20220422_DX_Day DX AdSec Flattening with New 4D, Day 7

Started at 6:45. RR on early

08:15 4D, DX AdSec aligned but pupil shifted

09:46 Pupil aligned

09:49 fsm_load_shape.pro modified by Guido and Xianyu

* all the changes are in $ADOPT_ROOT (/home/aoeng/soul/mixed_mode_control/aoroot) 09:57 copy the FF data
  • at calib/adsec/current
  • cp -r data data.20220411.lab

09:59 install the new ff data measured yesterday
  • cd /local/aomeas/adsec_calib/ff_matrix/20220421_165531/
  • cp *.fits /home/aoeng/soul/mixed_mode_control/aoroot/calib/adsec/current/data/
  • cd /home/aoeng/soul/mixed_mode_control/aoroot/calib/adsec/current/
  • cp -r data data.20220421.telescope

10:04 actuator list
  • cd /home/aoeng/soul/mixed_mode_control/aoroot/conf/adsec/current/TS3
  • bad_actuators.list.night is the one with more actuators removed for the night
  • bad_actuators.list.day is the one with less actuators removed for the day, this is for MMC
  • cp bad_actuators.list.day bad_actuators.list
  • idl to generate the new actuators list

10:17 default flat
  • the path is /local/aomeas/adsec_calib/flat/20220420_181045/20220419_225059_bump_low_force.sav

10:20 Stop IDL and FastDiagnostics and AdSec Arb processes
  • GUI Power ON
  • GUI Load Program
  • AdOpt> print, fsm_set_flat(/no_flat)
    • Actuator 21 was "slow" getting ready. high forces during set. stuck at 30 um. At 1:00 outer ring
AdSecArbitrator_94554|ERR|        95|2022-04-22 17:24:12.841346|        FASTDIAGN > [AOException] Error (Timeout error) in GetDiagnValue [2] (code -5001) Timeout error
  • print, fsm_rip()
  • print, fsm_set_flat(/no_flat)
    • act 21 behaved this time
  • flat looks reasonable

10:30 Full mask is 20220419_070400.mask
  • make smaller mask for lower order modes
  • AdOpt>print, i4d_opt_intmat(0,20,AMPRMS=100e-9)
    • 20220422_173324
    • IDL> print, idl_4d_produce('20220422_173324')
    • IDL> print, if_redux_new(/modal,'20220422_173324', /force)
    • IDL> print, build_int_mat(['20220422_173324'])
  • AdOpt> print, opt_int_mat_reduce2(20, track='20220422_173324')
    • /local/aomeas/adsec_calib/flat/20220422_174202/flattening_result.sav

10:44 Bigger but not full mask
  • modes 0-50 20220422_174406
  • AdOpt> print, opt_int_mat_reduce2(50, track='20220422_174406')
    • /local/aomeas/adsec_calib/flat/20220422_175932/flattening_result.sav
    • 8.3, 1.06 (-0.10 0.04)
  • print, hexalign(/apply)

11:06 Full mask (above name)
  • modes 0-50 20220422_180622
  • AdOpt> print, opt_int_mat_reduce2(50, track='20220422_180622')
    • /local/aomeas/adsec_calib/flat/20220422_182008/flattening_result.sav
    • 4.03 w 0.525 rms (-0.11 0.03)
  • print, hexalign(/apply)

11:23 Full mask (above name)
  • modes 51-100 20220422_182227
  • AdOpt> print, opt_int_mat_reduce2(100, track='20220422_180622')
    • /local/aomeas/adsec_calib/flat/20220422_184110/flattening_result.sav
    • 1.02 w 0.177 rms (-0.11 0.01)

11:23 Full mask (above name)
  • modes 101-200 20220422_184736
  • AdOpt> print, opt_int_mat_reduce2(200, track='20220422_18')
    • 2022040422_191142/flattening_result.sav
    • 0.527 w 0.0933 rms (-0.14 0.01) act 217, 216 @ -0.12

12:37 Test number affect of applied modes
  • all modes (632) 0.467 w 0.0902 rms (-0.14 0.03)
  • 500 0.497 w 0.0926 rms (-0.15 0.02)
  • 400 0.567 w 0.100 rms (-0.14 0.02)
  • 300 0.544 w 0.100 rms (-0.14 0.02)
  • 200 0.565 w 0.104 rms (-0.14 0.02)
  • 150 0.573 w 0.115 rms (-0.12 0.01)
  • 100 0.841 w 0.167 rms (-0.11 0.00)
  • 75 1.59 w 0.256 rms (-0.11 0.00)
  • 50 3.72 w 0.458 rms (-0.11 0.01)
  • 25 8.14 w 1.22 rms (-0.07 -0.01)

1:22 Number of modes as a function of elevation
  • 90 El 632 modes (-0.15 0.02)
  • 80 El 632 modes (-0.26 0.02) act 555 jumped a bit in positive direction
  • 70 El 303 modes (-0.3 0.02) act 216 @ -0.3
  • 60 El 187 modes (-0.3 0.02) act 216
  • 50 El 146 modes 216
  • 40 El 105 modes 216
  • 30.1 El 66 modes 216

1:37 Move to Zenith
  • (-0.17 0.13) act 216 @ 0.13
  • healign
  • 2.16 w 0.395 rms
  • flat with 66 modes
    • 1.84 w 0.315 rms (-0.10 0.00)

2:22 Put 555 in do not use position list. restart
  • 0.702 w 0.108 rms (-0.16 0.03) 216=-0.14 217=-0.16
  • bump actuators in center
    • 216 -50 (-0.09) -50 (-0.08) after 217, 216 is now (-0.07) (-0.09) -50 (-0.04)
    • 217 -50 (-0.14) -50 (-0.1) -50 (-0.06) after 216 (-0.08)
    • 104 -50 (-0.1) 216 (-0.06) 217 (-0.08)
    • save shape on GUI 20220422_214109/three_bumps.sav
    • apply flat 104 (-0.09) 216 (-0.05) 217 (-0.08)

2:44 Number of modes applied per elevation
  • 90 El 631 modes (-0.14 0.03)
  • 80 El 631 modes (-0.18 0.03) (104, 216, 217) (-0.06, -0.19, -0.12)
  • 70 El 501 modes (limit of -0.3) (-0.24, -0.3, -0.18)
  • 60 El 199 modes (-0.23, -0.29, -0.25)
  • 50 El 149 modes (-0.26, -0.3, -0.25)
  • 40 El 109 modes (-0.25, -0.3, -0.25)
  • 30.1 El 66 modes (-0.26, -0.3, -0.25)
  • back up to 50 EL (216 -0.13)
  • back up to 70 El (216 0.04)
  • back up to 90 El (216 0.13) (-0.17, 0.13)
  • reflatten at 90 El (-0.13 0.03)

Xianyu read header of .4D file
  • print,a1.MEASUREMENT.REMOVEDZERNIKETERMS._data
    • 1.7404331 1.7439206 -1.6624113 0.42379455 -0.0040125261 -0.042186029 -0.33536365 0.33884501 0.37157091

default flat path:/local/aomeas/adsec_calib/flat/20220420_181045/20220419_225059_bump_low_force.sav data.20220411.lab bad_actuators.list.night

4:23 Night configuration
  • 1.44 w 0.184 rms (-0.21 0.12) 115, 365 have hight force

-- DougMiller - 22 Apr 2022
Topic revision: r6 - 23 Apr 2022, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback