Details.

Waiting for TMS.

Contacting telescope manager and TMS team is not yet at the mountain, taking the time for a close loop check.

10:00am power on

ocam ok.

set flat

046 |INF| 2303|2022-09-06 17:02:03.389786| MAIN > Maximum mode index used to apply flat -> # 641bin1 checkout.

Tue Sep 6 17:02:04.974 2022 aos.info - FLAO: Adsec 672b-left shell set done.

Tue Sep 6 17:02:31.460 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Sep 6 17:02:31.477 2022 aos.info - WFS source set to: FLAOWFS
Tue Sep 6 17:02:32.491 2022 aos.info - FLAO: WFS: loading setup for LU

spot not found.

The new position is due to a change in the M3 positions found last night,

hexapod-newpos_20220906.png

found the spot , new position for the hexapod.

2.33,1.3,-1.43,90,-170,0

Cancel preset new preset.

Ocam not live. (?)
  • power cycle the bcu2k
  • load conf.
  • not live.
  • Power cycle BCU2k
  • same, not live.
erDiagnostic_5946|WAR| 3034|2022-09-06 16:59:15.428255| BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 2940. instad of 2860
MasterDiagnostic_5946|WAR| 3035|2022-09-06 16:59:15.428282| BCU39 > FramesDownloader BCU39: frame % successfully discarded !
MasterDiagnostic_5946|WAR| 3035|2022-09-06 16:59:15.428282| BCU39 > .
MasterDiagnostic_5946|WAR| 3036|2022-09-06 16:59:15.428328| BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 2940. instad of 2860
MasterDiagnostic_5946|WAR| 3037|2022-09-06 16:59:15.428354| BCU39 > FramesDownloader BCU39: frame % successfully discarded !
MasterDiagnostic_5946|WAR| 3037|2022-09-06 16:59:15.428354| BCU39 > .
Process killed!!
MasterDiagnostic_5946|FAT| 3038|2022-09-06 17:22:31.652400| MAIN > masterdiagnostic.L terminated by sysprocesses.L00
MasterDiagnostic_5946|INF| 3039|2022-09-06 17:22:32.004842| MAIN > DESTROYING THE APPLICATION...
  • lost communicaiton wiht the AGW, Warbitrator went offline, all the devices showed to be disconnected.
  • Restart the sxwfs software.
  • Ocam live.
Tue Sep 6 17:33:51.341 2022 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[5] - dx:0.936579 dy:0.219705 slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Tue Sep 6 17:34:51.774 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Tue Sep 6 17:34:51.791 2022 aos.info - WFS source set to: FLAOWFS
Tue Sep 6 17:34:51.843 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits

bin1_gopt_optimize.png

TN_174102,_174245,_174601 (N375)

TN+luci: _174759 (65%)

loop stable

modal SR 85

ncpa on:_175011 (70%) better...it still some residual in the TT

bin1_psf_ncpaon_20220906.png

bin1_tt-residual_20220906.png

bin2.

ntGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue Sep 6 17:55:29.035 2022 aos.info - WFS source set to: FLAOWFS
Tue Sep 6 17:55:29.147 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue Sep 6 17:55:29.813 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize

gopt

1.59,0.24,0.24

bin2_gopt-optimize-20220906_2.png

modal SR 85%

TN+luci:_180252,18,04,22

ncapon :_180540

bin2_psf-20220906.png

stop 11:00 am

Autogain.cong.

bin2 for 750 to 1000

in2_f2_nframes int 50

bin2_f2_max_tt float 40.0

bin2_f2_max_ho1 float 4.0

bin2_f2_max_ho2 float 2.0

bin2_f2_ho_middle int 50

bin2_f2_quadratic_tt int 0

bin2_f2_refine_down_factor float 0.5

bin2_f2_refine_up_factor float 1.5

bin2_f2_max_iterations int 4

-- JuanCarlosGuerra - 06 Sep 2022