Summary.

  • Telescope at zenith and release for testing (~1:30PM). There is a gap of ~2h before the next storm arrives.
  • AO set to perform pupil wobble for Soul.
  • If time remain Argos close loo.

Details.

Power on.

W-stop/srt_all

showed the wfs arb was down and other process like aucloop.

Sent the messages to Brando for fiurther investigations.

crop of the terminal message:

-i pupilcheckocam2 ocam2
-- Stage masterdiagnostic housekeeperWFS dbfiller
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/MasterDiagnostic -i masterdiagnostic
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/housekeeperWFS -i housekeeperWFS
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/DBFiller -i dbfiller
Traceback (most recent call last):
File "/home/AOeng/live/aoroot/bin/w_start", line 256, in <module>
if name == '__main__': main()
File "/home/AOeng/live/aoroot/bin/w_start", line 144, in main
processControl.waitProcessStart( app, process)
File "/home/AOeng/live/aoroot/lib/python/AdOpt/processControl.py", line 243, in waitProcessStart
raise AdOptError ( AOErrCode ['TIMEOUT_ERROR'], "Timeout error waiting for process %s start" % process)
AdOpt.AOExcept.AdOptError: Timeout error waiting for process housekeeperWFS start - TIMEOUT_ERROR
keepUp start/running, process 27148
[AOeng@soul-sxwfs source]$ wfseng &
[1] 28337
[AOeng@soul-sxwfs source]$ Warning: cannot add process irtcccd
QLayout "unnamed" added to QMainWindow "unnamed", which already has a layout
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/WfsControl -i wfscontrol
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/sys_processes.py -i sysprocesses
startProcessByName(): starting process /home/AOeng/live/aoroot/bin/WfsControl -i wfscontrol

ocam 2k.
  • bad frame: " triangle feature"
  • Power cycle the bcu2k gave and ocam not live.
  • restart masterdiagnostic
  • power cycle bcu2k
  • reconfigure the ocam2k
  • ok.
flat:

7-01 20:43:51.084808| MAIN > Maximum mode index used to apply flat -> # 633

Fri Jul 1 20:47:43.451 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[120] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • ocam not live after closing the loop.
  • It will require a restart of the adsec amsterdiagnostics.
Crop of the Adsec masterdiagnostic MasterDiagnostic _55160|ERR| 3066|2022-07-01 20:51:57.050871|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: fcfcfcfc 41c0 5b8f40b
MasterDiagnostic _55160|ERR| 3066|2022-07-01 20:51:57.050871|ADAPTIVE-SECONDARY > .
MasterDiagnostic _55160|ERR| 3067|2022-07-01 20:51:57.050888|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic _55160|WAR| 3068|2022-07-01 20:51:57.050900|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic _55160|ERR| 3069|2022-07-01 20:51:57.051442|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic _55160|ERR| 3069|2022-07-01 20:51:57.051442|ADAPTIVE-SECONDARY > .
MasterDiagnostic _55160|ERR| 3070|2022-07-01 20:51:57.051461|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: fcfcfcfc 40c0 5b8f40c
MasterDiagnostic _55160|ERR| 3070|2022-07-01 20:51:57.051461|ADAPTIVE-SECONDARY > .
MasterDiagnostic _55160|ERR| 3071|2022-07-01 20:51:57.051476|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic _55160|WAR| 3072|2022-07-01 20:51:57.051488|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.

adsc_stop/start
  • flat 633 modes.

pupil wobbble check.

Fri Jul 1 20:57:34.285 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[122] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Chamber temperature: 16

bin1

  • ok
  • bin1_20220701.png

bin3

  • shutter 56.
  • pupil:20220119_035330
  • saturaiton before was from 90 to 0
  • it looks like a shift downward.
bin3_20220701.png

bin4

  • shutter 48
Fri Jul 1 20:57:34.285 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[122] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • pupil error<0.3 in the saturaion region 90 deg to 0 and 0 to 90
bin4-20220701.png

Stop 3:15PM

No Argos checks.

-- JuanCarlosGuerra - 01 Jul 2022
Topic revision: r2 - 02 Jul 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.