powerup.
  • ok
  • ocam
  • notlive.
  • masterdiagnostic process is up
MasterDiagnostic_20368|WAR| 386|2022-09-08 18:17:55.889991| BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 4308. instad of 2860
MasterDiagnostic_20368|WAR| 387|2022-09-08 18:17:55.890008| BCU39 > FramesDownloader BCU39: frame % successfully discarded !
MasterDiagnostic_20368|WAR| 387|2022-09-08 18:17:55.890008| BCU39 > .

power cycle BCU2K.

WfsArbitrator _20470|DEB| 137|2022-09-08 18:14:49.672621| MAIN > arbFunc updateModulationInternal done.
20220809 18:19:24.0415 Alert: Error: LOST COMMUNICATION WITH SLOPE COMPUTER

setting up CCD

back to live.

asterDiagnostic_20368|WAR| 515|2022-09-08 18:20:52.925508| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_20368|WAR| 516|2022-09-08 18:20:56.153500| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 12 for frameId 172 (instead of packetId 11 for frameId 172)
MasterDiagnostic_20368|WAR| 517|2022-09-08 18:20:56.153565| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_20368|WAR| 518|2022-09-08 18:20:56.153645| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 13 for frameId 172 (instead of packetId 0 for frameId 172)
MasterDiagnostic_20368|WAR| 519|2022-09-08 18:20:56.153673| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_20368|WAR| 520|2022-09-08 18:20:56.153738| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 14 for frameId 172 (instead of packetId 0 for frameId 172)
MasterDiagnostic_20368|WAR| 521|2022-09-08 18:20:56.153763| BCU39 > FramesDownloader BCU39: packet successfully ignored !

Set freq 900

ok.

set flat.

idl_20046 |INF| 4966|2022-09-08 18:25:46.946314| MAIN > Maximum mode index used to apply flat -> # 641

Act 224 shows to have 60.5um all those around 50 top 54 um

flat_20220908.png

Thu Sep 8 18:31:26.522 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:13.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Sep 8 18:31:26.537 2022 aos.info - WFS source set to: FLAOWFS
Thu Sep 8 18:31:26.609 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

OCAM not live.

loop closed working... badly

adsec to failure.

adsc_stop/start

32234 |INF| 547|2022-09-08 18:40:05.799143| MAIN > Maximum mode index used to apply flat -> # 641

bin3

shutter 48

Thu Sep 8 19:04:58.545 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[7] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Sep 8 19:04:58.561 2022 aos.info - WFS source set to: FLAOWFS
  • dist 500, 1.5"
  • luci filter j
  • TN 20220908_
  • b('20220908_191438',191621
  • modal Sr 40%
  • loop pause
  • luci dark.
  • resume
  • TN:_192016
  • luci images: luci1.20220909_0003,4,5,6
  • sloperms 4.8

bin3_20220908.png
  • SR 12% (J band)
  • H band due to TT jitter 0.26338433
  • wavefront residual: (TT, tot w/o TT): 516.253, 260.477

tiptilt_b3_20220908.png

modal_b3_20220908.png

bin4

  • shutter 44
  • mag16.9
  • dist 500, 1.5"
strange the pupils seems out.

loaded pupil 20220831_070258

wobble start.

12:44PM

strange the control of the camera lens is not running,

doing the wobble the CL stay in the same positions.estart the wfsarbitrator.

camera lens seems working now.

back rotator to 341.

Stop

Preset

Thu Sep 8 19:53:25.236 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[15] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

loaded pupil 20220831_070258

wobble.

b4_wobble_check_20220908.png

>>> makePupils.movePupils('20200916_173857',1,-1,240,5)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202201/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202201/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202201
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202201"
'20220908_202201'

X too positive.

'20220908_202201'
>>> makePupils.movePupils('20200916_173857',-1,-1,240,5)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202427/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202427/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202427
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_202427"
'20220908_202427'

1:26Pm

wobble pupll '20220908_202427'

table_LUCIFER_ACE-AO.txt.20220908

table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO.txt.20220908

Thu Sep 8 20:42:55.997 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[17] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

loaded dist 1.5 200Hz

too at the limit in X (?)

loaded original pupil #16

move rot to 300.

loop not good... pupils not illuminated.

>>> makePupils.movePupils('20200916_173857_LBTI',-1,-1,240,5)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_210505/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_210505/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_210505
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220908_210505"
'20220908_210505'
>>>

The shifted pupils shows to be unstable and in a optimization gain shows a high number of skip frames. Pupils not even illuminated.

bin4_shiftedpupil_20220908.png

close loop stable wiht the original pupil.

optimize gain.

ok

change pupil file in the AO table and preset

Thu Sep 8 21:12:38.460 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[21] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • loaded dist1.5 500
  • better with the original pupil
  • optimize gain good.
  • with the pupils shifted not good.
  • Original pupil.
bin4-originalpupil_20220908.png

TN:212208,_

during the second TN the wfs goes offline...

WfsArbitrator _22102|DEB| 825|2022-09-08 21:23:26.527724| MAIN > arbFunc saveIrtcInternal done.
WfsArbitrator_22102|DEB| 826|2022-09-08 21:24:30.275602| MAIN > arbFunc doStopLoop (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_22102|DEB| 827|2022-09-08 21:24:30.277396| MAIN > arbFunc doStopLoop done.
20220809 21:24:31.3772 Alert: Error: LOST COMMUNICATION WITH SLOPE COMPUTER

Thu Sep 8 21:33:17.706 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[24] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

cancel.

loaded the pupil in the AOtable

Thu Sep 8 21:35:09.371 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[25] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

restart the WFS.

WfsArbitrator _118597|ERR| 94|2022-09-08 21:53:21.949592| MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR

operate.

bayside stage timeout X axis

ator_118597|INF| 211|2022-09-08 21:57:55.404348| MAIN > Timeout waiting for baysidex.L.STATUS - TIMEOUT_ERROR
WfsArbitrator_118597|ERR| 212|2022-09-08 21:57:55.404635| MAIN > Exception: Timeout waiting for baysidex.L.STATUS
WfsArbitrator_118597|ERR| 213|2022-09-08 21:57:55.404768| MAIN > Timeout waiting for baysidex.L.STATUS (-5001) TIME

Restart w software.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Sep 8 22:03:58.094 2022 aos.info - WFS source set to: FLAOWFS
Thu Sep 8 22:03:58.150 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.fits

WfsArbitrator _148032|INF| 187|2022-09-08 22:04:36.425898| MAIN > Setting tiptilt to amp= 0.00, freq= 0.00, offx= 0.00, offy= 0.00
WfsArbitrator_148032|ERR| 188|2022-09-08 22:04:38.556473| MAIN > exception ::AODefs::AOException
WfsArbitrator_148032|ERR| 189|2022-09-08 22:04:38.556534| MAIN > {
WfsArbitrator_148032|ERR| 190|2022-09-08 22:04:38.556559| MAIN > code = -1
WfsArbitrator_148032|ERR| 191|2022-09-08 22:04:38.556595| MAIN > what = [AOException] /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/pixelGating.txt (code -1010) File open/read/write error File BCUlbt.cpp line 485
WfsArbitrator_148032|ERR| 192|2022-09-08 22:04:38.556631| MAIN > }

pupil has a wrong file.

hu Sep 8 22:09:06.982 2022 aos.info - FLAO: WFS: configuring CCDs
Thu Sep 8 22:09:09.610 2022 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[31] - [AOException] presetAO: FATAL - exception ::AODefs::AOException{ code = -1 what = [AOException] /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/current/pixelGating.txt (code -1010) File open/read/write error File BCUlbt.cpp line 485}

file wrong checked the file in the AO table..

corrected.

preset ok.

wobble with original pupil:

3:20PM

bin4-pup20200916_173554.png

Thu Sep 8 22:37:26.561 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[36] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Sep 8 22:37:26.578 2022 aos.info - WFS source set to: FLAOWFS
Thu Sep 8 22:37:26.632 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.

optimize ok

bin4-originalpupil_20220908.png

TN: _224307.
  • better TT correction, attenuiation 0.66529422

gopt on

optimize_gopt-20220908_b4.png

TN:_224515 (dark)

_224633

bin4-20220908_224633.png

modalSR 20%

_224829

bin4_20220908_224829.png

modalplot_20220908_224829.png

pause

luci dark

0013.fits 10 frames

0014.fits (5 frames)

REsume

TN:_225243
  • Wavefront residual, CL res (TT, tot w/o TT): 454.816, 379.272
  • There is a high tilt no corrected. ->tt ateniation 0.5 visible in the PSF.

bin4-mag16p5_Jband.png

bin4-atteuation..png
  • saved TTM table with the bin4 pupil.
  • table_LUCIFER_TTM-AO.txt -> table_LUCIFER_TTM-AO.txt.20220908_v2

3:57PM STOP

WfsArbitrator _22102|INF| 816|2022-09-08 21:22:02.653801| MAIN > Closing gopt tracking loop
WfsArbitrator_22102|DEB| 817|2022-09-08 21:22:02.654236| MAIN > arbFunc startGoptInternal done.
WfsArbitrator_22102|DEB| 818|2022-09-08 21:22:10.002787| MAIN > arbFunc doSaveStatus (<AdOpt.thAOApp.thAOApp instance at 0x3759680>, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20220908/Data_20220908_212208/wfs.fits')
WfsArbitrator_22102|DEB| 819|2022-09-08 21:22:10.008310| MAIN > getSetupFits(): fits header created
WfsArbitrator_22102|DEB| 820|2022-09-08 21:22:10.053405| MAIN > arbFunc doSaveStatus done.
WfsArbitrator_22102|DEB| 821|2022-09-08 21:22:10.054942| MAIN > arbFunc saveIrtcInternal (<AdOpt.thAOApp.thAOApp instance at 0x3759680>, 'FLAOWFS', 'LUCIFER', '/local/aomeas/adsec_data/20220908/Data_20220908_212208/luci.fits', 10, 'luci')
WfsArbitrator_22102|INF| 822|2022-09-08 21:22:10.055014| MAIN > saveIrtcInternal(): starting measure, 10 frames
WfsArbitrator_22102|DEB| 823|2022-09-08 21:23:23.047110| MAIN > getSetupFits(): fits header created
WfsArbitrator_22102|INF| 824|2022-09-08 21:23:26.485913| MAIN > saveIrtc(): done
WfsArbitrator_22102|DEB| 825|2022-09-08 21:23:26.527724| MAIN > arbFunc saveIrtcInternal done.
WfsArbitrator_22102|DEB| 826|2022-09-08 21:24:30.275602| MAIN > arbFunc doStopLoop (<AdOpt.thAOApp.thAOApp instance at 0x3759680>, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_22102|DEB| 827|2022-09-08 21:24:30.277396| MAIN > arbFunc doStopLoop done.


fsArbitrator_22095|INF| 1593|2022-09-08 21:21:25.524598| WFS > Python command: WfsArbScripts.startGopt(self, sensor = 'FLAOWFS', instr = 'LUCIFER')
WfsArbitrator_22095|INF| 1594|2022-09-08 21:22:02.654356| WFS > Command returns success .
WfsArbitrator_22095|INF| 1595|2022-09-08 21:22:08.068457| ASYNCCOMMANDHANDLER > COMMAND received from optloopdiagngui.L
WfsArbitrator_22095|INF| 1596|2022-09-08 21:22:08.068823| OPTLOOPDIAG > Executing save...
WfsArbitrator_22095|INF| 1597|2022-09-08 21:22:10.002327| WFS > Executing saveStatus...
WfsArbitrator_22095|INF| 1598|2022-09-08 21:22:10.002415| WFS > Python command: WfsArbScripts.saveStatus(self, sensor = 'FLAOWFS', instr = 'LUCIFER', outputFile = '/local/aomeas/adsec_data/20220908/Data_20220908_212208/wfs.fits')
WfsArbitrator_22095|INF| 1599|2022-09-08 21:22:10.053584| WFS > Command returns success .
WfsArbitrator_22095|INF| 1600|2022-09-08 21:22:10.054594| WFS > Executing saveLuci...
WfsArbitrator_22095|INF| 1601|2022-09-08 21:22:10.054684| WFS > Python command: WfsArbScripts.saveLuci(self, sensor = 'FLAOWFS', instr = 'LUCIFER', filename = '/local/aomeas/adsec_data/20220908/Data_20220908_212208/luci.fits', num = 10)
WfsArbitrator_22095|INF| 1602|2022-09-08 21:23:26.527882| WFS > Command returns success .
WfsArbitrator_22095|ERR| 1603|2022-09-08 21:24:23.071433| MAIN > Cannot read telescope rotator position: [AOVarException] thGetVar error (code -5001) Timeout errorVariable: AOS.L.ROTATOR.ANGLE@M_ADSEC (type REAL_VARIABLE, len 1)
WfsArbitrator_22095|ERR| 1603|2022-09-08 21:24:23.071433| MAIN > .
WfsArbitrator_22095|ERR| 1604|2022-09-08 21:24:24.071707| MAIN > Cannot read the telescope elevation: [AOVarException] thGetVar error (code -5001) Timeout errorVariable: AOS.TEL.EL@M_ADSEC (type REAL_VARIABLE, len 1)
WfsArbitrator_22095|ERR| 1604|2022-09-08 21:24:24.071707| MAIN > .
WfsArbitrator_22095|ERR| 1605|2022-09-08 21:24:26.072156| MAIN > Cannot read telescope rotator position: [AOVarException] thGetVar error (code -5001) Timeout errorVariable: AOS.L.ROTATOR.ANGLE@M_ADSEC (type REAL_VARIABLE, len 1)
WfsArbitrator_22095|ERR| 1605|2022-09-08 21:24:26.072156| MAIN > .
WfsArbitrator_22095|ERR| 1606|2022-09-08 21:24:27.072464| MAIN > Cannot read the telescope elevation: [AOVarException] thGetVar error (code -5001) Timeout errorVariable: AOS.TEL.EL@M_ADSEC (type REAL_VARIABLE, len 1)
WfsArbitrator_22095|ERR| 1606|2022-09-08 21:24:27.072464| MAIN > .
WfsArbitrator_22095|ERR| 1607|2022-09-08 21:24:29.073050| MAIN > Cannot read telescope rotator position: [AOVarException] thGetVar error (code -5001) Timeout errorVariable: AOS.L.ROTATOR.ANGLE@M_ADSEC (type REAL_VARIABLE, len 1)
WfsArbitrator_22095|ERR| 1607|2022-09-08 21:24:29.073050| MAIN > .
WfsArbitrator_22095|INF| 1608|2022-09-08 21:24:29.235307| ASYNCCOMMANDHANDLER > COMMAND received from optloopdiagngui.L
WfsArbitrator_22095|WAR| 1609|2022-09-08 21:24:29.235485| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1610|2022-09-08 21:24:29.235735| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1611|2022-09-08 21:24:29.235934| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1612|2022-09-08 21:24:29.238625| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1613|2022-09-08 21:24:29.238882| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1614|2022-09-08 21:24:29.241180| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1615|2022-09-08 21:24:29.243170| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1616|2022-09-08 21:24:29.243418| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1617|2022-09-08 21:24:29.243644| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1618|2022-09-08 21:24:29.246907| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1619|2022-09-08 21:24:29.247172| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1620|2022-09-08 21:24:29.248572| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1621|2022-09-08 21:24:29.248792| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|WAR| 1622|2022-09-08 21:24:29.249728| MAIN > AlertNotifier for wfscontrol.L is already installed!
WfsArbitrator_22095|WAR| 1623|2022-09-08 21:24:29.288453| MAIN > AlertNotifier for wfscontrol1.L is already installed!
WfsArbitrator_22095|INF| 1624|2022-09-08 21:24:30.275175| MAIN > Processing alert 3002 (Error) from slopecompctrl.L: LOST COMMUNICATION WITH SLOPE COMPUTER
WfsArbitrator_22095|INF| 1625|2022-09-08 21:24:30.275226| WFS > Executing stopLoop...


WfsArbitrator _22102|INF| 865|2022-09-08 21:33:19.861707| MAIN > Turning on PROG_BCU_47
WfsArbitrator_22102|INF| 866|2022-09-08 21:33:19.861860| MAIN > Turning off RESET_BCU_47
WfsArbitrator_22102|INF| 867|2022-09-08 21:33:21.128531| MAIN > Resetting bcu47...
WfsArbitrator_22102|INF| 868|2022-09-08 21:33:29.262325| MAIN > Turning on RESET_BCU_47
WfsArbitrator_22102|INF| 869|2022-09-08 21:33:31.131128| MAIN > Waiting for bcu47 to come up...
WfsArbitrator_22102|INF| 870|2022-09-08 21:33:43.324209| MAIN > bcu47 OK...

-- JuanCarlosGuerra - 08 Sep 2022
I Attachment Action Size Date Who Comment
auxloop_20220908_.pngpng auxloop_20220908_.png manage 143 K 09 Sep 2022 - 00:59 JuanCarlosGuerra  
b4_wobble_check_20220908.pngpng b4_wobble_check_20220908.png manage 49 K 08 Sep 2022 - 20:27 JuanCarlosGuerra  
bin3_20220908.pngpng bin3_20220908.png manage 40 K 09 Sep 2022 - 18:31 JuanCarlosGuerra  
bin4-20220908_224633.pngpng bin4-20220908_224633.png manage 41 K 09 Sep 2022 - 00:54 JuanCarlosGuerra  
bin4-atteuation..pngpng bin4-atteuation..png manage 13 K 09 Sep 2022 - 00:52 JuanCarlosGuerra  
bin4-mag16p5_Jband.pngpng bin4-mag16p5_Jband.png manage 43 K 09 Sep 2022 - 00:48 JuanCarlosGuerra  
bin4-originalpupil_20220908.pngpng bin4-originalpupil_20220908.png manage 1 MB 09 Sep 2022 - 01:00 JuanCarlosGuerra  
bin4-pup20200916_173554.pngpng bin4-pup20200916_173554.png manage 66 K 09 Sep 2022 - 00:39 JuanCarlosGuerra  
bin4_20220908_224829.pngpng bin4_20220908_224829.png manage 41 K 09 Sep 2022 - 00:57 JuanCarlosGuerra  
bin4_shiftedpupil_20220908.pngpng bin4_shiftedpupil_20220908.png manage 332 K 09 Sep 2022 - 01:07 JuanCarlosGuerra  
flat_20220908.pngpng flat_20220908.png manage 146 K 08 Sep 2022 - 18:27 JuanCarlosGuerra  
modal_b3_20220908.pngpng modal_b3_20220908.png manage 61 K 09 Sep 2022 - 18:48 JuanCarlosGuerra  
modalplot_20220908_224829.pngpng modalplot_20220908_224829.png manage 18 K 09 Sep 2022 - 00:57 JuanCarlosGuerra  
optimize_gopt-20220908_b4.pngpng optimize_gopt-20220908_b4.png manage 118 K 08 Sep 2022 - 22:48 JuanCarlosGuerra  
tiptilt_b3_20220908.pngpng tiptilt_b3_20220908.png manage 41 K 09 Sep 2022 - 18:46 JuanCarlosGuerra  
Topic revision: r6 - 09 Sep 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback