Staff:

LBTO:Juan Carlos

Arcetri: Enrico et al. Remote

Details

Issue with the Authorization of M3.

Problem solved and telescope released at 8:40AM

  • flat 630modes.
dx_flat_20220606.png

test preset.

Mon Jun 6 16:04:03.986 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[3082] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Jun 6 16:04:04.002 2022 aos.info - WFS source set to: LBTIWFS
Mon Jun 6 16:04:04.115 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq900.00_sd3892.fits
Mon Jun 6 16:04:04.969 2022 aos.info - FLAO: WFS: loading setup for LBTI

Source not in the CCD47

spiral search (300e-6,15)

hexapod position:

Close loop using the eng gui.
  • freq 200,10l/D,emgain=300
  • 20220606_173536
Analysis of the pupil illumination; Arcetri working on with the data.
  • _174543
closeloop_10modi20220606.png

close loop
  • _175738
  • open loop.
  • load default flat.
  • close loop
  • _181035
save flat.

Arbitrator_61042|INF| 430|2022-06-06 18:14:37.336488| MAIN > Received cmd: SaveShape("default_20220606_300m.sav)
AdSecArbitrator_61042|INF| 431|2022-06-06 18:14:37.336563| COMMANDHANDLER > FSM (status: AORunning) has received command 2021 (Save shape)
AdSecArbitrator_61042|INF| 432|2022-06-06 18:14:47.877972| COMMANDHANDLER > Command Save shape (code 2021) successfully completed

Acquire a new inmat with the flat saved.

default_20220606_300m.sav

acquire a second inmat with large number of iterations:6

acquireInMat_lbti_20220606.png

new inmat: 20220606_183610

/local/aomeas/adsec_calib/M2C/KL_v28/gain/g_tt_0.10_ho1_0.05_ho2_0.05.fits

dxwunit 27397 25084 0 18:25 pts/1 00:00:04 /usr/local/itt/idl71/bin/bin.linux.x86_64/idl -e gen_intmat_gui, PATH_PREFIX='/local/aomeas/adsec_calib/', INTMAT_ACQ_DIR='M2C/KL_v29/intmatAcq/20220606_182339', OUTPUT_FILE='M2C/KL_v29/RECs/Intmat_20220606_182539.fits', SKIP_FRAME=2, AVG_FRAME=2, SIG_CHECK=0, REMOVE_TILT=1, /INTERACTIVE

new inmat_184615

close loop from EngGui

_185721<_185829

save a flat:default_20220606_500m.sav

check close loop.

_191138

Acquire new Inmtat.

06-06 19:10:28.352297| MAIN > The disturbance command application is still enabled. Please stop it and retry.

Acquire INMAT error.

  • If the disturbance is not loaded, check for the adsec IDL log.. it seems that the first time the disturbance was loaded and running and it can not apply a second time.
  • Load a flat. just to clean up the IDL commands.
New Inmat
  • change to 400Hz.
  • iterations=6
  • Inmat:20220606_192212
close check

Rec:KL_29 202200606_
  • 400freq.
  • _194028
aos preset.

Mon Jun 6 19:49:30.868 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[3089] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Jun 6 19:49:30.887 2022 aos.info - WFS source set to: LBTIWFS
Mon Jun 6 19:49:30.923 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.2_L040.0_v15.0_ovfreq900.00_sd3892.fits
Mon Jun 6 19:49:31.515 2022 aos.info - FLAO: WFS: loading setup for LBTI

Mon Jun 6 19:57:56.861 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[3091] (aomode:ACE-AO,focst:bentGregorianCenter,instr:LBTI,wfs:LBTIWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:10.2,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Mon Jun 6 19:57:56.876 2022 aos.info - WFS source set to: LBTIWFS
Mon Jun 6 19:57:56.920 2022 aos.info - FLAO: WARNING: added atmospheri

close loop
  • distu on seeing 1.2
  • _200615,_200649,_200727,_200749,_200806,_200824,_200852

saving TN:

_201915,_201939,_202000,_202141,_202202,_202221,_202239

Gopt apply:

202238,_202456,_202521,_202535,_205555,_202618,_202632,_202656,_202711,_202737,_202737,_202834,_202949,_203023,_203050,_203136,

stop 1:35PM

-- JuanCarlosGuerra - 06 Jun 2022
Topic revision: r1 - 06 Jun 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback