power up.

OCAM not live.

Power cycle bcu2k.

OK.

Argos Cal unit error to deply the arm.

argos_cal_unit_notavialble_20220415.png

two reset activated and clean up the errors..

Test preset.

Fri Apr 15 19:29:44.733 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[729] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Close loop from FLAO gui

22-04-15 19:34:57.769539| MAIN > Received cmd: LoadDisturbTag("/local/aomeas/adsec_calib/M2C/KL_v20/disturb/CmdDisturb_20220415_192945.fits)
AdSecArbitrator_65993|INF| 1374|2022-04-15 19:34:57.769604| MAIN > Compare: 0
AdSecArbitrator_65993|INF| 1375|2022-04-15 19:34:57.769638| MAIN > Tag: /local/aomeas/adsec_calib/M2C/KL_v20/disturb/CmdDisturb_20220415_192945.fits
AdSecArbitrator_65993|INF| 1376|2022-04-15 19:34:57.769701| SERIALIZATION > > disturbActive: ON
AdSecArbitrator_65993|INF| 1379|2022-04-15 19:34:57.769834| COMMANDHANDLER > FSM (status: AOSet) has received command 2019 (Set disturb)
Last message repeated
AdSecArbitrator_65993|INF| 1380|2022-04-15 19:34:57.769857| SERIALIZATION > > disturbActive: ON
idl_65876 |INF| 987|2022-04-15 19:34:58.616163| MAIN > ------------------------ ENABLING NOISE ADDING --------------------------
idl_65876 |INF| 988|2022-04-15 19:34:58.620058| MAIN > ------------------------ DONE --------------------------
AdSecArbitrator_65993|INF| 1384|2022-04-15 19:34:58.620247| COMMANDHANDLER > Command Set dis

optimize.

skip frame HO1.

optimize_nodist_20220415.png

gopt running

save TN: 20220415_193835

set gain zero.

save tn: _193940

restore gain.

_194013

10000 frames stated before gain zero and reply gain just at the end.

tn:_194117

Doing Pause from Adsec the WFS stil close loop

pause adsec

save tn: _194228

resume Adsec restore the previous gain.

Start save->Pause adsec(gain zero )->resume(gain restore)

TN:_194342

StopAO

Preset.

close loop from FLAO loads the disturbance.

optimize

gain zero save data.

tn:-195155

save before gian zero.

tn:_195338

reduce gain:

tn:-195752

low tt high HO1,2

_195931

some skip frames after misalign the rerot.

skip, save, gain zero

tn:-202110

bin2 pupil check.

pupil file: 20211125_011619

load the pupil manually using the change_ocam.py 3

power on LFBG rotator.

pupil wobble OK

bin2_20220415_pupil_20211125.png

cp ao tables ace and TT to

-rw-rw-r--. 1 AOeng AOeng 9974 Apr 15 20:38 table_LUCIFER_ACE-AO.txt.20220415
-rw-r--r--. 1 AOeng AOeng 5930 Apr 15 20:41 table_LUCIFER_TTM-AO.txt.20220415

33 Apr 15 20:45 table_LUCIFER_TTM-AO.txt -> table_LUCIFER_TTM-AO.txt.20220415
lrwxrwxrwx. 1 AOeng AOeng 33 Apr 15 20:45 table_LUCIFER_ACE-AO.txt -> table_LUCIFER_ACE-AO.txt.20220415

test preset bin2.

Fri Apr 15 20:46:41.109 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[740] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

center pupils ->ok.

Fri Apr 15 20:49:27.574 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[742] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

center pupil ->ok

optimize values no dist.

no skip

Fri Apr 15 20:55:59.230 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[746] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:14,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Apr 15 20:55:59.244 2022 aos.info - WFS source set to: FLAOWFS
Fri Apr 15 20:55:59.303 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits
Fri Apr 15 20:56:00.345 2022 aos.info - FLAO: WFS: loading setup for LUCIFE

star in the ccd47 but the acquire didn't get it.

preset again.

optimize gain values:

8.8,11.52,0.08

optimize_tt_bin2_seeing1_20220415.png

3866| MAIN > HO1: range 0.10 - 3.00
WfsArbitrator_45765|INF| 1050|2022-04-15 21:04:50.624262| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_45765|INF| 1051|2022-04-15 21:04:56.284572| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_45765|INF| 1052|2022-04-15 21:05:05.027210| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_45765|INF| 1053|2022-04-15 21:05:16.631920| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.850000)
WfsArbitrator_45765|INF| 1054|2022-04-15 21:05:34.306415| MAIN > HO minimum was not deep enough, forcing iteration (threshold is 0.85000

bin4

shutter 50

Fri Apr 15 21:09:08.866 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[753] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Apr 15 21:09:08.887 2022 aos.info - WFS source set to: FLAOWFS
Fri Apr 15 21:09:08.976 2022 aos.info - FLAO: WARNING: added atmospher

RY negative

diagonal bottonn left to upper right.

skip frame just at the beginning.

199|2022-04-15 21:15:15.429853| MAIN > Starting gain optimization procedure
WfsArbitrator_45765|INF| 1200|2022-04-15 21:15:15.454193| MAIN > Starting autogain, TN=20220415_211515
WfsArbitrator_45765|INF| 1201|2022-04-15 21:15:15.466494| MAIN > TT: range 0.05 - 3.10
WfsArbitrator_45765|INF| 1202|2022-04-15 21:15:20.268669| MAIN > Received exception with code -10045
WfsArbitrator_45765|ERR| 1203|2022-04-15 21:15:20.268969| MAIN > Safe skip active - cannot proceed (-10045) IDL_SAFE_SKIP_ACTIVE

TN: 20220415_211555

with high flux: mag 14.5

load manula gains:

0.9,0.35,0.05

rms->0.5

tn:_211834

stopao

Fri Apr 15 21:21:33.947 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[755] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Apr 15 21:21:33.959 2022 aos.info - WFS source set to: FLAOWFS
Fri Apr 15 21:21:34.016 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits
Fri Apr 15 21:21:34.742 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

the disturbance is loaded any way for TTM

Better to do the optimize gain manually...

back to bin1

Fri Apr 15 21:32:14.564 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[760] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Fri Apr 15 21:32:14.582 2022 aos.info - WFS source set to: FLAOWF

skipping frame and gain to 10modi

tn:213836

skipping and gain zero

tn:213930

skip frame 100

stop ao doen;t work.

open loop from WFS

some TN saved to check: 214040

2:48 handover

-- JuanCarlosGuerra - 15 Apr 2022
Topic revision: r1 - 15 Apr 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback