Summary.

Details.

cp the AO table for a rest AO table with the new pupils found after the pupils shift tasks.

New table are:

ACE:

table_LUCIFER_ACE-AO.txt.20220902

TTM:

table_LUCIFER_TTM-AO.txt.20220902

To verify the pupils of the rec.

TTM table.

10.5 1.67E4 1 400 400 KL_v20 20190406_035330 pureIntegratorSOUL 20181103_001410 3 4 1 0 1 4 4.3 20 800 200 200 30 10e-9 80.0 -> same pupil as ACE.

12.5 2648 1 400 400 KL_v20 20190406_035330 pureIntegratorSOUL 20181103_001410 3 4 1 0 1 4 4.3 20 800 200 200 30 10e-9 80.0

12.5 2648 2 400 600 KL_v20 20190407_034820 pureIntegratorSOUL 20211125_011619 3 4 1 0 1 4 4.3 20 1200 200 600 30 10e-9 80.0 ->20181222_065045

13.0 1671 2 400 600 KL_v20 20190407_034820 pureIntegratorSOUL 20211125_011619 3 4 1 0 1 16 12.6 20 300 200 600 30 15e-9 80.0

14.0 665 2 400 600 KL_v20 20190407_034820 pureIntegratorSOUL 20211125_011619 3 4 1 0 1 16 12.6 20 300 200 600 30 15e-9 80.0

14.5 420 2 400 600 KL_v20 20190407_034820 pureIntegratorSOUL 20211125_011619 3 4 1 0 1 16 12.6 20 300 200 600 30 15e-9 80.0

14.5 420 4 400 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 600 200 600 30 20e-9 80.0 ->20200916_173857

15.5 167 4 400 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 600 200 600 30 20e-9 80.0

16.5 67 4 200 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 600 200 600 30 20e-9 80.0

17.5 26.5 4 200 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 600 200 600 30 20e-9 80.0

18.0 10.5 4 100 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 600 100 600 30 20e-9 80.0

20.5 1.7 4 100 600 KL_v20 20201013_212647 forgettingFactorBin4SOUL 20211205_144238 6 4 1 0 1 16 12.6 50 600 100 600 30 25e-9 80.0

We are using the same pupils for ACE and TTM.

4:00PM start up WFS.

Timeout Power on.

Poweron_timeout20220902.png WfsArbitrator _159194|INF| 58|2022-09-02 23:01:15.850535| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR
WfsArbitrator _159194|ERR| 59|2022-09-02 23:01:15.850633| MAIN > Exception: Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR
WfsArbitrator _159194|ERR| 60|2022-09-02 23:01:15.850683| MAIN > Cannot turn on PROG. Reason: Timeout waiting for powerboard.L.PROG_BCU_2K.CUR - TIMEOUT_ERROR (-1000) GENERIC_SYS_ERROR

Second Try.

OK

Ocam not live.

masterdoagnotic process down.

asterDiagnostic_184561|WAR| 207|2022-09-02 23:12:37.327820 BCU39 > .
MasterDiagnostic_184561|WAR| 208|2022-09-02 23:12:37.327910 BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 4710. instad of 2860
MasterDiagnostic_184561|WAR| 209|2022-09-02 23:12:37.327924 BCU39 > FramesDownloader BCU39: frame % successfully discarded !
MasterDiagnostic_184561|WAR| 209|2022-09-02 23:12:37.327924 BCU39 > .
MasterDiagnostic_184561|WAR| 210|2022-09-02 23:12:37.327941 BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 4710. instad of 2860
MasterDiagnostic_184561|WAR| 211|2022-09-02 23:12:37.327955 BCU39 > FramesDownloader BCU39: frame % successfully discarded !
MasterDiagnostic_184561|WAR| 211|2022-09-02 23:12:37.327955 BCU39 > .

Restart the process.

power cycle bcu2k

configure ocam bin1x1 cropped.

Argos cal unit.

The unit connects correctly.

Checking the status shows that the conditions are not fullfilled.

click reset

Condition fullfill and the arm can be deployed.

hexapod initial positions.

2.33,1.3,-1.4,220,-190,0

adsec flat

3371|2022-09-02 23:26:49.622202| MAIN > Maximum mode index used to apply flat -> # 641
idl_82396 |INF| 3372|2022-09-02 23:26:49.623188| MAIN > Min/Max delta command to apply for flattening ->

AOS preset.

Fri Sep 2 23:28:31.698 2022 aos.info - WFS source set to: FLAOWFS
Fri Sep 2 23:28:31.824 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Sep 2 23:28:33.002 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

Bin1

The estimated magnitude is 11.6

For the same Argos cal source shutter. Full-open

TN:20220902_235809

hexapod_argoscalunit.png

Cancel preset.

t Sep 3 00:00:56.645 2022 aos.AcquireRef{FLAO}.complete - AcquireRef{FLAO}[50] - dx:0.428018 dy:-0.541243 slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Sat Sep 3 00:10:40.228 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[51] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:

With the camera cooldown mag 9.8

close loop

TN:20220903_001539

bin2

shutter:60

mag 13

Sat Sep 3 00:16:25.819 2022 aos.info - Stages offset applied - dx: 0.325966; dy: -0.280909
Sat Sep 3 00:16:25.839 2022 aos.AcquireRef{FLAO}.complete - AcquireRef{FLAO}[52] - dx:0.325966 dy:-0.280909 slNull: f1:0.0 f2:1.0 freq:900 mag:0 nBins:1 nModes:501 r0:nan snMode:0 strehl:0 ttMod:0
Sat Sep 3 00:17:52.870 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[53] (aomode:ACE

TN:_002149

optimize gain OK.

optimizegain_B2.png

TN: 20220902_002448

gopt on

TN:_002609

Bin3 presetAO

Sat Sep 3 00:26:47.626 2022 aos.Stop{FLAO}.complete - Stop{FLAO}[56]
Sat Sep 3 00:27:05.212 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[57] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Sep 3 00:27:05.233 2022 aos.info - WFS source set to: FLAOWFS
Sat Sep 3 00:27:06.017 2022 aos.info - FLAO: WFS: loading setup for LUCIFER
Sat Sep 3 00:27:06.034 2022 aos.info - FLAO: WFS: configuring CCDs
Sat Sep 3 00:27:19.218 2022 aos.PresetAO{FLAO}.failed - PresetAO{FLAO}[57] - [AOException] presetAO: FATAL - [Errno 28] No space left on device

AOeng@soul-sxwfs processConf]$ df -h

Filesystem Size Used Avail Use% Mounted on
/dev/mapper/vg00-root
5.9G 5.4G 255M 96% /
tmpfs 7.8G 12K 7.8G 1% /dev/shm
/dev/sda1 190M 40M 141M 22% /boot
/dev/mapper/vg00-home
788G 748G 0 100% /home
/dev/mapper/vg00-tmp 976M 8.1M 917M 1% /tmp
/dev/mapper/vg00-usr 5.8G 5.1G 487M 92% /usr
/dev/mapper/vg00-var 3.9G 698M 3.0G 19% /var
/dev/mapper/vg00-opt 488M 241M 223M 52% /opt
192.168.39.20:/volume3/lbto_flao
18T 16T 2.0T 89% /ao-data
192.168.39.54:/local/aomeas
7.2T 5.7T 1.2T 84% /local/aomeas
archive-in:/mnt/newdata
11T 1.2T 9.6T 11% /mnt/newdata

remove some old files

preset ok.

Center pupil.

There is an error of x->0.5 y axis at +100

TO BE CHECKED WITH A PUPIL WOBBLE.

BIN4

SHUTTER 48

CENTER PPIL->OK.

CL:X=41,Y=39

AdSecArbitrator_82513|INF| 1355|2022-09-03 00:52:26.408843| COMMANDHANDLER > FSM (status: AORunning) has received command 2018 (SetGain)
AdSecArbitrator_82513|INF| 1356|2022-09-03 00:52:26.420576| COMMANDHANDLER > Command SetGain (code 2018) successfully completed
AdSecArbitrator_82513|INF| 1357|2022-09-03 00:52:26.426191| MAIN > Received cmd: Offloading(1)
AdSecArbitrator_82513|INF| 1358|2022-09-03 00:52:26.426230| COMMANDHANDLER > FSM (status: AORunning

trator_82513|INF| 1358|2022-09-03 00:52:26.426230| COMMANDHANDLER > FSM (status: AORunning) has received command 2029 (TTOffload)

AdSecArbitrator_82513|INF| 1359|2022-09-03 00:52:26.427540| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_82513|ERR| 1360|2022-09-03 00:52:30.465833| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_82513|ERR| 1361|2022-09-03 00:52:30.465858| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20220309 00:52:30.4667 Alert: Error: COILS DISABLED
AdSecArbitrator_82513|INF| 1362|2022-09-03 00:52:30.524285| ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2022/09/03/ADAPTIVE-SECONDARY_00001662166350_20220903_005230.bin
AdSecArbitrator_82513|INF| 1363|2022-09-03 00:52:30.524310| ALERTHANDLER > Processdump is skipped
20220309 00:52:30.5246 Alert: DumpSaved: DumpSaved vector ready

Recover Adsec.

wind speed come out disconnected.

idl_109372 |INF| 547|2022-09-03 01:03:31.642093| MAIN > Maximum mode index used to apply flat -> # 641

handover to telescope

power off.

failed that the Aux Unit is not power on

285|2022-09-03 01:38:22.638763| MAIN > Cannot turn on Cube stage. Reason: Timeout waiting for picctrl.L.cubestage.CUR - TIMEOUT_ERROR - GENERIC_SYS_ERROR
WfsArbitrator_27363|ERR| 286|2022-09-03 01:38:22.638868| MAIN > Exception: Cannot turn on Cube stage. Reason: Timeout waiting for picctrl.L.cubestage.CUR - TIMEOUT_ERROR
WfsArbitrator_27363|ERR| 287|2022-09-03 01:38:22.638930| MAIN > Cannot turn on Cube stage. Reaso

wfs_stop_all

w_start_all

power on

ok

power off

-- JuanCarlosGuerra - 02 Sep 2022