summary.

close loop check and pupils checks.Test swap pause sequence and bin3 performances using the three disturbance and collect the gains applied.

Details.

power on.

timeoutbcu2k.

oca frame ok.

test preset.

Thu Apr 7 16:08:38.506 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[681] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Thu Apr 7 16:10:31.810 2022 aos.info - FLAO: Adsec 672b-left loading reconstructor.
Thu Apr 7 16:10:40.002 2022 aos.AcquireRef{FLAO}.failed - AcquireRef{FLAO}[682] - [AOException] centerPupils: WARNING - RETRY: Camera lens temperature too low. T= 5.44, minimum allowed is 7.00 (0) NO_ERROR

temperaturewfs_20220407.png

bin1 pupil rotation.

pupils: 20211210_210322

rot@341: x=23 y=57

ok

bin1_20220407.png

Restart the AOS to allow new entries in the fields

bin3 pupil rotation.

argos shutter:52

set mag mag:16

Thu Apr 7 16:49:11.587 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[1] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

dark:alibFile(): saved as 20220407_164954

pupil:20220119_035330

rot@341 x~48, y~37

bin3_20220407.png

bin4 pupil rotation.

Thu Apr 7 17:12:30.221 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[3] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:16.6,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

rot@342, x=72,y=55

pupil:20211205_144238

bin4_20220407.png

close loop check Bin1

Thu Apr 7 17:37:01.208 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[5] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 17:37:01.228 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 17:37:01.289 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Thu Apr 7 17:37:02.106 2022 aos.info - FLAO: WFS: loading setup for LUCIFE

rot 360

PSF

1.91,0.54,0.53

gopt on

TN:_20220407_175123

TN+luci:_175341

Image quality is not good, also it is appreciated in teh modes display

Thu Apr 7 17:57:16.316 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[12] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 17:57:16.331 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 17:57:16.393

opt gain:

1.91,0.53,0.52

Modes display shpws a good correctiop. but the optical loop data can not saved.

_starting to take data and for just a second the WFS went offline, detach the arbitrator..?

OptLoopDiagnostic_105937|DEB| 15|2022-04-07 18:03:11.30843 ARB-INTERFACE > SerializableMessageSender for succesfully created!
OptLoopDiagnostic_105937|INF| 16|2022-04-07 18:03:11.30844 ARB-INTERFACE > ArbitratorInterface to adsecarb.L@M_ADSEC succesfully created!
OptLoopDiagnostic_105937|WAR| 17|2022-04-07 18:03:11.30848 GET_RAW_DATA > Error reading shared buffer: This operation requires previous initialization - trying to reattach [AdsecDiagnLib.cpp:144]

The optical loop data is not saviong anything..

MasterDiagnostic_39300|WAR| 20508|2022-04-07 18:06:42.900206| BCU39 > FramesDownloader BCU39: packet successfully ignored !
MasterDiagnostic_39300|WAR| 20509|2022-04-07 18:06:42.900274| BCU39 > FramesDownloader BCU39: [InvalidDiagnosticPacketException] Unexpected packetId 14 for frameId 408 (instead of packetId 0 for frameId 408)
MasterDiagnostic_39300|WAR| 20510|2022-04-07 18:06:42.900308| BCU39 > FramesDownloader BCU39: packet successfully ignored !

Restart WFS software.

Thu Apr 7 18:12:43.737 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[16] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 18:12:43.753 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 18:12:43.801 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq1000.00_sd3892.fits
Thu Apr 7 18:12:44.720 2022 aos.info - FLAO: WFS: loading setup

TN+luci:20220407_182003

stop the preset, looking a the modal plot looks like a bad correction.

the ao table shows the 1.2 changed to 900

a much better gain optimization....

optimization_900.png

TN=Luci:_183247,_183514

psf_20220407_183247.png

bin3 preset.

shutter 48, preset mag 15.8

Thu Apr 7 18:38:31.410 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[22] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 18:38:31.426 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 18:38:31.484 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq200.0000_sd3892.fits
Thu Apr 7 18:38:32.311 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

estimated mag->16.1

tn+luci:_184312,_184434(cube20)

modal SR~42%

bin3_optimize_20220407.png

change to J

_184755

loop pause.

luci dark:20220407.0009

Thu Apr 7 18:49:59.582 2022 aos.Pause{FLAO}.complete - Pause{FLAO}[680]

Thu Apr 7 18:53:56.807 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[28] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 18:53:56.828 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 18:53:56.894 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s2.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits

gain with three turbulance seeing.

modal SR ~30%

gop gain:0.48,0.16,0.02

_185841,_185946

pause

_190119

Thu Apr 7 19:03:17.011 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[34] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 19:03:17.028 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 19:03:17.083 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.5_L040.0_v15.0_ovfreq500.0000_sd3892.fits
Thu Apr 7 19:03:17.874 2022 aos.info - FLAO: WFS: loading setup for LUCIFER

optimize:3.03,1.33,0.10

gopt: 0.55,0.24,0.03

modal Sr ~46

_190816,_190920

bin3_optimize_20220407.png

Thu Apr 7 19:11:50.597 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[38] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:15.8,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)
Thu Apr 7 19:11:50.615 2022 aos.info - WFS source set to: FLAOWFS
Thu Apr 7 19:11:50.670 2022 aos.info - FLAO: WARNING: added atmospheric disturbance file dist_flao2_KL_v20_atm_s1.0_L040.0_v15.0_ovfreq500.0000_sd3892.fits
Thu Apr 7 19:11:51.494 2022 aos.info - FLAO: WFS: loading setup for LUCIFE

opti ize: 2.57,0.86,0.10

gopt:

rms:0.8, with gopt->2.4

_191708,_191826

modal SR~55%

test swap commands

Thu Apr 7 19:22:24.754 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[43] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

close loop

pause from AOS

Thu Apr 7 19:27:15.613 2022 aos.Pause{FLAO}.complete - Pause{FLAO}[680]
Thu Apr 7 19:27:22.305 2022 aos.Resume{FLAO}.started - Resume{FLAO}[680]
Thu Apr 7 19:27:22.465 2022 aos.info - AO loop closed
Thu Apr 7 19:27:22.465 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[680]

TN:_192711

Brandon connected....

install the new arbitrator restartted for the swap.

Thu Apr 7 19:30:41.996 2022 aos.PresetAO{FLAO}.started - PresetAO{FLAO}[49] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0[0],roy:0,mag:11,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Thu Apr 7 19:35:16.985 2022 aos.Pause{FLAO}.started - Pause{FLAO}[680]
Thu Apr 7 19:35:17.384 2022 aos.info - AO loop closed
Thu Apr 7 19:35:17.385 2022 aos.Pause{FLAO}.complete - Pause{FLAO}[680]
Thu Apr 7 19:35:22.932 2022 aos.Resume{FLAO}.started - Resume{FLAO}[680]
Thu Apr 7 19:35:23.384 2022 aos.info - AO loop closed
Thu Apr 7 19:35:23.385 2022 aos.Resume{FLAO}.complete - Resume{FLAO}[680]

TN:_193513

Thu Apr 7 19:38:42.848 2022 aos.Pause{FLAO}.started - Pause{FLAO}[680]
Thu Apr 7 19:38:43.162 2022 aos.info - AO loop closed
Thu Apr 7 19:38:43.162 2022 aos.Pause{FLAO}.complete - Pause{FLAO}[680]
Thu Apr 7 19:38:50.372 2022 aos.Resume{FLAO}.started - Resume{FLAO}[680]
Thu Apr 7 19:38:50.572 2022 aos.info - AO loop closed

TN:_193839

handover. 12:49

-- JuanCarlosGuerra - 07 Apr 2022
I Attachment Action Size Date Who Comment
bin1_20220407.pngpng bin1_20220407.png manage 67 K 07 Apr 2022 - 16:56 JuanCarlosGuerra  
bin3_20220407.pngpng bin3_20220407.png manage 74 K 07 Apr 2022 - 17:16 JuanCarlosGuerra  
bin3_optimize_20220407.pngpng bin3_optimize_20220407.png manage 225 K 07 Apr 2022 - 18:49 JuanCarlosGuerra  
bin3_seeing1p5_20220407.pngpng bin3_seeing1p5_20220407.png manage 145 K 07 Apr 2022 - 19:10 JuanCarlosGuerra  
bin4_20220407.pngpng bin4_20220407.png manage 75 K 07 Apr 2022 - 17:38 JuanCarlosGuerra  
optimization_900.pngpng optimization_900.png manage 634 K 07 Apr 2022 - 18:32 JuanCarlosGuerra  
psf_20220407_183247.pngpng psf_20220407_183247.png manage 48 K 07 Apr 2022 - 18:36 JuanCarlosGuerra  
temperaturewfs_20220407.pngpng temperaturewfs_20220407.png manage 168 K 07 Apr 2022 - 16:14 JuanCarlosGuerra  
Topic revision: r2 - 08 Apr 2022, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback