1:10 Power up SX LUCI SOUL WFS

7:51 Adsec Failure at end of LBTI operations

MD TIMEOUT CA *****
MirrorCtrl _106542  |ERR|       773|2022-05-14 07:51:15.223768| 
BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuRep
ly: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       774|2022-05-14 07:51:16.239255|             MAIN >  ***** FAILED PACKET FROM BCU 2 - C
MD TIMEOUT CA *****
MirrorCtrl _106542  |ERR|       775|2022-05-14 07:51:16.239314| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuRep
ly: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       776|2022-05-14 07:51:17.256177|             MAIN >  ***** FAILED PACKET FROM BCU 2 - C
MD TIMEOUT CA  *****
MirrorCtrl _106542  |ERR|       777|2022-05-14 07:51:17.256228| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuRep
ly: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       778|2022-05-14 07:51:18.271626|             MAIN >  ***** FAILED PACKET FROM BCU 2 - C
MD TIMEOUT CA  *****
MirrorCtrl _106542  |ERR|       779|2022-05-14 07:51:18.271669| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuRep
ly: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       780|2022-05-14 07:51:19.287278|             MAIN >  ***** FAILED PACKET FROM BCU 2 - C
MD TIMEOUT CA  *****
MirrorCtrl _106542  |ERR|       781|2022-05-14 07:51:19.287339| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuRep
ly: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       782|2022-05-14 07:51:20.302231|             MAIN >  ***** FAILED PACKET FROM BCU 2 - C
MD TIMEOUT CA *****
MirrorCtrl _106542  |ERR|       783|2022-05-14 07:51:20.302290| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       784|2022-05-14 07:51:21.318017|             MAIN >  ***** FAILED PACKET FROM BCU 2 - CMD TIMEOUT CA  *****
MirrorCtrl _106542  |ERR|       785|2022-05-14 07:51:21.318069| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(
MirrorCtrl _106542  |ERR|       786|2022-05-14 07:51:22.336299|             MAIN >  ***** FAILED PACKET FROM BCU 2 - CMD TIMEOUT CA  *****
MirrorCtrl _106542  |ERR|       787|2022-05-14 07:51:22.336364| BCUCOMMANDHANDLER_2_P3 > BcuCommandHandler::handleBcuReply: REQUEST COMPLETED but FAILED :-(
adamhousekeeper.L  |INF|     19796|2022-05-14 07:52:09.266384|  AdamTCSSysFault > 1

7:55 Noted noise on OCAM (but forgot the recording & TN sorry), rebinned and cooled.

8:17 Preset to First LUCI TTM target, testing faint end
  • Seeing 0.89"
  • Catalog 16.7 mag target, Estimated OCAM mag is 17.6
  • Closed, bin4 freq 191, mod 3, EM gain, Nmodes 13
  • tt 0.81, 0.30, 0.10
  • TN 082451, 082830, 083527
  • 0.42" on LUCI1 ESM vs 0.66" on LUCI2 SL
8:36 Preset to next faint test number 2 for TTM
  • Seeing 0.87" on the DIMM, 0.61" on the Guider
  • Catalog R mag 17.1,
  • Closed with bin4 153 Hz, mod 3 EM gain 600, Nmodes 13
  • Estimated 18.0 OCAM mag
  • <7min from preset to loop closed on an 18th mag.... not bad, could be better wink
  • tt 0.79, ho1 0.73, h02 0.1
  • TN 084617, TN 084936
  • 2.6 photons/subapp, slope rms ~0.94, ~15 counts average pupils intensity
8:57 Preset to third and last faint test for EMS. This target is a QSO.
  • Catalog Rmag 17.0
  • Seeing 1.08" on the DIMM
  • 2.4 photons/subapp, ~11 counts average pupil intensity, 0.97 slop e rms
  • Estimated OCAM mag 18.3
  • Closed with tt 0.96, ho1 0.75, ho2 0.1
  • Bin4, freq 124, mod3, EM gain 600, Nmodes 13
  • TN 090726, 091104, 091815
  • 0.42 on luci1, 0.52 on luci2
  • Sky offset 1.5photons/subapp while the source 2.4 photons/subapp
9:19 Preset to Ring Nebula
  • Catalog Rmag 12.2
  • Sent as bin 1 but star is closer to 14th. Manually centered up puils and checked flux to force to bin2.
  • bin2, freq 400, mod3, EM gain 600, Nmodes 12
  • OCAM estimated mag 14.2
  • DIMM seeing 0.97"
  • tt 2.2, ho1 6.03, ho2 0.08
  • TN 093359, 095046, 102409
  • 0.38" on luci1, 0.45 on luci2. Seeing is just too good.
  • 10:07 Seeing deteriorating ~1.4-1.9" on the DIMM, and ESM is making a more notable difference: 0.58 on luci1, 0.87 on luci2
10:25 Preset to Barry's super fun and super bright subwindowing target: intermediate redshift galazy with a bright bin 1 ESM star near it
  • Catalog magnitude R 7.3
  • Center star clained success on first click but did not move the star
  • OCAM mag 8.9
  • Dimm seeing 1.11"
  • Bin 1, 600 Hz, modulation3, EM gain 326, 12 modes. Why does it ramp ho2 when optimizing for ESM? IT 8636
  • Closed with gains tt 10.8, ho1 10.88, ho2 0.08
  • Slope RMS 0.59, 121 photons/subapp, ~330 counts average pupil intensity
  • TN104538,
  • 0.43" on luci1 and 0.66" on luci2
11:36 All done. StopAO and closeing up. Set Safe state for the WFS.

11:45 DX rested has a gap of 36.37 when rested at actuator 263 (not the 46 we saw yesterday so good enough.

Powering off WFS

-- JenniferPower - 14 May 2022
Topic revision: r2 - 14 May 2022, JenniferPower
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback