Details.

power on

the system has the new power on file loaded.

set flat.

Adsec IDL controllwer down.

start the process.

adsc_stop/start.

flat#635

test preset.

OK

optimize gain wo disturbance.

optmize_bin1_wodist.png

r_76538|INF| 475|2022-05-03 17:36:10.963891| MAIN > Total counts/subap: 2213.255803 - framerate: 200.0 - Flux: 27040
WfsArbitrator_76538|DEB| 476|2022-05-03 17:36:10.964793| MAIN > Estimated magnitude from camera: 9.98
WfsArbitrator_76538|INF| 477|2022-05-03 17:36:10.964856| MAIN > Actual magnitude 10.0 - Recomputing AO params
WfsArbitrator_76538|DEB| 478|2022-05-03 17:36:10.965089| MAIN > computeAOsettings(): using table: /home/AOeng/live/aoroot/calib/wfs/current/ao/table_LUCIFER_ACE-AO.txt
WfsArbitrator_76538|INF| 479|2022-05-03 17:36:10.965949| MAIN > GOpt parameters taken from AO configuration table
WfsArbitrator_76538|DEB| 480|2022-05-03 17:36:10.981602| MAIN > Selected parameters:
WfsArbitrator_76538|DEB| 481|2022-05-03 17:36:10.981688| MAIN > HO binning : 1
WfsArbitrator_76538|DEB| 482|2022-05-03 17:36:10.981733| MAIN > HO ccdmode : 2
WfsArbitrator_76538|DEB| 483|2022-05-03 17:36:10.981773| MAIN > HO speed : 900 Hz
WfsArbitrator_76538|DEB| 484|2022-05-03 17:36:10.981811| MAIN > EM gain : 559
WfsArbitrator_76538|DEB| 485|2022-05-03 17:36:10.981846| MAIN > No. of modes: 501
WfsArbitrator_76538|DEB| 486|2022-05-03 17:36:10.981878| MAIN > Modal basis : KL_v20
WfsArbitrator_76538|DEB| 487|2022-05-03 17:36:10.981909| MAIN > REC matrix : 20190930_161000
WfsArbitrator_76538|DEB| 488|2022-05-03 17:36:10.981955| MAIN > TT amplitude: 3.0 l/d
WfsArbitrator_76538|DEB| 489|2022-05-03 17:36:10.981991| MAIN > TV binning : 4
WfsArbitrator_76538|DEB| 490|2022-05-03 17:36:10.982027| MAIN > TV speed : 4.3 Hz
WfsArbitrator_76538|DEB| 491|2022-05-03 17:36:10.982566| MAIN > Selected mag: 10.0
WfsArbitrator_76538|DEB| 492|2022-05-03 17:36:10.982616| MAIN > Flux : 27040

the variable MAG1 shows the current magnitude of the ocam

loaded disturbance 2.0 from adsecgui

optimize.

2.81,0.76,0.69

skip frame with HO2

gopt on

failed. process seems down

python_124983 |DEB| 1|2022-05-03 18:06:54.980928| MAIN > Connected as gopt.L
python_124983 |INF| 2|2022-05-03 18:06:58.934153| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 3|2022-05-03 18:07:03.132174| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 4|2022-05-03 18:07:07.285871| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 5|2022-05-03 18:07:11.601276| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 6|2022-05-03 18:07:15.813995| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 7|2022-05-03 18:07:19.989467| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 8|2022-05-03 18:07:24.222378| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 9|2022-05-03 18:07:28.302581| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 10|2022-05-03 18:07:32.562030| MAIN > Exception: need more than 2 values to unpack

optical gain restarted.

still KO.

restart optical diagnostic optical gain.

saving:20220503_180943

open loop

the gopt disturbance not loaded.

restart arbitrator.

python_124983 |DEB| 1|2022-05-03 18:06:54.980928| MAIN > Connected as gopt.L
python_124983 |INF| 2|2022-05-03 18:06:58.934153| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 3|2022-05-03 18:07:03.132174| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 4|2022-05-03 18:07:07.285871| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 5|2022-05-03 18:07:11.601276| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 6|2022-05-03 18:07:15.813995| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 7|2022-05-03 18:07:19.989467| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 8|2022-05-03 18:07:24.222378| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 9|2022-05-03 18:07:28.302581| MAIN > Exception: need more than 2 values to unpack
python_124983 |INF| 10|2022-05-03 18:07:32.562030| MAIN > Exception: need more than 2 values to unpack

restart wfs soft

Tue May 3 18:46:02.678 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[11] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 3 18:57:10.739 2022 aos.info - WFS source set to: FLAOWFS
Tue May 3 18:57:10.796 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue May 3 18:57:11.590 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

bitrator_81329|ERR| 271|2022-05-03 19:00:17.473587| MAIN > Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
WfsArbitrator_81329|DEB| 272|2022-05-03 19:00:17.474011| MAIN > arbFunc updateModulationInternal (, 'FLAOWFS', 'LUCIFER', 900)

restart wfs masterdiagnostic.

back to live again.

,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 3 19:03:47.228 2022 aos.info - WFS source set to: FLAOWFS
Tue May 3 19:03:47.290 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue May 3 19:03:47.984 2022 aos.info - FLAO: WFS: loading setup for LUCIF

optimize gain

3.7,0.10,0.1

gopt running.

optical gain ~0.4

TN: 20220503_191403

pause->skip->resume->loop open

TN:_192020

seeing 1.5

ue May 3 19:32:14.702 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[22] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 3 19:32:14.715 2022 aos.info - WFS source set to: FLAOWFS
Tue May 3 19:32:14.774 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Tue May 3 19:32:15.580 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

opt: 2.49,0.59,0.55

goptL0.47

tn:_193835

e May 3 19:41:14.108 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[26] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:12.5,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 3 19:41:14.127 2022 aos.info - WFS source set to: FLAOWFS
Tue May 3 19:41:14.258 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq750.00_sd3892.fits

opti

1.75,0.66,0.72

gopt

0.83,0.31,0.34

bin1/780Hz.

_195051

y:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Tue May 3 19:52:23.996 2022 aos.info - WFS source set to: FLAOWFS
Tue May 3 19:52:24.070 2022 aos.info - FLAO: WARNING: added atmospheric dist

Cancel preset.

Working on the Argos cal unit DX. It requires lights on.

Cancel the work for the day.

1:30PM stop

-- JuanCarlosGuerra - 03 May 2022
Topic revision: r2 - 04 May 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback