Staff:

LBTO: Juan Carlos, Barry and Josh.

Arcetri:NA

Summary.

Night plan

Tonight's plan can be found here:

https://wiki.lbto.org/Commissioning/Com20220418

Note that I've re-arraned the order of operations based on the NOAA weather predictions (which have been a lot more close to actual these last few nights than ALTA) and the current delta-T between mirror temps and ambient air. One LBC test requires a thermal gradient and this would assist with it (without forcing the change manually using mirror vent later). It also makes the instrument change a bit more efficient for end of night.

LBC-red will be starting "in the beam" - we can leave LUCI-1 in the beam as LBC-Blue is offliine. At 00:20 we'll reconfigure from LBC-Red to LUCI-2 on the right (leaving LUCI-1 still in the beam on the left).

Detail.

4:30 PM Power on

ocam cool down at 11:30PM

12:31AM reconfigure.

12:54 am osco preset.

guider-20220418.png

Adsec failure.

The ocam showed a not live for a second and the adsec went in failure.

2022-04-18 07:57:51.723444| Error

adsdc_stop/start

power on.

TSS activated. probably a wind gust above the limits.

elevation 65.

08:03:48.229925| MAIN > Maximum mode index used to apply flat -> # 553

1:06am seeing 0.77

3.7,

ncap on.

soul/aol

adsc_stop/start

adsec in failure.

07:57:55.139160| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]
fastdiagn.L.202204180000.log:fastdiagn_61040 |ERR| 4153976|2022-04-18 07:57:59.193124| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]

housekeeper.L.202204180000.log-housekeeper_53689 |ERR| 1117|2022-04-18 08:13:39.662949| MAIN > Error reading DSP [255-255] from BCU_SWITCH at address 0x0000102e (Switch BCU diagnostic variable): [RequestFaultException] The request has failed [HouseKeeper.cpp:2795]

housekeeper.L.202204180000.log:housekeeper_53689 |ERR| 1128|2022-04-18 08:13:40.762316| FUNCTEMERGENCYSTOP > BCUVOLTAGEVCCP-0000 = -0.0372838 [Funct.cpp:95]

08:13:43.532120| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]
fastdiagn.L.202204180000.log:fastdiagn_53710 |ERR| 82581|2022-04-18 08:13:47.582204| FUNCTEMERGENCYSTOP > emergencyReact = 1 [Funct.cpp:95]

gopt:

1.13,0.34,0.24

SR ~57%

modal SR ~80%

1st pos. telemetry w/ NCPA:

[telescope@obs1 ~]$ ./get_ao_telemetry

=> Command line arguements processed
Set 0 Tracknum 20220418_083035 LuciName unknown
Set 1 Tracknum 20220418_083047 LuciName unknown
Set 2 Tracknum 20220418_083059 LuciName unknown
-> wrote file /home/AOeng/doug/get_telemetry/OSCO/20220418_083035.log
telescope to Everyone (1:34 AM)
2nd pos. telemetry w/ NCPA:

[telescope@obs1 ~]$ ./get_ao_telemetry

=> Command line arguements processed
Set 0 Tracknum 20220418_083325 LuciName unknown
Set 1 Tracknum 20220418_083337 LuciName unknown
Set 2 Tracknum 20220418_083349 LuciName unknown
-> wrote file /home/AOeng/doug/get_telemetry/OSCO/20220418_083325.log

image luci1.*0033

luci_20220218_0032.png

01:47.preset 17.7

seeing 1.2"

tn:_20220418_084753

0.18,0.04,0

tn:_085009

0.23,0.09,0.0

_085153

loop open skip frame and loop opne

reclose with LNgain skip skip and stop AO

lost star.

1:56am send preset.

point check

no star in the CCD47.

guider FWHM0.8"

script of about 20minutes on sly. check robustness and stability of the AO

seeing 1.28"

gopt: 0.1,0.06,0.00

gopt ration: 0.04

tn:_090801

gopt_17p7_20220418.png

2:09 seeing 1.1"

_091209

large offset

09:14:50.843717| MAIN > offsetXY(): starting offset of -60.143, 58.960 mm
WfsArbitrator_173817|INF| 1324|2022-04-18 09:14:50.844525| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_173817|ERR| 1325|2022-04-18 09:14:50.844892| MAIN > RETRY: Offset outside FoV limits. Target xyz is -13

back ok.

lauch an optical loop data before the pause. pause large offset.

1336|2022-04-18 09:17:40.708940| MAIN > arbFunc doPauseLoop done.
WfsArbitrator_173817|DEB| 1337|2022-04-18 09:17:43.472882| MAIN > arbFunc offsetXYinternal (, 'FLAOWFS', 'LUCIFER', -74.823999999999998, 59.856699999999996, True)
WfsArbitrator_173817|INF| 1338|2022-04-18 09:17:43.473206| MAIN > offsetXY(): starting offset of -75.116, 59.490 mm
WfsArbitrator_173817|INF| 1339|2022-04-18 09:17:43.474201| MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
WfsArbitrator_173817|ERR| 1340|2022-04-18 09:17:43.474567| MAIN > RETRY: Offset outside FoV limits. Target xyz is -152.31 7.65 52.90 (-5002) VALUE_OUT_OF_RANGE_ERROR
WfsArbitrator_173817|DEB| 1341|2022-04-18 09:17:53.003341| MAIN > arbFunc doSaveStatus (, 'FLAOWFS', 'LUCIFER', '/l

_091751

2:20 seeing 1.4-1.5"

_092234

2:29 seeing 1.3"

faint17p7_20220418.png

2:29 new preset 17.1

mag 18

2.7 phot/subap

rerot out of range.

change rot angle

2.42,0.75,0.10

rms:0.9

optimize_mag18_20220418.png

gopt failed.

running wihtout gopt.

_094347

2:44 seeing 1.22"

modal_mag18_20220418.png

_095644

_095946

save only frames and ccd47

_100154

ccd47_mag18.png

3:09 seeing 1.1"

nebula.

bin2

3:24 am seeing 1.15

gopt:1.12,0.17,0.15

0.07

modal SR ~55-52%

tn:_102359

_102732,_102823

ccd47_nebula.png

running without NCPA.

It should have a better flag at the level of the FLAO GUI.

_105115

3:54am seeing 1.125"

nebulae.png

4:10 bino luci

the collimation star was very close to the PyWFs and it triggered the overillumination protection.

the wfs was in bin1 800Hz.

Reset the overcurrent protection.

4:25 TTM preset.

seeing 1"

moved to bin2

lngain ->rms0.7

tt:2.5,7,0.01

2.39,11.66,0.08

maybe to stop in one iter.

bin2 optimize gain TTM.

rms:0.67

_113232,_113502(catch a pause),_113539

_115656

stop AO

8|2022-04-18 12:00:31.189550| MAIN > Skip frame detected!
AdSecArbitrator_57729|INF| 2049|2022-04-18 12:00:31.927414| COMMANDHANDLER > FSM (status: AORunning) has received command 2024 (Save status)
AdSecArbitrator_57729|INF| 2050|2022-04-18 12:00:32.025925| COMMANDHANDLER > Command Save status (code 2024) successfully completed
AdSecArbitrator_57729|WAR| 2051|2022-04-18 12:00:32.204121| MAIN > Skip frame detected!
AdSecArbitrator_57729|INF| 2053|2022-04-18 12:00:35.146911| MAIN > Received cmd: StopAo (1)
AdSecArbitrator_57729|INF| 2054|2022-04-18 12:00:35.146977| COMMANDHANDLER > FSM (status: AORunning) has received command 2015 (Stop Ao)
AdSecArbitrator_57729|INF| 2055|2022-04-18 12:00:35.146998| SERIALIZATION > StopAoImpl (): restoreShape = 1
idl_57604 |INF| 1292|2022-04-18 12:00:35.147395| MAIN > fsm_stop_ao start

12:00:35.487432| MAIN > Commands out of safe range ID: # 4
idl_57604 |INF| 1298|2022-04-18 12:00:35.487475| MAIN > Forces out of safe range ID: # 29 # 40 # 41 # 44 # 45 # 46 # 53 # 54 # 56 # 57 # 63 # 64 # 66 # 75 # 82 # 83 # 89 #110 #111 #112 #138
idl_57604 |INF| 1299|2022-04-18 12:00:35.487494| MAIN > SafeSkipFrames caused by commands out of range detected.
idl_57604 |INF| 1300|2022-04-18 12:00:35.487516| MAIN > SafeSkipFrames caused by forces out of range detected.
idl_57604 |INF| 1301|2022-04-18 12:00:35.487534| MAIN > Recovery from any SafeSkipFrames started...

12:00:39.588708| MAIN > Maximum mode index used to apply flat -> # 635

2022-04-18 12:00:46.566947| COMMANDHANDLER > Command Stop Ao (code 2015) successfully completed
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > Cannot dispatch alert: Outgoing.cpp:493: Ice::UnknownException:
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . unknown exception:
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . Traceback (most recent call last):
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . File "aoarbitrator.py", line 185, in alert
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . self._loop._fsm.SkfAlert()
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . File "/home/aoeng/live/aoroot/lib/python/AOArb_sm.py", line 612, in trans_sm
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . getattr(self.getState(), attrib)(self, *arglist)
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . File "/home/aoeng/live/aoroot/lib/python/AOArb_sm.py", line 437, in SkfAlert
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . fsm.getState().Exit(fsm)
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . File "/home/aoeng/live/aoroot/lib/python/statemap.py", line 104, in getState
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . raise StateUndefinedException
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > . StateUndefinedException
AdSecArbitrator_57729|WAR| 2065|2022-04-18 12:00:46.596814| MAIN > .
AdSecArbitrator_57729|WAR| 2066|2022-04-18 12:00:47.771540| MAIN > Skip frame detected!
AdSecArbitrator_57729|INF| 2067|2022-04-18 12:00:54.843839| ALERTHANDLER > Received from masterdiagnostic.L a DumpSaved alert with filename /local/aolog/2022/04/18/ADAPTIVE-SECONDARY_00001650283254_20220418_120054.bin
AdSecArbitrator_57729|INF| 2068|2022-04-18 12:00:54.843885| ALERTHANDLER > Processdump is skipped
20221804 12:00:54.8447 Alert: DumpSaved: DumpSaved vector ready

5:00am stop

-- JuanCarlosGuerra - 17 Apr 2022
I Attachment Action Size Date Who Comment
ccd47_mag18.pngpng ccd47_mag18.png manage 56 K 18 Apr 2022 - 10:08 JuanCarlosGuerra  
ccd47_nebula.pngpng ccd47_nebula.png manage 36 K 18 Apr 2022 - 10:35 JuanCarlosGuerra  
faint17p7_20220418.pngpng faint17p7_20220418.png manage 292 K 18 Apr 2022 - 09:30 JuanCarlosGuerra  
gopt_17p7_20220418.pngpng gopt_17p7_20220418.png manage 196 K 18 Apr 2022 - 09:08 JuanCarlosGuerra  
gopt_20220418_17p7.pngpng gopt_20220418_17p7.png manage 1 MB 18 Apr 2022 - 09:06 JuanCarlosGuerra  
guider-20220418.pngpng guider-20220418.png manage 133 K 18 Apr 2022 - 07:55 JuanCarlosGuerra  
luci_20220218_0032.pngpng luci_20220218_0032.png manage 370 K 18 Apr 2022 - 08:38 JuanCarlosGuerra  
modal_mag18_20220418.pngpng modal_mag18_20220418.png manage 142 K 18 Apr 2022 - 09:46 JuanCarlosGuerra  
nebulae.pngpng nebulae.png manage 365 K 18 Apr 2022 - 11:22 JuanCarlosGuerra  
optimize-18_20220418.pngpng optimize-18_20220418.png manage 1 MB 18 Apr 2022 - 09:42 JuanCarlosGuerra  
optimize_mag18_20220418.pngpng optimize_mag18_20220418.png manage 218 K 18 Apr 2022 - 09:45 JuanCarlosGuerra  
Topic revision: r4 - 18 Apr 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback