Details.

Power on.
  • OK
camera lens
  • not live.
  • Power cycle bcu2k+restore setup ok
  • frames:20220524_155800
  • one quadrant more illuminated.
  • taking a dark
  • TN:_160426
  • flat: 635
TEST PRESET

Tue May 24 16:06:12.532 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[4000] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

MOVE CAMERA LENS BY HAND.
  • CL X=28 y=64 @341
  • CHAMBER TEMPERATURE 5.8

BIN 1 WOBBLE

START 9:19AM

BIN2 WOBBLE.

START 9:50AM

SHUTTER 60 MAG 12.5

BIN3 WOBBLE

  • shutter 55 mag 14.2
  • switch bin 3 to bin1
  • ok.
  • start 10:19am

BIN4 WOBBLE.

bin4_20220522.png

bin4 to bin3

oca_viewer_b4tob3.png
  • Star not visible.
  • launch another preset, the PSF is visible....
  • Check positons of the FW1

Repeat Bin3 wobble

ok

close loop check

shutter 45 mag 16.5

bin3 faint

freq 291.

3.35,1.7,0.10

gopt->0.19

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 19:06:25.532 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 19:06:25.591 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits
  • luci setup for J
  • optimize gain:
  • 4,2,0.1
  • gopt->0.14
  • skipframes.
  • 20220524_191651. luci 0030
bin3_faint200Hz_dist1arcsec.png
  • dark luci:20220525.0040
  • _192155, luci 0050
  • 5 frames.
  • _192425
  • SR->0.02
  • dark->0071
move to mag 16.51 for bijn4 bright.

}[4027] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.53,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 19:31:57.461 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 19:31:57.520 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits

bin4

482Hz

optimize
  • 1.26,0.99,0.10
  • _193626
  • SR->0.02
  • gopt->0.15
  • _193919
  • start to skip frames.
  • increase gopt gain to tt 0.29
  • _194202
  • optimize gain
  • 1.21,0.89,0.1
  • gopt ->0.14
  • _194644
  • stop gopt
  • _194937

skip frames scenario with 10modi

save files:_195232

stopAO

"/home/aoeng/live/aoroot/lib/python/statemap.py", line 104, in getState raise StateUndefinedExceptionStateUndefinedException
Tue May 24 19:29:36.426 2022 aos.Stop{FLAO}.complete - Stop{FLAO}[4026]
Tue May 24 19:31:57.449 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[4027] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.53,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 19:31:57.461 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 19:31:57.520 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits
  • optimize
  • 1.56,0.71,0.56
  • _200204
  • gopt->0.5
  • _200544
  • remove the second pass for HO1 and HO2
  • optimize
  • 2.37,0.76,0.63
  • _
  • skip frames for ho2
  • save before to apply gopt. increse frames to 10000
  • _201149
  • gopt->0.49
  • _201457
  • not tracking GOPT
  • optimizse
  • 1.96,0.84,0.57
  • _201848
  • gopt->0.49
  • _202340

Change for bin1 autogain two skip the second pass
  • frequency 0->400 used for TTM mode.
AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 20:28:54.626 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 20:28:54.764 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits
  • optimize
  • 2.2,1.91,0.09
  • _203453,_203706
  • set mode to50
  • optimize
  • doen;t work-> back to cut 120
  • ho1 too high ->13.
  • reduce the ho1 amx to 6 and ho2->3
  • optimize
  • 4.17,9,0.09
  • _204657
stopAO

same preset.

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 20:51:29.718 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 20:51:29.777 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits

1:53 PM

hexapod issue.

call Mike Gardiner

20220524_leg4.png

2:02

restart

Preset.
  • optimize
  • the second pass is commented. and ho1 max ->6 ho2->3
  • 2.33,6.53,0.09
  • _210903
  • optimize_tt_bin1.png
  • optimize
  • second time shows a higher TT
  • 10.80,6.34,0.09
  • _211309
  • activate second pass for ho1
  • optimize
  • optimize_bin1_secondtry.png
  • Activate the second pass
  • optimize
  • 5.61,5.4,0.09
  • _211658
optimize_tt_bin1_2passesfro ho1.png

default passes

optimize

5.61,6.53,0.08

_212141

default conf

scan too far for ho1

3.54,12.26,0.08

_212648

optimize_ttt_bin1_default.png

Check Bin1 ACE

Tue May 24 21:29:49.360 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[4040] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 24 21:29:49.377 2022 aos.info - WFS source set to: FLAOWFS
Tue May 24 21:29:49.437 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
  • optimize
  • 2.7,0.59,0.57
  • gopt->0.48
  • _213826
  • SR73
  • psf_bin1_ncpaoff0p8.png

  • ncapon
bin1_iotimize_dis0p8.png
  • saving before apply ncpa
  • _214030
  • ncpa on and it is n ot shown in the gopt gui ->trigger not activate
  • second try
  • activated from gui and activate the trigger...
  • start to save before to activate the trigger
  • _214244
  • ncpa off
  • saving ncpa off->ncpa on->ncpa off

saving data at the same time seems.tha tthe ncpa is not applying the coeff

a way to unsync with the gopt..?

  • optimcal loop finished and it doen'rt show the values.
  • ncpa on
  • _214926
  • ncpaoff
  • _215150
  • ncpa off/on during acq
  • ncpa on
  • _215416
  • sr->0.8
  • bin_ncpaon_20220524_0p8.png

3PM STOPAO

-- JuanCarlosGuerra - 24 May 2022
Topic revision: r2 - 24 May 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.