20220510_DX_Day_2 DX S-LUCI Set_Z0 test, Day 2

9:45 Starting
  • w_stop OK
  • w_check Ok
  • w_start Housekeeper did not start
  • w_stop OK
  • w_check OK
  • w_start OK

9:56 Operate
  • 10:04 Done

10:13 Authorize LFBG

10:20 AcquireRef
  • bin 1 200 Hz
  • OCAM not live
    • No communication to BCU bos
  • Interrupt
  • WFS Control GUI set params to bin 2
    • Reading shared buffer master diagnostic...error box
  • stop/start slope computer
  • WFS Control GUI set params to bin 1
    • Reading shared buffer master diagnostic...error box
  • stop/start OCAM 2k controller
  • WFS Control GUI set params to bin 1
    • Reading shared buffer master diagnostic...error box
    • MasterDiagnostic_102388|WAR| 10485|2022-05-11 17:21:41.973471 OPTICAL-LOOP > Wrong filotto. Frame skipped.
    • MasterDiagnostic_102388|ERR| 10486|2022-05-11 17:21:42.278337 OPTICAL-LOOP > Rejected wrong filotto between WFS and AdSec: 00000000 and 0028FFB9
  • stop/start Masterdiagnostics process
    • Reading shared buffer master diagnostic...error box
  • stop/start Master, OCAM 2k and Slope computer
    • Reading shared buffer master diagnostic...error box
  • Power cycle BCU2k
  • WFS Control GUI set params to bin 2
    • Reading shared buffer master diagnostic...error box

10:35 w_stop_all/start_all
  • OCAM not live on startup
  • PresetAO OK, OCAM live
  • AcquireRef
    • HO1 gains applied manually
  • Closed loop
  • Optimize gain
  • Done, startao
  • bin 1, 900 Hz

10:45 Force Open Loop Button
  • WFS Control GUI set bin 1, 1200 Hz
  • Re-Close Loop
  • Optimize Gain.
    • Skipframe and open loop 3 times
    • Tried to set manually but skip frame and open loop
    • Re-close loop
  • Preset, acquireRef and skipframe, open loop with bin 1 1200 Hz

11:05 Change AO table to have 1200 Hz

11:05 AdSec went into failure during Center Pupils
DLER > Processdump is skipped
20221105 18:07:30.2485 Alert: DumpSaved: DumpSaved vector ready
AdSecArbitrator_12850|ERR|      3457|2022-05-11 18:07:32.707892|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_12850|ERR|      3458|2022-05-11 18:07:32.707944|     ALERTHANDLER > Alert message: COILS DISABLED from fastdiagn.L
20221105 18:07:32.7089 Alert: Error: COILS DISABLED
AdSecArbitrator_12850|WAR|      3459|2022-05-11 18:07:32.708430|             MAIN > Cannot dispatch alert "Error" to /adsecarb.L: ConnectionI.cpp:2924: Ice::CloseConnectionException:
AdSecArbitrator_12850|WAR|      3459|2022-05-11 18:07:32.708430|             MAIN >  . protocol error: connection closed
AdSecArbitrator_12850|INF|      3460|2022-05-11 18:07:32.777359|     ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2022/05/11/ADAPTIVE-SECONDARY_00001652292452_20220511_180732.bin
AdSecArbitrator_12850|INF|      3461|2022-05-11 18:07:32.777397|     ALERTHANDLER > Processdump is skipped
20221105 18:07:32.7784 Alert: DumpSaved: DumpSaved vector ready
AdSecArbitrator_12850|ERR|      3462|2022-05-11 18:07:36.779860|     ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator_12850|ERR|      3463|2022-05-11 18:07:36.779954|     ALERTHANDLER > Alert message: COILS DISABLED from f

11:15 SX AdSec Restarted and Set
  • Stop/Start WFS Arbitrator (just to be sure it's connected properly)

11:15 PresetAO

11:30 Ran python run_ncpa.py --count 720 --delay 5 --bank 0
  • Loop opened
  • NCPA coefficients where E-5, need E-9
  • Edited run_npca.py to have:
    • z0_values = [0,0,0, 15.7E-9, 59.7E-9, -19.6E-9, 6.63E-9, -0.41E-9, -8.84E-9, 13E-9, -11.2E-9]
  • ncpa images:
    ncpa_pupils.jpg ncpa_values.jpg

11:42 Preset and Acquire in Auto Mode

11:47 Start run_ncpa.py script

12:52 No Failure

12:52 python run_ncpa.py --count 720 --delay 3 --bank 0
  • 01:25 No Failures after 558 set_z0's
  • Need to handover to the mountain so they can look at LUCI1 focus problem

1:40 Done. Both CalUnits park, everything off

  • Movie of SX Closed Loop, no disturbance. The no-current actuators can be seen at 9:30
  • ocam_edge.mov: ocam_edge.mov

  • bin3_pupil_count.jpg: From Nighttime, 20220511 UT. ~17 counts be sub app seems too low.
    bin3_pupil_count.jpg

-- DougMiller - 11 May 2022
I Attachment Action Size Date Who Comment
bin3_pupil_count.jpgjpg bin3_pupil_count.jpg manage 128 K 11 May 2022 - 20:50 DougMiller  
ncpa_pupils.jpgjpg ncpa_pupils.jpg manage 49 K 11 May 2022 - 20:49 DougMiller  
ncpa_values.jpgjpg ncpa_values.jpg manage 32 K 11 May 2022 - 20:49 DougMiller  
ocam_edge.movmov ocam_edge.mov manage 1 MB 11 May 2022 - 20:50 DougMiller  
Topic revision: r2 - 11 May 2022, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback