Power on
  • ok
ocam
  • ok.

Wed Jun 8 16:24:49.042 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[641] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Jun 8 16:24:

hexapod:

2.38,1.34,-1.57,150,-190

Center pupil.

camera lens at the edge +100,-100. not moving back.

move manually to a position:52,86, process finish the acquistion ok

chamber temp:14C

BIN1 ROT.

bin1_20220608.png

BIN2 ROT

bin2-20220608.png
  • ed Jun 8 16:53:52.476 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[643] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:13,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
  • SHUTTER 56

BIN3 ROT

Wed Jun 8 17:16:13.371 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[645] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

shutter 56

BIN3_20220608.png

BIN4 ROT

Wed Jun 8 17:39:20.143 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[647] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

SHUTTER:52

BIN4_20220608.png

CLOSE LOOP

BIN1

Wed Jun 8 18:11:52.333 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[649] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Wed Jun 8 18:11:52.353 2022 aos.info - WFS source set to: FLAOWFS
Wed Jun 8 18:11:52.418 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits

2.93,0.5,0.3

GOPT->0.443

185715,

ncpaon

gopt->0.45

_190000,_190109

ncpaoff.

optimize gain

2.49,0.47,0.44

optimizegain_20220608.png

tn:_190716

ncpaon

modalplot_optimize_ncpaon.png

camera lens not on target

it reaches x +100

_190941

ncpa off

cameralens in target, move to 98.96

_191425

ncpaon

CLx:100 not in target

skip frames

_191638

ncpaoff

clx 97.7

_191918

apply gopt

SR->90%

_191257

ncpaon

not in target

SR>90%

_192348

ncpa on

_192520

12:30 PM STOP

19:35:57.840300| WFS > Executing setSafe...

19:36:11.781089| COMMANDHANDLER > Command setSafe (code 2043) successfully completed

During the process of making a new pupil mask, ther was a" power bump", the wfsarb reported at:

20:57:27.221689| MAIN > Processing alert 4003 (Cooling State Error) from ocam2.L: OCAM

PUPIL SHIFT.

>>> makePupils.movePupils('20211210_210322',0,-1,240,2)
makePupils_fromMasks(): moving from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220608_202845/pupdata.txt
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pupdata.txt" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220608_202845/pupdata.txt"
num_slopes 2848
len(pupi_list[0]) 1256
out_of_pupil_slopes 336
lines_to_add 2
residual_pixels_to_add 24
Entering main loop
Out of main loop
makePupils_common: moving fits file from /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2 to /home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220608_202845
/bin/mv -f "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/pup1.fits" "/home/AOeng/live/aoroot/calib/wfs/current/ocam2/LUTs/mode2/20220608_202845"
'20220608_202845