Details.

Power on

ocam ok

set flat

22-06-24 15:52:06.598277| MAIN > Maximum mode index used to apply flat -> # 634

Fri Jun 24 15:59:02.557 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[47] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:0,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 15:59:02.572 2022 aos.info - WFS source set to: FLAOWFS
Fri Jun 24 15:59:02.771 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Jun 24 15:59:04.095 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

preset mag 11

setup the filter 1 to r=90,t10

the psf is barely see in the tv

The AOS set a magnitude to zero.

the enter boxes can not be editable

restart AOS gui

24 16:22:54.369 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 16:22:54.382 2022 aos.info - WFS source set to: FLAOWFS
Fri Jun 24 16:22:54.399 2022 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[1] - Illegal command for state ManualAcquire

cancel preset from FLAO gui.

Fri Jun 24 16:23:30.122 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[2] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 16:23:30.136 2022 aos.info - WFS source set to: FLAOWFS
Fri Jun 24 16:23:30.194 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Jun 24 16:23:30.849 2022 aos.info - FLAO: WFS: loading setup for LUCIFER
Fri Jun 24 16:23:32.858 2022 aos.info - FLAO: WFS: configuring CCDs

shell rested..?

06-24 16:25:49.279751| MAIN > Maximum mode index used to apply flat -> # 634

283|2022-06-24 16:26:32.013481| MAIN > source_acq.acquire(): starting source acquisition
WfsArbitrator_177850|INF| 284|2022-06-24 16:26:32.015149| MAIN > Exception: thGetVar wfsarb.L.CLICK_ACQUIRE error(-3006): Variable not found error - Assuming automatic acquisition
WfsArbitrator_177850|INF| 285|2022-06-24 16:26:33.640658| MAIN > Star found at x=14.0, y=27.5, flux=17309.2
WfsArbitrator_177850|INF| 286|2022-06-24 16:26:33.642219| MAIN > source_acq.acquire(): star found at X=223.36,Y=439.79
WfsArbitrator_177850|INF| 287|2022-06-24 16:26:33.642276| MAIN > source_acq.acquire(): current error X=-2.067 mm, Y=0.517 mm
WfsArbitrator_177850|INF| 288|2022-06-24 16:26:41.669354| MAIN > Star found at x=28.6, y=31.1, flux=17120.8
WfsArbitrator_177850|INF| 289|2022-06-24 16:26:41.670731| MAIN > source_acq.acquire(): star found at X=457.86,Y=498.18
WfsArbitrator_177850|INF| 290|2022-06-24 16:26:41.670785| MAIN > source_acq.acquire(): current error X=-0.235 mm, Y=0.061 mm
WfsArbitrator_177850|INF| 291|2022-06-24 16:26:41.670810| MAIN > source_acq.acquire(): target reached.
WfsArbitrator_177850|INF| 292|2022-06-24 16:26:41.671817| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_177850|INF| 293|2022-06-24 16:26:41.832820| MAIN > WARNING: TTOffset LUT disabled due to issues with TT mirror offsets
WfsArbitrator_177850|DEB| 294|2022-06-24 16:26:41.833096| MAIN > arbFunc wrapper done.

[AOeng@soul-sxwfs source]$ use_soul
Usage: use_soul [version]
Currently running: stable (soul)
Available versions in /home/AOeng/soul:
latest
stable
stable.20211012
stable.20220131
test.20220304.aoice-default-ports
test.20220419.agw-power-wait-for-operating-rebase-onto-stable
test.20220602.setz0-ban

ocam not live...

interrupt the command live again...

restart the wfs masterdiagnostuc.

MasterDiagnostic _177748|WAR| 2908|2022-06-24 16:31:53.925880 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 921 (instead of packetId 0 for frameId 921)
MasterDiagnostic_177748|WAR| 2909|2022-06-24 16:31:53.925895 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_177748|WAR| 2910|2022-06-24 16:31:53.925937 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 921 (instead of packetId 0 for frameId 921)
MasterDiagnostic_177748|WAR| 2911|2022-06-24 16:31:53.925950 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_177748|WAR| 2912|2022-06-24 16:32:10.136528 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 0 for frameId 664 (instead of packetId 5 for frameId 659)
MasterDiagnostic_177748|WAR| 2913|2022-06-24 16:32:10.136588 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_177748|WAR| 2914|2022-06-24 16:32:10.136658 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 1 for frameId 664 (instead of packetId 0 for frameId 664)
MasterDiagnostic_177748|WAR| 2915|2022-06-24 16:32:10.136676 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_177748|WAR| 2916|2022-06-24 16:32:10.136733 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 2 for frameId 664 (instead of packetId 0 for frameId 664)
MasterDiagnostic_177748|WAR| 2917|2022-06-24 16:32:10.136749 BCU39 > FramesDownloader BCU39: packet successfully ignored !

cancel the preset.

Fri Jun 24 16:33:02.852 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[4] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 16:33:02.871 2022 aos.info - WFS source set to: FLAOWFS
Fri Jun 24 16:33:02.957 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Fri Jun 24 16:33:03.700 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

once close the loop the masterdiagnostic shows:

16:34:39.145934 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 330|2022-06-24 16:34:39.450759 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149D58 and 00000000
MasterDiagnostic_138731|WAR| 331|2022-06-24 16:34:39.450824 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 332|2022-06-24 16:34:39.536485 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149E20 and 00000000
MasterDiagnostic_138731|WAR| 333|2022-06-24 16:34:39.536548 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 334|2022-06-24 16:34:39.841326 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149E20 and 00000000
MasterDiagnostic_138731|WAR| 335|2022-06-24 16:34:39.841390 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 336|2022-06-24 16:34:40.146183 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149E20 and 00000000
MasterDiagnostic_138731|WAR| 337|2022-06-24 16:34:40.146250 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 338|2022-06-24 16:34:40.466498 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149E20 and 00000000
MasterDiagnostic_138731|WAR| 339|2022-06-24 16:34:40.466571 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 340|2022-06-24 16:34:40.536805 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149EE8 and 00000000
MasterDiagnostic_138731|WAR| 341|2022-06-24 16:34:40.536869 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 342|2022-06-24 16:34:40.841629 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149EE8 and 00000000
MasterDiagnostic_138731|WAR| 343|2022-06-24 16:34:40.841693 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 344|2022-06-24 16:34:41.146472 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149EE8 and 00000000
MasterDiagnostic_138731|WAR| 345|2022-06-24 16:34:41.146537 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 346|2022-06-24 16:34:41.451322 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149EE8 and 00000000
MasterDiagnostic_138731|WAR| 347|2022-06-24 16:34:41.451387 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 348|2022-06-24 16:34:41.535826 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149FB0 and 00000000
MasterDiagnostic_138731|WAR| 349|2022-06-24 16:34:41.535891 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 350|2022-06-24 16:34:41.840749 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149FB0 and 00000000
MasterDiagnostic_138731|WAR| 351|2022-06-24 16:34:41.840812 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 352|2022-06-24 16:34:42.150351 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149FB0 and 00000000
MasterDiagnostic_138731|WAR| 353|2022-06-24 16:34:42.150417 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 354|2022-06-24 16:34:42.461171 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00149FB0 and 00000000
MasterDiagnostic_138731|WAR| 355|2022-06-24 16:34:42.461236 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 356|2022-06-24 16:34:42.536246 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A078 and 00000000
MasterDiagnostic_138731|WAR| 357|2022-06-24 16:34:42.536308 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 358|2022-06-24 16:34:42.841035 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A078 and 00000000
MasterDiagnostic_138731|WAR| 359|2022-06-24 16:34:42.841079 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 360|2022-06-24 16:34:43.145861 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A078 and 00000000
MasterDiagnostic_138731|WAR| 361|2022-06-24 16:34:43.145924 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 362|2022-06-24 16:34:43.455564 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A078 and 00000000
MasterDiagnostic_138731|WAR| 363|2022-06-24 16:34:43.455635 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 364|2022-06-24 16:34:43.536483 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A140 and 00000000
MasterDiagnostic_138731|WAR| 365|2022-06-24 16:34:43.536546 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 366|2022-06-24 16:34:43.848451 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A140 and 00000000
MasterDiagnostic_138731|WAR| 367|2022-06-24 16:34:43.848526 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 368|2022-06-24 16:34:44.153346 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A140 and 00000000
MasterDiagnostic_138731|WAR| 369|2022-06-24 16:34:44.153412 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 370|2022-06-24 16:34:44.458172 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A140 and 00000000
MasterDiagnostic_138731|WAR| 371|2022-06-24 16:34:44.458240 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 372|2022-06-24 16:34:44.536783 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A208 and 00000000
MasterDiagnostic_138731|WAR| 373|2022-06-24 16:34:44.536843 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 374|2022-06-24 16:34:44.869045 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A208 and 00000000
MasterDiagnostic_138731|WAR| 375|2022-06-24 16:34:44.869109 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 376|2022-06-24 16:34:45.189393 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A208 and 00000000
MasterDiagnostic_138731|WAR| 377|2022-06-24 16:34:45.189458 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 378|2022-06-24 16:34:45.514481 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A208 and 00000000
MasterDiagnostic_138731|WAR| 379|2022-06-24 16:34:45.514545 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 380|2022-06-24 16:34:45.537118 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A2D0 and 00000000
MasterDiagnostic_138731|WAR| 381|2022-06-24 16:34:45.537180 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 382|2022-06-24 16:34:45.852711 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A2D0 and 00000000
MasterDiagnostic_138731|WAR| 383|2022-06-24 16:34:45.852775 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 384|2022-06-24 16:34:46.158737 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A2D0 and 00000000
MasterDiagnostic_138731|WAR| 385|2022-06-24 16:34:46.158803 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 386|2022-06-24 16:34:46.474318 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A2D0 and 00000000
MasterDiagnostic_138731|WAR| 387|2022-06-24 16:34:46.474390 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 388|2022-06-24 16:34:46.536249 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A398 and 00000000
MasterDiagnostic_138731|WAR| 389|2022-06-24 16:34:46.536312 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 390|2022-06-24 16:34:46.851810 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A398 and 00000000
MasterDiagnostic_138731|WAR| 391|2022-06-24 16:34:46.851873 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 392|2022-06-24 16:34:47.156596 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A398 and 00000000
MasterDiagnostic_138731|WAR| 393|2022-06-24 16:34:47.156661 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 394|2022-06-24 16:34:47.461482 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A398 and 00000000
MasterDiagnostic_138731|WAR| 395|2022-06-24 16:34:47.461539 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 396|2022-06-24 16:34:47.536484 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A460 and 00000000
MasterDiagnostic_138731|WAR| 397|2022-06-24 16:34:47.536538 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 398|2022-06-24 16:34:47.841415 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A460 and 00000000
MasterDiagnostic_138731|WAR| 399|2022-06-24 16:34:47.841488 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 400|2022-06-24 16:34:48.156999 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A460 and 00000000
MasterDiagnostic_138731|WAR| 401|2022-06-24 16:34:48.157074 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 402|2022-06-24 16:34:48.461815 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A460 and 00000000
MasterDiagnostic_138731|WAR| 403|2022-06-24 16:34:48.461880 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 404|2022-06-24 16:34:48.536806 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A528 and 00000000
MasterDiagnostic_138731|WAR| 405|2022-06-24 16:34:48.536869 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 406|2022-06-24 16:34:48.841715 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A528 and 00000000
MasterDiagnostic_138731|WAR| 407|2022-06-24 16:34:48.841781 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 408|2022-06-24 16:34:49.152503 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A528 and 00000000
MasterDiagnostic_138731|WAR| 409|2022-06-24 16:34:49.152568 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 410|2022-06-24 16:34:49.462524 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A528 and 00000000
MasterDiagnostic_138731|WAR| 411|2022-06-24 16:34:49.462596 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 412|2022-06-24 16:34:49.537147 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A5F0 and 00000000
MasterDiagnostic_138731|WAR| 413|2022-06-24 16:34:49.537211 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 414|2022-06-24 16:34:49.852711 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A5F0 and 00000000
MasterDiagnostic_138731|WAR| 415|2022-06-24 16:34:49.852771 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 416|2022-06-24 16:34:50.157584 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A5F0 and 00000000
MasterDiagnostic_138731|WAR| 417|2022-06-24 16:34:50.157649 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 418|2022-06-24 16:34:50.464785 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A5F0 and 00000000
MasterDiagnostic_138731|WAR| 419|2022-06-24 16:34:50.464849 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 420|2022-06-24 16:34:50.537423 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A6B8 and 00000000
MasterDiagnostic_138731|WAR| 421|2022-06-24 16:34:50.537494 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|ERR| 422|2022-06-24 16:34:50.848275 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 0014A6B8 and 00000000
MasterDiagnostic_138731|WAR| 423|2022-06-24 16:34:50.848338 OPTICAL-LOOP > Wrong filotto. Frame skipped.
MasterDiagnostic_138731|INF| 424|2022-06-24 16:34:50.892165 MAIN > Setting optical loop OPEN
MasterDiagnostic_138731|INF| 425|2022-06-24 16:34:50.892362 MAIN > Optical loop set to 0 ...
MasterDiagnostic_138731|WAR| 426|2022-06-24 16:34:55.554287 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 4 for frameId 79 (instead of packetId 5 for frameId 76)
MasterDiagnostic_138731|WAR| 427|2022-06-24 16:34:55.554336 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_138731|WAR| 428|2022-06-24 16:34:55.554395 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 5 for frameId 79 (instead of packetId 0 for frameId 79)
MasterDiagnostic_138731|WAR| 429|2022-06-24 16:34:55.554420 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_138731|WAR| 430|2022-06-24 16:34:55.554471 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 6 for frameId 79 (instead of packetId 0 for frameId 79)
MasterDiagnostic_138731|WAR| 431|2022-06-24 16:34:55.554506 BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_138731|WAR| 432|2022-06-24 16:34:55.554620 BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 7 for frameId 79 (instead of packetId 0 for frameId 79)
MasterDiagnostic_138731|WAR| 433|2022-06-24 16:34:55.554651 BCU39 > FramesDownloader BCU39: p

adsec masterdiagnostic:


MasterDiagnostic_136361|ERR| 1037|2022-06-24 16:36:04.027019ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 61c0 12f47fd
MasterDiagnostic_136361|ERR| 1037|2022-06-24 16:36:04.027019ADAPTIVE-SECONDARY > .
MasterDiagnostic_136361|ERR| 1038|2022-06-24 16:36:04.027035ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_136361|WAR| 1039|2022-06-24 16:36:04.027049ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_136361|ERR| 1040|2022-06-24 16:36:04.027595ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER bytes: 0 0 0
MasterDiagnostic_136361|ERR| 1040|2022-06-24 16:36:04.027595ADAPTIVE-SECONDARY > .
MasterDiagnostic_136361|ERR| 1041|2022-06-24 16:36:04.027620ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER bytes: 0 61c0 12f47fe
MasterDiagnostic_136361|ERR| 1041|2022-06-24 16:36:04.027620ADAPTIVE-SECONDARY > .
MasterDiagnostic_136361|ERR| 1042|2022-06-24 16:36:04.027637ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_136361|WAR| 1043|2022-06-24 16:36:04.027655ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.

9:38 am adsc_stop/start.

2022-06-24 16:40:23.106667| MAIN > Maximum mode index used to apply flat -> # 634

Fri Jun 24 16:40:58.290 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

TN:20220624_165236,_165414

the loop is visible the pattern of the mode30

gains seems too low.

ncpaon

_a ot of skip frame and open the loop.

force to open the loop


idl_2830 |INF| 633|2022-06-24 16:55:03.303716| MAIN > Commands out of safe range ID: # 35
idl_2830 |INF|

analysis of data...

_165414bad data..

Fri Jun 24 17:00:37.923 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[8] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 17:00:37.941 2022 aos.info - WFS source set to: FLAOWFS

move the camera lens to a better range..x=50,y=50

optimize gain

disturbance not running..

1.60,0.18,0.30

modal SR85%

For this one it seems more stable.. to be chekced..

stopAO

check pupils.

i Jun 24 17:10:03.287 2022 aos.Stop{FLAO}.complete - Stop{FLAO}[11]
Fri Jun 24 17:10:21.653 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[12] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

stop...

check the script didn;t work. Brandon fixed.the script didn;t command the rotators, the irc was not running in the obs3..

start wobble test

chmaber temp 17C

bin1

10:31

bin3

shutter 52

11:00am

bin4

11:18am

pupil:20211205_144238

bin2

Fri Jun 24 18:44:43.112 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[20] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter 56

pupil:20211125_011619

11:54am

close loop check

bin1

angle 360.

optimize

dist 1"

Fri Jun 24 18:44:43.112 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[20] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

optimize

2.87,0.76,0.62

rbitrator_2948|WAR| 1042|2022-06-24 19:28:29.236585| MAIN > Skip frame detected! (2.78% of frames skipped.)
AdSecArbitrator_2948|WAR| 1043|2022-06-24 19:28:30.319180| MAIN > Skip frame detected! (1.89% of frames skipped.)
AdSecArbitrator_2948|WAR| 1044|2022-06-24 19:28:31.381534| MAIN > Skip frame detected! (0.11% of frames skipped.)
AdSecArbitrator_2948|WAR| 1046|2022-06-24 19:28:33.535277| MAIN > Skip frame detected! (3.00% of frames skipped.)
AdSecArbitrator_2948|WAR| 1047|2022-06-24 19:28:34.541287| MAIN > Skip frame detected! (1.33% of frames skipped.)
AdSecArbitrator_2948|WAR| 1048|2022-06-24 19:28:36.647592| MAIN > Skip frame detected! (0.22% of frames skipped.)
AdSecArbitrator_2948|WAR| 1049|2022-06-24 19:28:37.652199| MAIN > Skip frame detected! (2.78% of frames skipped.)

TN:20220624_193008

apply gopt

_193116,_193454

modal SR:85

tn+luci

_193531, luic20220625.0001

ncpaon

skip frames

and loop open.totally software off. arbitrator off.Arbitrator down...

???

022-06-24 19:37:48.666280| MAIN > fsm_stop_ao start
idl_2830 |INF| 1383|2022-06-24 19:37:48.666372| MAIN > fsm_skip_recovery FORCE set
AdSecArbitrator_2948|INF| 1418|2022-06-24 19:37:48.665953| COMMANDHANDLER > FSM (status: AORunning) has received command 2015 (Stop Ao)
AdSecArbitrator_2948|INF| 1419|2022-06-24 19:37:48.665980| SERIALIZATION > StopAoImpl (): restoreShape = 1
idl_2830 |INF| 1384|2022-06-24 19:37:48.879178| MAIN > Null Gain application and start sending null slope...
idl_2830 |INF| 1385|2022-06-24 19:37:49.003980| MAIN > Cleaned last slopes command.
idl_2830 |INF| 1386|2022-06-24 19:37:49.004061| MAIN > Modes out of safe range ID: # -1
idl_2830 |INF| 1387|2022-06-24 19:37:49.004110| MAIN > Commands out of safe range ID: # 32 # 34 # 35 # 39
idl_2830 |INF| 1388|2022-06-24 19:37:49.004191| MAIN > Forces out of safe range ID: # 13 # 23 # 24 # 31 # 32 # 34 # 38 # 51 # 92 # 93 #101 #102 #103 #104 #106 #118 #122 #125 #132 #136 #138 #151 #152 #153 #156 #157 #164 #166
idl_2830 |INF| 1389|2022-06-24 19:37:49.004245| MAIN > SafeSkipFrames caused by commands out of range detected.
idl_2830 |INF| 1390|2022-06-24 19:37:49.004277| MAIN > SafeSkipFrames caused by forces out of range detected.
idl_2830 |INF| 1391|2022-06-24 19:37:49.004307| MAIN > Recovery from any SafeSkipFrames started...
idl_2830 |INF| 1392|2022-06-24 19:37:49.004339| MAIN > Getting info on actual mirror position...
idl_2830 |INF| 1393|2022-06-24 19:37:49.007828| MAIN > Reconstructor filter cleaning...
idl_2830 |INF| 1394|2022-06-24 19:37:49.013630| MAIN > Control current integrator cleaning up...
idl_2830 |INF| 1395|2022-06-24 19:37:49.032707| MAIN > Null new delta command contribution

rerotator 170.60

home-rot.

Fri Jun 24 19:42:50.990 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[29] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Jun 24 19

optimize

3.24,0.76,0.46

R| 191|2022-06-24 19:47:26.581377| MAIN > Skip frame detected! (3.11% of frames skipped.)
AdSecArbitrator_28032|WAR| 192|2022-06-24 19:47:27.587879| MAIN > Skip frame detected! (4.11% of frames skipped.)
AdSecArbitrator_28032|WAR| 193|2022-06-24 19:47:28.596349| MAIN > Skip frame detected! (5.89% of frames skipped.)
AdSecArbitrator_28032|WAR| 194|2022-06-24 19:47:29.603444| MAIN > Skip frame detected! (1.44% of frames skipped.)
AdSecArbitrator_28032|WAR| 195|2022-06-24 19:47:30.630887| MAIN > Skip frame detected! (3.22% of frames skipped.)
AdSecArbitrator_28032|WAR| 196|2022-06-24 19:47:31.646258| MAIN > Skip frame detected! (9.78% of frames skipped.)
AdSecArbitrator_28032|WAR| 197|2022-06-24 19:47:32.651941| MAIN > Skip frame detected! (3.56% of frames skipped.)

_194830

gopon

_195026

luci+tn:_195058

modal sr:85%

ncoaon

no skip frames

_195343

leave loop running for 1m

_195502

pause/resume

until next setGain command
AdSecArbitrator_28032|INF| 219|2022-06-24 19:56:21.673295| COMMANDHANDLER > Command Pause Ao (code 2027) successfully completed
20222406 19:56:45.0516 Alert: HighOrderOffl

28032|INF| 221|2022-06-24 19:56:54.945963| COMMANDHANDLER > FSM (status: AOPause) has received command 2028 (ResumeAo Ao)
AdSecArbitrator_28032|INF| 222|2022-06-24 19:56:54.953309| COMMANDHANDLER > Command ResumeAo Ao (code 2028) successfully completed
AdSecArbitrator_28032|INF| 223|2022-06-24 19:56:55.098231| MAIN > Received cmd: Offloading(1)

_195733

pause/resume

_200122

pause/resume

_200337

2022-06-24 20:03:21.904946| COMMANDHANDLER > Command TTOffload (code 2029) successfully completed
AdSecArbitrator_28032|INF| 256|2022-06-24 20:03:37.146871| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_28032|INF| 257|2022-06-24 20:03:37.243777| COMMANDHANDLER > Command Save status (code 2024) successfully completed
20222406 20:03:40.9457 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 258|2022-06-24 20:03:45.657449| MAIN > Skip frame detected! (0.11% of frames skipped.)
20222406 20:04:00.9746 Alert: HighOrderOffload: HighOrderOffload vector ready
20222406 20:04:21.0383 Alert: HighOrderOffload: HighOrderOffload vector ready
20222406 20:04:41.0531 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator _28032|WAR| 260|2022-06-24 20:04:44.592117| MAIN > Skip frame detected! (92.11% of frames skipped.)
AdSecArbitrator _28032|WAR| 261|2022-06-24 20:04:45.632022| MAIN > Skip frame detected! (106.89% of frames skipped.)
AdSecArbitrator _28032|WAR| 262|2022-06-24 20:04:45.632178| MAIN > Maximum skip frames reached: 106.89% of frames skipped. Will alert ICE clients.
AdSecArbitrator _28032|WAR| 263|2022-06-24 20:04:46.647866| MAIN > Skip frame detected! (109.00% of frames skipped.)
AdSecArbitrator_28032|WAR| 264|2022-06-24 20:04:46.648032| MAIN > Maximum skip frames reached: 109.00% of frames skipped. Will alert ICE clients.
AdSecArbitrator_28032|INF| 265|2022-06-24 20:04:46.651124| MAIN > Received cmd: StopAo (1)

loop open.

2830 |INF| 1520|2022-06-24 20:04:46.991803| MAIN > Modes out of safe range ID: # 59 #124
idl_2830 |INF| 1521|2022-06-24 20:04:46.991837| MAIN > Commands out of safe range ID: # -1
idl_2830 |INF| 1522|2022-06-24 20:04:46.991886| MAIN > Forces out of safe range ID: # 3 # 8 # 16 # 20 # 23 # 26 # 34 # 36 # 60 # 70 # 73 # 79 # 80 # 83 # 84 # 97 #100 #102 #104 #105 #107 #112 #119 #122 #125 #136 #137 #138 #139 #142 #147 #153 #154
idl_2830 |INF| 1523|2022-06-24 20:04:46.991906| MAIN > SafeSkipFrames caused by modes out of range detected.

camera lens moved everywhere....?

restart again

optimize

2.38,0.76,0.62

gopton

_201455

pause/resume

_201701

pause/resume

_201842

pause/resume

_202017

pause/resume

_202210

ncpaon

_202455

start to skip some percentage<1%

446|2022-06-24 20:25:01.018001| MAIN > Skip frame detected! (0.22% of frames skipped.)
20222406 20:25:07.6821 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 447|2022-06-24 20:25:24.025843| MAIN > Skip frame detected! (0.11% of frames skipped.)
20222406 20:25:27.7073 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 448|2022-06-24 20:25:28.648226| MAIN > Skip frame detected! (0.22% of frames skipped.)
AdSecArbitrator_28032|WAR| 449|2022-06-24 20:25:41.653439| MAIN > Skip frame detected! (0.11% of frames skipped.)
20222406 20:25:47.7355 Alert: HighOrderOffload: HighOrderOffload vector ready

pause/resume

_202650

pause/resume

_202852

started to skip frames before was not

481|2022-06-24 20:28:44.652652| MAIN > Skip frame detected! (0.78% of frames skipped.)
20222406 20:28:45.1258 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 482|2022-06-24 20:28:49.279832| MAIN > Skip frame detected! (1.00% of frames skipped.)
AdSecArbitrator_28032|INF| 483|2022-06-24 20:28:51.864031| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_28032|INF| 484|2022-06-24 20:28:51.957972| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_28032|WAR| 485|2022-06-24 20:28:53.661571| MAIN > Skip frame detected! (0.11% of frames skipped.)
AdSecArbitrator_28032|WAR| 486|2022-06-24 20:28:58.154099| MAIN > Skip frame detected! (1.00% of frames skipped.)
AdSecArbitrator_28032|WAR| 487|2022-06-24 20:29:03.638314| MAIN > Skip frame detected! (1.22% of frames skipped.)
20222406 20:29:05.1635 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 488|2022-06-24 20:29:12.270805| MAIN > Skip frame detected! (0.56% of frames skipped.)
20222406 20:29:25.1899 Alert: HighOrderOffload: HighOrderOffload vector ready

pause/resume

_203100

pause/resume

_203303

move rot to 180 deg

481|2022-06-24 20:28:44.652652| MAIN > Skip frame detected! (0.78% of frames skipped.)
20222406 20:28:45.1258 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 482|2022-06-24 20:28:49.279832| MAIN > Skip frame detected! (1.00% of frames skipped.)
AdSecArbitrator_28032|INF| 483|2022-06-24 20:28:51.864031| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_28032|INF| 484|2022-06-24 20:28:51.957972| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_28032|WAR| 485|2022-06-24 20:28:53.661571| MAIN > Skip frame detected! (0.11% of frames skipped.)
AdSecArbitrator_28032|WAR| 486|2022-06-24 20:28:58.154099| MAIN > Skip frame detected! (1.00% of frames skipped.)
AdSecArbitrator_28032|WAR| 487|2022-06-24 20:29:03.638314| MAIN > Skip frame detected! (1.22% of frames skipped.)
20222406 20:29:05.1635 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_28032|WAR| 488|2022-06-24 20:29:12.270805| MAIN > Skip frame detected! (0.56% of frames skipped.)
20222406 20:29:25.1899 Alert: HighOrderOffload: HighOrderOffload vector ready

optimize

a lot of skip frames duringth optimize

3.68,0.84,0.59

gopton

_204304

ncpaon

_204653

pause/resume

_204833

skip frames 1%

pause/resume

_205012

not saving..?

AdSecArbitrator _28032|WAR| 926|2022-06-24 20:51:14.876990| MAIN > Skip frame detected! (1.22% of frames skipped.)
AdSecArbitrator _28032|WAR| 927|2022-06-24 20:51:15.924111| MAIN > Skip frame detected! (1.89% of frames skipped.)
AdSecArbitrator _28032|ERR| 928|2022-06-24 20:51:21.646218| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator _28032|ERR| 929|2022-06-24 20:51:21.646256| ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20222406 20:51:21.6471 Alert: Error: COILS DISABLED
AdSecArbitrator _28032|INF| 930|2022-06-24 20:51:21.696943| ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2022/06/24/ADAPTIVE-SECONDARY_00001656103881_20220624_205121.bin
AdSecArbitrator _28032|INF| 931|2022-06-24 20:51:21.696983| ALERTHANDLER > Processdump is skipped
20222406 20:51:21.6977 Alert: DumpSaved: DumpSaved vector ready

dtop.

an actuator foun out of range DSP150

called Guido and Doiug

- JuanCarlosGuerra - 24 Jun 2022
Topic revision: r2 - 25 Jun 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.