power on
  • ok
ocam
  • not live.
  • The masterdiagnostic process is up.
MasterDiagnostic_137677|WAR| 583|2022-06-11 17:16:52.358182 BCU39 > .
MasterDiagnostic_137677|WAR| 584|2022-06-11 17:16:52.358198 BCU39 > FramesDownloader BCU39: UNEXPECTED BCU FRAME SIZE: 8836. instad of 2860
MasterDiagnostic_137677|WAR| 585|2022-06-11 17:16:52.358207 BCU39 > FramesDownloader BCU39: frame % successfully discarded %ENDCOLOR%
MasterDiagnostic_137677|WAR| 585|2022-06-11 17:16:52.358207 BCU39 > .
  • restart buc2k didn;t resolve the problem.
  • Restart the masterdiagnostic process, solved....

argos cal unit not moving.

argoscalunit_20220611.png

CRE DX was down,

Once it is up the enable conditons went to fullfilled.

The shutter of the whgite source seems not controlled.

Checking.

the psf is very bright.

it is useful for the pupil check

preset

Sat Jun 11 18:54:12.031 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[757] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Sat Jun 11 18:54:12.049 2022 aos.info - WFS source set to: FLAOWFS

Bin1 check pupil

12:05PM

stop the loop.

change direction for the pupil shift. move to +2

>>> makePupils.movePupils('20211210_210322',0,2,240,2)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_193929/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_193929/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 1256
out_of_pupil_slopes 336
lines_to_add 2
residual_pixels_to_add 24
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_193929
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_193929"
'20220611_193929'
>>>

test but it shows a large jump going forward...(????)

forward_jump20220611.png

shifted offbin1 y from 5 to 6

@341: CL x=36,Y=73

start wobble.1:25pm

backward

Y axis:OK.

X requires one step down. (possible, the error <0.15)

testing.....

>>> makePupils.movePupils('20211210_210322',-1,2,240,2)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_204439/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_204439/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 1256
out_of_pupil_slopes 336
lines_to_add 2
residual_pixels_to_add 24
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_204439
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220611_204439"
'20220611_204439'
>>>

change offbin1 x from 5 to 4

load the pupil.

1:50 PM wobble check

pupil seems good.

bin_shift_20220611.png

CONFIRM THE SHUTTER COMMAND OF THE WHITE SOURCE DOES'NT WORK.

change AO table for Bin1 new pupil and test.

BIN3 AND BIN4 CHECKED MANUALLY.

The filter 1 moved to T0.1

bin4 200Hz

EMgain300

4.5 420 3 900 600 KL_v20 20200922_150000 iir1000HzV004 20220119_035330 3 4 1 0 1 16 12.6 20 300
200 600 30 20e-9 80.0
15.5 167 3 750 600 KL_v20 20200922_150000 iir1000HzV004 20220119_035330 3 4 1 0 1 16 12.6 50 300
200 600 30 20e-9 80.0
15.5 167 3 750 600 KL_v20 20200922_150000 iir0750HzV002 20220119_035330 3 4 1 0 1 16 12.6 50 300
200 600 30 20e-9 80.0
15.8 135 3 500 600 KL_v20 20200922_150000 iir0750HzV002 20220119_035330 3 4 1 0 1 16 12.6 50 300
200 600 30 20e-9 80.0
15.8 135 3 500 600 KL_v20 20200922_153500 forgettingFactorBin4SOUL 20220119_035330 3 4 1 0 1 16 12.6 50 100
200 600 30 20e-9 80.0
16.5 67 3 250 600 KL_v20 20200922_153500 forgettingFactorBin4SOUL 20220119_035330 3 4 1 0 1 16 12.6 50 100
200 600 30 30e-9 80.0
16.5 67 4 500 600 KL_v20 20200923_180000 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 100
200 600 30 30e-9 45.0
17.1 38.3 4 285 600 KL_v20 20200923_180000 forgettingFactorBin4SOUL 20211205_144238 3 4 1 0 1 16 12.6 50 100
200 600 30 30e-9 45.0
17.5 26.5 4 190 600 KL_v20 20200923_180000 forgettingFactorBin4SOUL 20211205_144238

Bin4

shift one spte down in Y

NameError: name 'makePupil' is not defined
>>> makePupils.movePupils('20211205_144238',0,1,240,5)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212553/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212553/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212553
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212553"
'20220611_212553

Check

mistake, move in X

>>> makePupils.movePupils('20211205_144238',-1,0,240,5)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212913/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212913/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 80
out_of_pupil_slopes 2688
lines_to_add 12
residual_pixels_to_add 12
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212913
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode5/20220611_212913"
'20220611_212913'
>>>

Check

close loop-> CL, x=78,y=-20

check wobble

2:32PM

too much one step down in X

3:30 PM Stop.

keep troubleshooting the white source shutter issue.

remote power and manual commands send to the white source and it responds, the shutter is not responding. after a few tries a reset of the Moxa dn the device bright back the control of the shutter.

Ready for tomorrow.

-- JuanCarlosGuerra - 11 Jun 2022
Topic revision: r3 - 12 Jun 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback