20220425_DX_Day DX AdSec Influence Function Data Collection with New 4D, Day 9

3:30 start. Amali and SX LBTI in parallel

03:40 Processing of yesterday's IF data sets
  • All 4D sets produced
  • The if_redux_new processed froze
    • last reading /local/aomeas/adsec_calib/4d/20220424_222431/121.4D
    • last Writting TT file for mode 346 to /local/aomeas/adsec_calib/tt/20220424_230712/tt_mode_346.dat
  • Killed the processes. Restart later

03:45 Align 4D. Restart later
  • Aligned

04:18 Guido sees some info for MMC
  • high forces on 484, 358, 114, 321
  • Ref Body Temp 4.2 C

04:22 Change DX from nighttime to daytime version
  • cd /home/aoeng/soul/mixed_mode_control/aoroot/calib/adsec/current
    • rm -r data
    • cp -r data.20220421.telescope data
  • cd /local/aomeas/adsec_calib/flat/Applicable
    • ln -fs ../20220422_191142/flattening_result.sav default.sav
  • cd /home/aoeng/soul/mixed_mode_control/aoroot/conf/adsec/current/TS3
    • cp bad_actuators.list.day bad_actuators.list
    • IDL> adsec_make_bad_act_files

04:30 bump 565 +150 nm

05:04 bump 367 +100 nm

05:14 flatten
  • print, opt_int_mat_reduce2(200, track='20220422_180622')
  • 0.574 w, 0.101 w rms (-0.13, 0.02)
  • shifted mask. Use to analyze 20220425_052400.mask

05:34 i4d_collect
  • old version so collect three set, 182, 191, 200
  • 20220425_173509
  • 20220425_173537

05:37 .compile and idl_collect
  • 06:22 Done with this set

06:24 idl_collect

Set 3

produce = ['20220425_173809','20220425_173846','20220425_173909','20220425_173940','20220425_174003','20220425_174026']

produce = ['20220425_174049','20220425_174116','20220425_174143','20220425_174210','20220425_174237','20220425_174304','20220425_174331','20220425_174358','20220425_174425','20220425_174452','20220425_174519','20220425_174546','20220425_174612','20220425_174639','20220425_174706','20220425_175759','20220425_175826','20220425_175853','20220425_175919','20220425_175946','20220425_180013','20220425_180040','20220425_180106','20220425_180133','20220425_180200','20220425_180227','20220425_180253','20220425_180320','20220425_180347','20220425_180413','20220425_180440','20220425_180506','20220425_180533','20220425_180600','20220425_180626','20220425_180707','20220425_180734','20220425_180801','20220425_180827','20220425_180854','20220425_180921','20220425_180947','20220425_181014','20220425_181041','20220425_181107','20220425_181134','20220425_181200','20220425_181227','20220425_181253','20220425_181320','20220425_181347','20220425_181413','20220425_181440','20220425_181507','20220425_181533','20220425_181653','20220425_181720','20220425_181747','20220425_181813','20220425_181840','20220425_181907','20220425_181933','20220425_182000','20220425_182027','20220425_182053','20220425_182120','20220425_182147','20220425_182213']

Set 4

produce = ['20220425_182443','20220425_182601','20220425_182623','20220425_182654','20220425_182716','20220425_182739','20220425_182802','20220425_182828','20220425_182855','20220425_182922','20220425_182949','20220425_183015','20220425_183042','20220425_183109','20220425_183135','20220425_183202','20220425_183229','20220425_183255','20220425_183322','20220425_183349','20220425_183415','20220425_183506','20220425_183533','20220425_183600','20220425_183627','20220425_183653','20220425_183720','20220425_183746','20220425_183813','20220425_183840','20220425_183906','20220425_183933','20220425_184000','20220425_184026','20220425_184053','20220425_184120','20220425_184146','20220425_184213','20220425_184240','20220425_184306','20220425_184333','20220425_184433','20220425_184459','20220425_184526','20220425_184553','20220425_184619','20220425_184646','20220425_184712','20220425_184739','20220425_184806','20220425_184833','20220425_184900','20220425_184927','20220425_184953','20220425_185020','20220425_185047','20220425_185113','20220425_185140','20220425_185207','20220425_185234','20220425_185300','20220425_185431','20220425_185458','20220425_185524','20220425_185551','20220425_185618','20220425_185645','20220425_185711','20220425_185738','20220425_185805','20220425_185831','20220425_185858','20220425_185925','20220425_185951']

['20220425_173421','20220425_173509','20220425_173537' ] 179-208

-- DougMiller - 25 Apr 2022
Topic revision: r5 - 30 Apr 2022, DougMiller