Details.

1:10PM power on WFS.

Ocam OK

Telescope released for SoulSX.

Luci1 is having a problem and troubleshooting on hold.

Deploy Argos cal unit.

Error hardware

Reset hardware two times and the hardware bcame available, error clear.

Adsec set flat.

641 modes.

flat-20220903.png

Center star.

sArbitrator_111617|INF| 210|2022-09-03 20:26:41.813061| MAIN > source_acq.acquire(): star found at X=650.95,Y=367.75
WfsArbitrator_111617|INF| 211|2022-09-03 20:26:41.813122| MAIN > source_acq.acquire(): current error X=1.273 mm, Y=1.080 mm
WfsArbitrator_111617|INF| 212|2022-09-03 20:26:52.920881| MAIN > Star found at x=81.9, y=162.2, flux=171.4
WfsArbitrator_111617|INF| 213|2022-09-03 20:26:52.922544| MAIN > source_acq.acquire(): star found at X=327.61,Y=648.63
WfsArbitrator_111617|INF| 214|2022-09-03 20:26:52.922603| MAIN > source_acq.acquire(): current error X=-1.253 mm, Y=-1.114 mm
WfsArbitrator_111617|ERR| 215|2022-09-03 20:26:59.732439| MAIN > RETRY: source_acq error: Star centering procedure failed to converge after 5 iterations (-20003) WFS

Wrong spot.

identify the right spot.

Set AOS for mag10.

CCD saturated.

FW2 empty.

FW2 Argos_QC still very bright.

AOS preset.

shutter full open

Sat Sep 3 20:38:35.935 2022 aos.info - Updated variable AOARB.L.AO_READY: 1
Sat Sep 3 20:38:35.936 2022 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[129] - dx:nan dy:nan slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Sat Sep 3 20:39:10.701 2022 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[130] Mode: Move stages, Automatic acquire

close loop bin1 ok.

hexapod after a few offloading.

moving to bin3..

shutter 48

set mag 16

Sat Sep 3 20:43:29.710 2022 aos.Stop{FLAO}.complete - Stop{FLAO}[132]
Sat Sep 3 20:44:35.493 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[133] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 3 20:44:35.510 2022 aos.info - WFS source set to: FLAOWFS

mag 15.8

saturation y+ expected.

load another pupil with two pixels shift

20220901_063305. Close loop.

rot@341

X=, y=

close loop error.

WfsArbitrator _111617|ERR| 471|2022-09-03 21:02:53.609621| MAIN > [Errno 28] No space left on device

The home directory has the 100 memory taken.

Filesystem Size Used Avail Use% Mounted on
/dev/mapper/vg00-root
5.9G 5.4G 255M 96% /
proc 0 0 0 - /proc
sysfs 0 0 0 - /sys
devpts 0 0 0 - /dev/pts
tmpfs 7.8G 12K 7.8G 1% /dev/shm
/dev/sda1 190M 40M 141M 22% /boot
/dev/mapper/vg00-home
788G 748G 0 100% /home
/dev/mapper/vg00-tmp 976M 11M 915M 2% /tmp
/dev/mapper/vg00-usr 5.8G 5.1G 487M 92% /usr
/dev/mapper/vg00-var 3.9G 703M 3.0G 20% /var
/dev/mapper/vg00-opt 488M 241M 223M 52% /opt
none 0 0 0 - /proc/sys/fs/binfmt_misc
sunrpc 0 0 0 - /var/lib/nfs/rpc_pipefs
192.168.39.20:/volume3/lbto_flao
18T 16T 2.0T 90% /ao-data
192.168.39.54:/local/aomeas
7.2T 5.7T 1.2T 84% /local/aomeas
archive-in:/mnt/newdata
11T 1.2T 9.6T 11% /mnt/newdata

Stop Chamber lights on

mean time clen up the disk.

deleted some auxloop data from the 16th (lab work)

3:00PM restarted.

setUP the ocam gave an error and the WFS can be configured.

Arbitrator_111617|INF| 478|2022-09-03 22:06:35.413472| MAIN > ccd.equalize_quadrants(): nothing to do for ocam2
WfsArbitrator_111617|ERR| 479|2022-09-03 22:06:39.518603| MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
  • process database filler doen't come up.
  • set ocam to ambient.
  • stop wfsarbitrator.
  • Power on again.
  • ok.
the ocam was seto to safe just in case it requires a power cycle and processes stopped.

info - FLAO: WFS: configuring CCDs
Sat Sep 3 22:18:57.213 2022 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[135] - [AOException] presetAO: FATAL - Timeout waiting for techviewctrl.L.STATUS (-5001) TIMEOUT_ERROR

Try again teh rpeset and it went ok.

ps -aef

kill the stuck dbfiller process after this the process came up live.

ocam at bin3 shows a bad frames.

bin3_badquadrants-20220903.png

change to bin1 .

the frames were OK.

Back to bin3

better bias.

bin3_after_backb1-20220903.png

loaded pupil 60

center pupil

with shutter 48 mag 16.6

shutter 52 ->mag 16

bin4

shutter 48

Sat Sep 3 22:41:59.140 2022 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[137] - dx:-2.01942 dy:0.583683 slNull: f1:0.0 f2:1.0 freq:391 mag:0 nBins:3 nModes:90 r0:nan snMode:0 strehl:0 ttMod:0
Sat Sep 3 22:42:48.995 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[138] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 3 22:42:49.011 2022 aos.info - WFS source set to: FLAOWFS

close loop, but the pupils not well flatted.

chagne to original pupil.

better close loop.

optimize gain fine not skip frames.

wrong tt

0.05,0.48,0.10

ramp up tt

optimize gain.

same TT.

optimize-bin4_20220903.png

TN:20220903_230439

Another preset B4 with shifted pupils.

WfsArbitrator _103577|DEB| 842|2022-09-03 23:19:53.206213| MAIN > getSetupFits(): fits header created
WfsArbitrator_103577|ERR| 843|2022-09-03 23:19:53.240454| MAIN > [Errno 28] No space left on device
WfsArbitrator_103577|DEB| 844|2022-09-03 23:19:53.240766| MAIN > arbFunc updateModulati

STOP.

4:21PM

IT HAS TO BE SOLVED THE DISK SPACE

[AOeng@soul-sxwfs ao]$ df -ah

Filesystem Size Used Avail Use% Mounted on

/dev/mapper/vg00-root

5.9G 5.4G 255M 96% /

proc 0 0 0 - /proc

sysfs 0 0 0 - /sys

devpts 0 0 0 - /dev/pts

tmpfs 7.8G 12K 7.8G 1% /dev/shm

/dev/sda1 190M 40M 141M 22% /boot

/dev/mapper/vg00-home

788G 748G 0 100% /home

/dev/mapper/vg00-tmp 976M 11M 915M 2% /tmp

/dev/mapper/vg00-usr 5.8G 5.1G 487M 92% /usr

/dev/mapper/vg00-var 3.9G 704M 3.0G 20% /var

/dev/mapper/vg00-opt 488M 241M 223M 52% /opt

none 0 0 0 - /proc/sys/fs/binfmt_misc

sunrpc 0 0 0 - /var/lib/nfs/rpc_pipefs

192.168.39.20:/volume3/lbto_flao

        1. T 16T 2.0T 90% /ao-data

192.168.39.54:/local/aomeas

7.2T 5.7T 1.2T 84% /local/aomeas

archive-in:/mnt/newdata

        1. T 1.2T 9.6T 11% /mnt/newdata

[AOeng@soul-sxwfs ao]$

moved the files M_* from 20220608 to shell.

Filesystem Size Used Avail Use% Mounted on

/dev/mapper/vg00-root

5.9G 5.4G 255M 96% /

proc 0 0 0 - /proc

sysfs 0 0 0 - /sys

devpts 0 0 0 - /dev/pts

tmpfs 7.8G 0 7.8G 0% /dev/shm

/dev/sda1 190M 40M 141M 22% /boot

/dev/mapper/vg00-home

788G 744G 3.8G 100% /home

/dev/mapper/vg00-tmp 976M 11M 915M 2% /tmp

/dev/mapper/vg00-usr 5.8G 5.1G 487M 92% /usr

/dev/mapper/vg00-var 3.9G 696M 3.0G 19% /var

/dev/mapper/vg00-opt 488M 241M 223M 52% /opt

none 0 0 0 - /proc/sys/fs/binfmt_misc

sunrpc 0 0 0 - /var/lib/nfs/rpc_pipefs

192.168.39.20:/volume3/lbto_flao

        1. T 16T 2.0T 90% /ao-data

192.168.39.54:/local/aomeas

7.2T 5.7T 1.2T 84% /local/aomeas

archive-in:/mnt/newdata

        1. T 1.2T 9.6T 11% /mnt/newdata

-- JuanCarlosGuerra - 03 Sep2022
Topic revision: r2 - 04 Sep 2022, JuanCarlosGuerra