20220505_DX_Day. LBTI AO, Day 3

15:13 UT current chamber temperature 4.3C

15:53: UT current chamber temperature 4.8C, waiting for confirmation from monutain

15:59 UT restarting DX ASM in daytime configuration

16:02 UT ASM set with Maximum mode 631 RB temperature 3.7C small bump at 565 (force +0.17)

16:05 UT loading 20220504_154450/Ref_2C_flat.sav (565 force +0.05, 114 force +0.07, 367 +0.06) RB temperature 3.6C

17:21 UT bumping act 552 (force +0.15) (it looks like the AO loop tends to increase the force on this actuator)
  • AdOpt>print,v=gauss_comm(552,1.0)
  • AdOpt>v=gauss_comm(552,1.0)
  • AdOpt>v1=50e-9*v
  • AdOpt>print,fsm_apply_cmd(v1,/delta,/passed)
  • + 50e-9 force +0.07
  • + 50e-9 force -0.02
  • flat saved as: /local/aomeas/adsec_calib/flat/Applicable/XianyusFavoriteFlat.sav

18:37 UT we could not generate the disturbance files, but following the instructions below we did generate some files
  • AOeng@dxadsec ~]$ export ADOPT_ELAB=/home/aoeng/aoroot/idl/elab_lib
  • [AOeng@dxadsec ~]$ export ADOPT_PHASEMAPS=/local/phase_maps
  • [AOeng@dxadsec atm_disturb]$ mkdir /local/aomeas/adsec_calib/M2C/KL_v28/atm_disturb
  • [AOeng@dxadsec ~]$ idl
  • AO> @/home/aoeng/aoroot/idl/elab_lib/batch_generate_disturb_doug

-- GuidoBrusa - 05 May 2022