20220424_DX_Day DX AdSec IF data collection, Day 8

11:30 Arrive at LBTO

Restart DX AdSec in MMC configuration

08:14 change FF matrix
  • cd /home/aoeng/soul/mixed_mode_control/aoroot/calib/adsec/current
    • [AOeng@dxadsec current]$ cp data.20220421.telescope/* data/.
      • cp: omitting directory `data.20220421.telescope/flat'
    • [AOeng@dxadsec current]$ diff data/ff_list.fits data.20220421.telescope/.
    • [AOeng@dxadsec current]$ diff data/ff_list.fits data.20220411.lab/
      • Binary files data/ff_list.fits and data.20220411.lab/ff_list.fits differ
  • /local/aomeas/adsec_calib/flat/Applicable
    • [AOeng@dxadsec Applicable]$ ls -l default.sav
    • lrwxrwxrwx. 1 AOeng aoeng 53 Apr 22 23:07 default.sav -> ../20220420_181045/20220419_225059_bump_low_force.sav
    • [AOeng@dxadsec Applicable]$ ln -fs ../20220422_191142/flattening_result.sav default.sav
    • [AOeng@dxadsec Applicable]$ ls -l default.sav
      • lrwxrwxrwx. 1 AOeng aoeng 40 Apr 24 20:27 default.sav -> ../20220422_191142/flattening_result.sav
  • [AOeng@dxadsec TS3]$ cd /home/aoeng/soul/mixed_mode_control/aoroot/conf/adsec/current/TS3
    • [AOeng@dxadsec TS3]$ diff bad_actuators.list bad_actuators.list.night
    • [AOeng@dxadsec TS3]$ cp bad_actuators.list.day bad_actuators.list
    • [AOeng@dxadsec TS3]$ diff bad_actuators.list bad_actuators.list.day

08:43 Restart IDL, Fast, AdSec arb processes
  • All ok. Set Flat
  • % idl
  • IDL> @startup-onlycom
IDL SESSION SLAVE: only read permission allowed
Examining filename: /home/aoeng/soul/mixed_mode_control/aoroot/conf/adsec/672a/general/graph.txt
% Compiled module: DIST.
Projection matrix for forces not found: zero matrix will be used
Projection matrix for position not found: zero matrix will be used
Projection matrix for zernikes not found: zero matrix will be used
% READFITS: Now reading 672 by 672 array
% Conflicting or duplicate structure tag definition: FF_P_SVEC.
% Execution halted at: GETCONFTN          41
   /home/aoeng/soul/mixed_mode_control/aoroot/idl/adsec_lib/adsec_utilities/g
  etconftn.pro
%                      INIT_ADSEC        569
   /home/aoeng/soul/mixed_mode_control/aoroot/idl/adsec_lib/adsec/level3/init
  _adsec.pro
%                      $MAIN$          

09:51 flatten with 200 mode
  • 0.773 w 0.119 rms (-0.15, 0.05)
  • 20220424_215013
  • Ref Temp 3.6 C

10:02 i4d_collect
  • Upper flood lights on
  • return after first set
    • first set 20220424_220240
    • pause after 20220424_221132
      • print, hexalign(/apply)
    • pause 20220424_222129
      • print, hexalign(/apply)
    • pause 20220424_223111
      • no hexalign()
    • Last set 623-631 20220424_223701
    • Rest of TNs have same shape

10:41 remeasure 182-190, 191-199
  • 20220424_224241
  • 20220424_224315

10:43 Turn off upper lights
  • again 182-190, 191-199
  • 20220424_224532
  • 20220424_224500

10:47 hexalign

10:47 i4d_collect
  • 0-2 force (-0.146, 0.053)
  • 29-37 (-0.155, 0.045)
  • 65-73 (-0.160, 0.050)
  • 128-136 (-0.188, 0.060)
  • 191-199 vibration
  • 245-253 (-0.296, 0.172)
  • 299-307 (-0.325, 0.254)
  • 344-352 (-0.351, 0.329)
  • 389-397 (-0.336, 0.226)
  • 416-424 (-0.380, 0.255)
  • 461-469 (-0.391, 0.231)
  • pause 20220424_231512
    • hexalign()
  • 524-532 (-0.358, 0.215)
  • 560-568 (-0.376, 0.234)
  • 623-631 last 20220424_232215
  • Rest of TNs have same shape

11:24 hexalign

11:25 i4d_collect
  • 182-190 20220424_232430
  • 191-199 20220424_232507
  • 200-208 20220424_232534

11:26 Done!

11:40 Back to nighttime configuration, adsec_stop/start, Set, Rest
  • 1.02 w, 0.167 rms

  • Data Set 1
produce = [ '20220424_220240','20220424_220319','20220424_220341','20220424_220411','20220424_220434','20220424_220456','20220424_220519','20220424_220546','20220424_220612','20220424_220639','20220424_220706','20220424_220733','20220424_220759','20220424_220826','20220424_220852','20220424_220919','20220424_220946','20220424_221012','20220424_221039','20220424_221106','20220424_221132','20220424_221241','20220424_221308','20220424_221334','20220424_221401','20220424_221448','20220424_221515','20220424_221542','20220424_221608','20220424_221635','20220424_221702','20220424_221728','20220424_221755','20220424_221822','20220424_221849','20220424_221915','20220424_221942','20220424_222009','20220424_222035','20220424_222102','20220424_222129','20220424_222244','20220424_222311','20220424_222338','20220424_222404','20220424_222431','20220424_222457','20220424_222524','20220424_222551','20220424_222618','20220424_222645','20220424_222711','20220424_222738','20220424_222805','20220424_222831','20220424_222858','20220424_222925','20220424_222951','20220424_223018','20220424_223045','20220424_223111','20220424_223208','20220424_223235','20220424_223301','20220424_223328','20220424_223354','20220424_223421','20220424_223448','20220424_223514','20220424_223541','20220424_223608','20220424_223635','20220424_223701']

modes 632-647: not available '20220424_223728','20220424_223755'

  • Data Set 2
produce =  ['20220424_224241','20220424_224315','20220424_224500','20220424_224532','20220424_224755','20220424_224829','20220424_224852','20220424_224922','20220424_224944','20220424_225007','20220424_225029','20220424_225056','20220424_225123','20220424_225149','20220424_225216','20220424_225242','20220424_225309','20220424_225335','20220424_225402','20220424_225429','20220424_225455','20220424_225522','20220424_225549','20220424_225616','20220424_225642','20220424_225750','20220424_225817','20220424_225844','20220424_232430','20220424_232507','20220424_232534','20220424_230031','20220424_230058','20220424_230125','20220424_230151','20220424_230218','20220424_230244','20220424_230311','20220424_230337','20220424_230404','20220424_230430','20220424_230457','20220424_230523','20220424_230550','20220424_230617','20220424_230646','20220424_230712','20220424_230739','20220424_230805','20220424_230832','20220424_230859','20220424_230925','20220424_230952','20220424_231019','20220424_231045','20220424_231112','20220424_231139','20220424_231205','20220424_231232','20220424_231259','20220424_231326','20220424_231352','20220424_231419','20220424_231446','20220424_231512','20220424_231655','20220424_231722','20220424_231748','20220424_231815','20220424_231842','20220424_231908','20220424_231935','20220424_232002','20220424_232028','20220424_232055','20220424_232122','20220424_232148','20220424_232215']

modes 632-647: not available '20220424_232242','20220424_232308'

vibration from the elevator : '20220424_225910','20220424_225937','20220424_230004'

-- DougMiller - 24 Apr 2022
Topic revision: r6 - 27 Apr 2022, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback