Details.

4:30 PM Power on

ocam not live.

check the system processes and masterdiagnostic offline.

Restart the process,

why it got disconnected.(?)

23:43:54.318004 MAIN > ------------------- STARTING MASTER DIAGNOSTIC SYSTEM --------------------
MasterDiagnostic_110702|INF| 48|2022-04-20 23:43:54.318032 MAIN > Real-time priority (99) succesfully set !
MasterDiagnostic_110702|INF| 49|2022-04-20 23:43:54.318047 MAIN > > STARTING OPTICAL LOOP DIAGNOSTIC...
MasterDiagnostic_110702|INF| 50|2022-04-20 23:43:54.318093 MAIN > > STARTING BCU39 FRAME DOWNLOADER...
MasterDiagnostic_110702|INF| 51|2022-04-20 23:43:54.318143 MAIN > > STARTING ADSEC STREAM FRAME DOWNLOADER...
MasterDiagnostic_110702|INF| 52|2022-04-20 23:43:54.319002 MAIN > Real-time priority (99) succesfully set !
MasterDiagnostic_110702|INF| 53|2022-04-20 23:43:54.319059 MAIN > Real-time priority (99) succesfully set !

Request restart bcu2k

reset operation mode to 1x1 cropped.

pop up: that it can be removed from the IDL.

didn;t come alive

power cycle bcu2k

after the restore of mode.

ocam not live

adsec master

0 11:26:07.183353|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_57540|ERR| 9917|2022-04-20 11:26:07.183890|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_2 HEADER:
MasterDiagnostic_57540|ERR| 9918|2022-04-20 11:26:07.183908|ADAPTIVE-SECONDARY > > FRAME BCU_MIRROR_1 HEADER:
MasterDiagnostic_57540|ERR| 9919|2022-04-20 11:26:07.183930|ADAPTIVE-SECONDARY > Detected a wrong filotto (BcuMirror _2 frame header don't match BcuMirror _3 header) !!!
MasterDiagnostic_57540|WAR| 9920|2022-04-20 11:26:07.183972|ADAPTIVE-SECONDARY > Wrong filotto. Frame skipped.
MasterDiagnostic_57540|INF| 9921|2022-04-20 11:26:10.658205| MAIN > OFramesHistory::dumpToFile: output file /local/aolog/2022/04/20/ADAPTIVE-SECONDARY_00001650453970_20220420_112610.bin
MasterDiagnostic_57540|INF| 9922|2022-04-20 11:26:10.658374| MAIN > Dumping 1st part of size 27764176...
MasterDiagnostic_57540|INF| 9923|2022-04-20 11:26:10.675085| MAIN > Dumping 2nd part of size 29599824...
MasterDiagnostic_57540|INF| 9924|2022-04-20 11:26:10.697849| ALERT-NOTIFIER > ArbitratorInterface to adsecarb.L succesfully created!
MasterDiagnostic_57540|INF| 9925|2022-04-20 11:26:10.697940| MAIN > Alert for dump to adsec arbitrator successfully sent

Reconfigure to bino-Luci

Preparing for OSCO.

6:30PM ocam cool down.

Thu Apr 21 02:25:12.466 2022 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[1283] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.125896[0.125896],roy:-0.194677,mag:7.48,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

elevation 55

some extra pickup noise in the CCD47.

source?

TT optimization RIP shell.

TT_optimize_20220421.png

pupil well aligned.

02:30:11.583495| MAIN > Received exception with code -10045
WfsArbitrator_90502|ERR| 281|2022-04-21 02:30:11.583763| MAIN > Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE
WfsArbitrator_90502|DEB| 282|2022-04-21 02:30:11.584376| MAIN > arbFunc doStopL

adsc_stop/start

Another preset.

move camera lens manually. to -14.9,-45.9.

The center pupil seems not computing the corrections....

Stop OSCO

adsecarb:

02:30:09.633263| ALERTHANDLER > Received an ERROR alert! Forcing Failure state.
AdSecArbitrator _57729|ERR| 4267|2022-04-21 02:30:09.633311| ALERTHANDLER > Alert message: COILS DISABLED from housekeeper.L

Housekeeper:

02:30:09.583476| FUNCTEMERGENCYSTOP > BCUCURRENTVCCP-0000 = 22.654 [Funct.cpp:95]
housekeeper_57646 |INF| 221711|2022-04-21 02:30:09.583523| ADAM-MODBUS > AdamModbus: disabling coils..

fastdiang.

02:30:09.285714| FUNCTWARNING > FunctWarning CHCURRAVERAGE-0569 -0.8

fastdiagn.L.202204210001.log:fastdiagn_57675 |ERR| 8662436|2022-04-21 02:30:09.463639| FUNCTALARM > FunctAlarm CHDISTRMS-0569 6.84411e-07

act569_20220421.png

plot_chcurraverage_20220421.png

continous with Bino mode.

11 PM No AO

power off the WFS.

actuator 440 showed to have the large current applied.

looking the box plot plot for all the actuators, it shows that the act 440 and 441 were dricving the large current.

act_chcurr.png

chcurraver_20220420.png

chditaver_20220420.png

Where are the 440, 441 and 439 act?, the 440 and 441 are in the inner ring.

map_440.png

act_inner.png

02:30:08.799212| MAIN > Adam in status: 1:1:0:0:0:1:1:1

adamHousekeeper_57460|INF| 723395|2022-04-21 02:30:08.815836| MAIN > Adam out status: 1:1:1:1:1:0:0:1

adamHousekeeper_57460|INF| 723396|2022-04-21 02:30:09.816176| FAST > Processed 1 cycles of 23 vars in 1.03 s ( 0.971 Hz). HW frame rate 10 [DiagnApp.cpp:832]

adamHousekeeper_57460|INF| 723397|2022-04-21 02:30:09.829222| MAIN > Adam in status: 1:1:0:0:1:1:1:1

adamHousekeeper_57460|INF| 723398|2022-04-21 02:30:09.847223| MAIN > Adam out status: 1:1:1:0:1:0:0:1

tcs_sys_fault activated.

adam output: coils disabled.

There is not an overcurrent signal in the BCUDigitalIOOvercurrent

-- JuanCarlosGuerra - 20 Apr 2022
I Attachment Action Size Date Who Comment
TT_optimize_20220421.pngpng TT_optimize_20220421.png manage 38 K 21 Apr 2022 - 02:58 JuanCarlosGuerra  
act569_20220421.pngpng act569_20220421.png manage 63 K 21 Apr 2022 - 03:04 JuanCarlosGuerra  
act_chcurr.pngpng act_chcurr.png manage 86 K 21 Apr 2022 - 06:35 JuanCarlosGuerra  
act_inner.pngpng act_inner.png manage 155 K 21 Apr 2022 - 17:05 JuanCarlosGuerra  
chcurraver_20220420.pngpng chcurraver_20220420.png manage 133 K 21 Apr 2022 - 06:44 JuanCarlosGuerra  
chditaver_20220420.pngpng chditaver_20220420.png manage 180 K 21 Apr 2022 - 06:44 JuanCarlosGuerra  
map_440.pngpng map_440.png manage 84 K 21 Apr 2022 - 17:03 JuanCarlosGuerra  
plot_chcurraverage_20220421.pngpng plot_chcurraverage_20220421.png manage 105 K 21 Apr 2022 - 03:43 JuanCarlosGuerra  
Topic revision: r4 - 21 Apr 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback